Laserfiche WebLink
N <br /> O <br /> O <br /> AIR DISTRIBUTION AND PIPING DESIGN CRITERIA EXHAUST FAN SCHEDULE o <br /> TAG EF-1 <br /> DUCT TYPE MAXIMUM PRESSURE DROP MAXIMUM VELOCITY LOCATION GROUND LEVEL <br /> [IN WC/100',UNO] [FPM] NOTES MANUFACTURER COOK <br /> MODEL NO. 195TCNHBLE19 <br /> GENERAL EXHAUST 0.1 1,500 TYPE BELT <br /> AREAS SERVED MATERIAL STORAGE <br /> NOTES: RETURN EXHAUST TAN IS) <br /> MATERIAL STORAGE AIRFLOW(CFM) 1,225 <br /> BYPASS AIRFLOW(CFM) 5,775 <br /> TOTAL AIRFLOW(CFM) 71000 <br /> SUPPLY DUCT RETURN/EXHAUST DUCT EFFECTNE PLUME HEIGHT(R) 30.4 <br /> SYSTEM PRESSURE CLASS PRESSURE CLASS INSULATION APPLICATION[3] MATERIAL [2]PRESSURE TEST REQUIRED TIP(Nj[t] is <br /> [IN wc][1] [IN wc][i] N <br /> FAN RPM 1916 0 <br /> GENERAL EXHAUST FAN +2` -2" NO STAINLESS NO DRIVE BELT <br /> FUME HOOD +2° -2" NO STAINLESS NO FAN TYPE BACKWARDS INUNE <br /> MOTOR TYPE TEFC-PE <br /> MOTOR QUANTITY X HP 1 0 7.5 <br /> TOTAL BHP 5.62 <br /> NOTES: VARIABLE SPEED DRIVE YES <br /> 1. PRESSURE CLASS BASED ON SMACNA STANDARDS. <br /> 2. INDICATES IF PRESSURE TEST IS TO BE PERFORMED,OR AS INDICATED. PRESSURE TEST TO CONFORM WITH SMACNA STANDARDS. LIGHT TEST TO CONFORM WITH CODE. ELECTRICAL DATA <br /> 3. REFERENCE MATERIAL INSULATION MATRIX FOR INSULATION R-VALUE,VAPOR BARRIER,ETC. MATERIAL MATRIX TAKES PRECEDENCE OVER THIS SCHEDULE. VOLT/PHASE 460/3 r <br /> POWER NORMAL :2 <br /> STARTER VFD <br /> FURNISHED/INSTALLED MC/EC a <br /> DISCONNECT BY EC O <br /> FURNISHED/INSTALLED MC/EC LL <br /> GRILLE, REGISTER AND DIFFUSER SCHEDULE o <br /> EQUIP. SERVICE MANUFACTURER MODEL DESCRIPTION CONTROLS-REF ONLY <br /> NORMAL MODE AUTO vY <br /> ID NO. STYLE MATERIAL FRAME FRAME MODEL FACE SIZE NECK SIZE MAX CFM BRANCH DUCT NC COLOR NOTES CONTROLS BY STAND ALONE =' <br /> C2 RETURN GRILLE PRICE INDUSTRIES BO EGGCRATE ALUMINUM LAY-IN BORDER TYPE 3 24x24 22X22 1200 PER PLAN <12 WHITE <br /> PHYSLE GN TH(N)[21 54 _ z aaaaaaa <br /> NOTES: WIDTH(IN)[21 42 <br /> HEIGHT(IN) 120 <br /> OPERATING WEIGHT(LBS) 737 <br /> SOUND LEVEL(dBA) 81 <br /> ACCESSORIES N <br /> SMOKE DETECTOR[31 NA <br /> 'FURNISH/INSTALL/WIRE EC/EC/EC a <br /> CONTROLS STANDALONE <br /> MIXING BOX WITH INTEGRAL DAMPERS YES x <br /> W <br /> NOTES: uj <br /> 1. TOTAL STATIC PRESSURE SHALL INCLUDE INTERNAL COMPONENTS. 0 <br /> 2. DIMENSION DOES NOT INCLUDE INLET OR OUTLET COWUNG DIMENSIONS. a <br /> 3. SMOKE DETECTOR NOT REQUIRED PER WSMC SECTION 606.2.1,EXCEPTION 2. <br /> Q co <br /> o N aV <br /> E J U) <br /> Z � <br /> o W a nLU <br /> LU <br /> o = C o�LU 3 <br /> d C d O <br /> Ln <br /> Lu <br /> v J O <br /> Q u <br /> E W U <br /> m = E <br /> u <br /> Lu <br /> U <br /> Q <br /> U <br /> Q s F <br /> sn <br /> j 0, <br /> fSS/ONAL ECG <br /> Drawn By UMC <br /> Checked By RAG <br /> i <br /> _egol <br /> a THIS DRAWING AND THE DESIGN Original Issue Date 09/06/2024 <br /> U n HEREIN ARE THE PROPERTY OF <br /> UNIVERSITY MECHANICAL Job No. 9386 <br /> 'aaCONTRACTORS,INC.FOR THEIR <br /> a CONSTRUCTIONE IN Scale AS SHOWN <br /> PROJECT.NO OTHER USE SHALL <br /> BE PERMITTED WITHOUT THE Sheet No. <br /> w N WRITTEN CONSENT OF UNIVERSITY M1.01 <br /> o m MECHANICAL CONTRACTORS,INC. <br /> N <br /> A\ <br />