Laserfiche WebLink
Installation24 <br /> Vent Termination Requirements (see illustration below) <br /> ! Venting terminals shall not be recessed into a wall or siding. <br /> A Minimum 9"(229mm)clearance from any door or window <br /> B Minimum 12" (305mm)above any grade, veranda, porch, deck or balcony Roof <br /> Surface <br /> C Minimum 1"(25mm)from outside corner walls <br /> NOTE: Clearance in accordance with local installation codes and the requirements Roof <br /> of the gas supplier. 11"Min. Eaves <br /> D Minimum 1"(25mm)from inside corner walls (279mm) 6°Min. <br /> NOTE: Clearance in accordance with local installation codes and the requirements (152mm) <br /> of the gas supplier. up <br /> E Minimum 11" (279mm)clearance below unventilated soffits or roof surfaces <br /> Minimum 18" (457mm)clearance below ventilated soffits <br /> Minimum 6"(152mm)clearance below roof eaves <br /> NOTE:Vinyl surfaces require 24"(610mm) <br /> NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. <br /> F Minimum 12" (305mm)clearance below a veranda, porch, deck or balcony <br /> NOTE: Permitted only if veranda, porch, deck, or balcony is fully open on a minumum of two sides beneath the floor. <br /> NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. <br /> G Minimum 48"(1219mm)clearance from any adjacent building <br /> H Minimum 84" (2134mm)clearance above any grade when adjacent to public walkways or driveways <br /> NOTE: may not be used over a walkway or driveway shared by an adjacent building <br /> I Minimum 9" (229mm)clearance to any nonmechanical air supply inlet to the building or the combustion air inlet <br /> to any other appliance. <br /> J Minimum 36" (914mm)clearance above any mechanical air supply inlet if within 10' (3M)horizontally <br /> K Minimum 36" (914mm)from the area above the meter/regulator (vent outlet) -this extends 15' (4.5M)above the <br /> regulator <br /> NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. <br /> L Minimum 36" (914mm)from the meter/regulator(vent outlet) <br /> NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. <br /> M Minimum 12"(305mm)above the roof line(for vertical terminations) <br /> N Minimum 24"(610mm)horizontal clearance to any surface(such as an exterior wall)—for vertical terminations <br /> \ E <br /> N <br /> M <br /> E <br /> E <br /> — Af } <br /> K = IJ <br /> G F = A I � 0 0 H <br /> C <br /> D II . <br /> Lf <br /> B <br /> NOTE: Measure clearances to the nearest edge of the exhaust hood. <br /> • Use the vinyl siding standoff when installing on an exterior with vinyl siding. <br /> • Vent termination must not be located where it will become plugged by snow or other material <br /> ©Travis Industries 4/19/23- 1443 Greenfield GSR2 <br />