Installation <br /> (for qualified installers only) <br /> Rear Vent Configuration with Horizontal Termination <br /> • Use the rear vent conversion from Travis Industries (SKU 94400998). <br /> • Use 8" Diameter Vent <br /> • Horizontal sections require a '/4" (6mm) rise every 12" (305mm) of travel. <br /> • A maximum of three (3) elbows (30°, 45°, 60' or 90°) may be used. Of these elbows, only one (1) <br /> may be a horizontal elbow (see illustration). <br /> • The termination must fall within the shaded area shown in the chart. Use the indicated restrictor <br /> position. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may vary <br /> slightly, especially when the termination is near a demarcation line. <br /> • Diffuser must be closed (see page 16). <br /> E <br /> E E � C9 <br /> x <br /> is <br /> a� a� ? a? E <br /> o Lo Zo <br /> Exhaust Restrictor Position#5 0 `n <br /> Exhaust Restrictor Extender Installed <br /> 12 feet max(3.6m) — —12 feet max(3.6m) <br /> 10 feet(3m) — \�\\._ —10 feet(3m) <br /> Exhaust Restrictor Position#3 — <br /> Exhaust Restrictor Extender Installed - <br /> 5 feet(1.5m) — �— — 5 feet(1.5m) <br /> Exhaust Restrictor Removed <br /> Min. 1' (0.3m)Vertical Section Required <br /> - O — <br /> 0 feet- I I I I I I I —0 feet <br /> iv <br /> LO CO LO w <br /> o <br /> a� <br /> m m X <br /> ,2 o E <br /> `n LO ifl <br /> Horizontal Elbow <br /> Horizontal elbows are elbows placed between <br /> two horizontal sections of pipe. One 30°, 45°, 60°or 90° <br /> horizontal elbow is allowed for this configuration. <br /> ©Travis Industries 4/19/23- 1443 Greenfield GSR2 <br />