My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
906 SE EVERETT MALL WAY 110 EVERETT MALL OFFICE PARK 2025-09-26
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
EVERETT MALL OFFICE PARK
>
906 SE EVERETT MALL WAY 110 EVERETT MALL OFFICE PARK 2025-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2025 1:16:07 PM
Creation date
1/30/2025 2:26:36 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Unit
110
Tenant Name
EVERETT MALL OFFICE PARK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2021 WSEC-C DUCT INSULATION SCHEDULE GRILLE,REGISTER,&DIFFUSER SCHEDULE <br /> DUCT TYPE INSULATION TYPE MIN.R-VALUE CALLOUT DESCRIPTION AIRFLOW RANGE,CFM FACE SIZE,IN BASIS OF DESIGN(1)(2)(3)(4) <br /> RCDA-06 BULLSEYE DIFFUSER 100-160 14"0 PRICE RCDA,6"NECK <br /> SUPPLY 8 RETURN AIR DUCTS IN UNCONDITIONED SPACE MINERAL-WOOL BLANKET 6.0 <br /> RCDA-08 BULLSEYE DIFFUSER 175-300 18"0 PRICE RCDA,8"NECK <br /> SUPPLY B RETURN AIR DUCTS LOCATED OUTSIDE THE BUILDING MINERAL-WOOL BLANKET 8.0 RCDA-10 BULLSEYE DIFFUSER 250-450 22"0 PRICE RCDA,10"NECK <br /> SUPPLY 8 RETURN AIR DUCTS LOCATED IN BUILDING ENVELOPE ASSEMBLY MINERAL-WOOL BLANKET 16.0 RCDA-12 BULLSEYE DIFFUSER 350-550 27"0 PRICE RCDA,12"NECK <br /> SUPPLY WITH AIR TEMP<55°F OR>1057 WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 3.3 NOTES: (1) SUPPLY GRILLES SHALL BE DOUBLE DEFLECTION GRILLES <br /> SUPPLY WITH AIR TEMP<55°F OR>105°F WITHIN CONDITIONED SPACE DIRECTLY SERVED BY MINERAL-WOOL BLANKET 0.0 (2) PROVIDE 0 DEGREES DEFLECTION FOR CEILING MOUNTED GRILLES ONLY LON. <br /> DUCT (3) ALL DIFFUSERS,REGISTERS,AND GRILLES SHALL BE FACTORY PRIMED FOR CUSTOM PAINTING BY OTHERS.ALL TO BE PAINTED TO MATCH SURROUNDING WALL COLOR. <br /> SUPPLY DUCTS EXPOSED WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 0.0 (4) PROVIDE OPPOSED BLADE DAMPERS FOR BALANCING <br /> o <br /> RETURN 8 EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AN ENERGY RECOVERY `� a <br /> MEDIA AND UPSTREAM OF AUTOMATIC SHUTOFF DAMPER MINERAL-WOOL BLANKET 8.0 N z <br /> FAN SCHEDULE a o <br /> RELIEF&EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF MINERAL-WOOL BLANKET 16.0 <br /> DAMPER ELECTRICAL <br /> EQUIP N0. SERVICE MOUNTING/DISCHARGE AIRFLOW,CFM ESP.IN WG OPERATION WEIGHT,LBS BASIS OF DESIGN <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE,UPSTREAM OF AUTOMATIC SHUTOFF DAMPER AND VOLTAGE HP(W) N F <br /> GREATER THAN 2,800 CFM MINERAL-WOOL BLANKET 16.0 TF-1 I BREAK ROOM INLINE 1 250 1 0.25 120V I1P (150) WALL SWITCH 15 FANTECH FG BXL(1) o <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER MINERAL-WOOL BLANKET 8.0 <br /> AND GREATER THAN 2,800 CFM NOTES: (1) PROVIDE ECM MOTOR. <br /> L <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE AND LESS THAN 2,800 CFM MINERAL-WOOL BLANKET 7.0 <br /> OUTSIDE AIR DUCT IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS, MINERAL-WOOL BLANKET 0.0 DDOppp <br /> ISOLATED FROM CONDITIONED SPACE AT SIDES,TOP AND BOTTOM WITH R-11 INSULATION O J ACk <br /> O t„.�(FWASyNQQQ�p,,, <br /> NOTES: (1) DUCT INSULATION SHALL COMPLY WITH IMC AND WSEC. o <br /> (2) VAPOR RETARDER IS INSTALLED ON SUPPLY AND OUTSIDE AIR DUCT PER IMC 604.11. <br /> (3) EXTERNAL DUCT INSULATION IS IDENTIFIABLE PER IMC 604.7. <br /> (4) ALL DUCTWORK IS CONSTRUCTED AND SEALED PER IMC. �DODDi 5�2 <br /> (5) INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 PER IMC 604.3. <br /> r1 <br /> W = <br /> �w <br /> o warn <br /> V ,Lmx <br /> s o <br /> O�N <br /> Z <br /> t K W O <br /> W z>� <br /> IE Q3 w o <br /> FW K Q V <br /> W <br /> J W <br /> ZV <br /> W <br /> ~ N <br /> �� Y <br /> 0 O O—U <br /> Q ^Z Z Z <br /> J 2 O <br /> d U <br /> W <br /> Zz <br /> LL O : <br /> LL <br /> 0 (n Z <br /> J MIS � <br /> J } fY1 W <br /> Jaw O Z <br /> W <br /> g o <br /> N ,n <br /> �a Z <br /> o> W <br /> � <br /> WF <br /> W �WW <br /> W <br /> W <br /> H <br /> U <br /> W <br /> O <br /> K <br /> PROJECT#: <br /> 931-059 <br /> SHEET TITLE: <br /> SCHEDULES <br /> SHEET NO. <br /> M001 <br /> ity of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/26/2024 <br />
The URL can be used to link to this page
Your browser does not support the video tag.