Laserfiche WebLink
2021 WSEC-C DUCT INSULATION SCHEDULE GRILLE,REGISTER,&DIFFUSER SCHEDULE <br /> DUCT TYPE INSULATION TYPE MIN.R-VALUE CALLOUT DESCRIPTION AIRFLOW RANGE,CFM FACE SIZE,IN BASIS OF DESIGN(1)(2)(3)(4) <br /> RCDA-06 BULLSEYE DIFFUSER 100-160 14"0 PRICE RCDA,6"NECK <br /> SUPPLY 8 RETURN AIR DUCTS IN UNCONDITIONED SPACE MINERAL-WOOL BLANKET 6.0 <br /> RCDA-08 BULLSEYE DIFFUSER 175-300 18"0 PRICE RCDA,8"NECK <br /> SUPPLY B RETURN AIR DUCTS LOCATED OUTSIDE THE BUILDING MINERAL-WOOL BLANKET 8.0 RCDA-10 BULLSEYE DIFFUSER 250-450 22"0 PRICE RCDA,10"NECK <br /> SUPPLY 8 RETURN AIR DUCTS LOCATED IN BUILDING ENVELOPE ASSEMBLY MINERAL-WOOL BLANKET 16.0 RCDA-12 BULLSEYE DIFFUSER 350-550 27"0 PRICE RCDA,12"NECK <br /> SUPPLY WITH AIR TEMP<55°F OR>1057 WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 3.3 NOTES: (1) SUPPLY GRILLES SHALL BE DOUBLE DEFLECTION GRILLES <br /> SUPPLY WITH AIR TEMP<55°F OR>105°F WITHIN CONDITIONED SPACE DIRECTLY SERVED BY MINERAL-WOOL BLANKET 0.0 (2) PROVIDE 0 DEGREES DEFLECTION FOR CEILING MOUNTED GRILLES ONLY LON. <br /> DUCT (3) ALL DIFFUSERS,REGISTERS,AND GRILLES SHALL BE FACTORY PRIMED FOR CUSTOM PAINTING BY OTHERS.ALL TO BE PAINTED TO MATCH SURROUNDING WALL COLOR. <br /> SUPPLY DUCTS EXPOSED WITHIN CONDITIONED SPACE MINERAL-WOOL BLANKET 0.0 (4) PROVIDE OPPOSED BLADE DAMPERS FOR BALANCING <br /> o <br /> RETURN 8 EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AN ENERGY RECOVERY `� a <br /> MEDIA AND UPSTREAM OF AUTOMATIC SHUTOFF DAMPER MINERAL-WOOL BLANKET 8.0 N z <br /> FAN SCHEDULE a o <br /> RELIEF&EXHAUST WITHIN CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF MINERAL-WOOL BLANKET 16.0 <br /> DAMPER ELECTRICAL <br /> EQUIP N0. SERVICE MOUNTING/DISCHARGE AIRFLOW,CFM ESP.IN WG OPERATION WEIGHT,LBS BASIS OF DESIGN <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE,UPSTREAM OF AUTOMATIC SHUTOFF DAMPER AND VOLTAGE HP(W) N F <br /> GREATER THAN 2,800 CFM MINERAL-WOOL BLANKET 16.0 TF-1 I BREAK ROOM INLINE 1 250 1 0.25 120V I1P (150) WALL SWITCH 15 FANTECH FG BXL(1) o <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE,DOWNSTREAM OF AUTOMATIC SHUTOFF DAMPER MINERAL-WOOL BLANKET 8.0 <br /> AND GREATER THAN 2,800 CFM NOTES: (1) PROVIDE ECM MOTOR. <br /> L <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE AND LESS THAN 2,800 CFM MINERAL-WOOL BLANKET 7.0 <br /> OUTSIDE AIR DUCT IN UNHEATED EQUIPMENT ROOMS WITH COMBUSTION AIR LOUVERS, MINERAL-WOOL BLANKET 0.0 DDOppp <br /> ISOLATED FROM CONDITIONED SPACE AT SIDES,TOP AND BOTTOM WITH R-11 INSULATION O J ACk <br /> O t„.�(FWASyNQQQ�p,,, <br /> NOTES: (1) DUCT INSULATION SHALL COMPLY WITH IMC AND WSEC. o <br /> (2) VAPOR RETARDER IS INSTALLED ON SUPPLY AND OUTSIDE AIR DUCT PER IMC 604.11. <br /> (3) EXTERNAL DUCT INSULATION IS IDENTIFIABLE PER IMC 604.7. <br /> (4) ALL DUCTWORK IS CONSTRUCTED AND SEALED PER IMC. �DODDi 5�2 <br /> (5) INSULATION SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF 50 PER IMC 604.3. <br /> r1 <br /> W = <br /> �w <br /> o warn <br /> V ,Lmx <br /> s o <br /> O�N <br /> Z <br /> t K W O <br /> W z>� <br /> IE Q3 w o <br /> FW K Q V <br /> W <br /> J W <br /> ZV <br /> W <br /> ~ N <br /> �� Y <br /> 0 O O—U <br /> Q ^Z Z Z <br /> J 2 O <br /> d U <br /> W <br /> Zz <br /> LL O : <br /> LL <br /> 0 (n Z <br /> J MIS � <br /> J } fY1 W <br /> Jaw O Z <br /> W <br /> g o <br /> N ,n <br /> �a Z <br /> o> W <br /> � <br /> WF <br /> W �WW <br /> W <br /> W <br /> H <br /> U <br /> W <br /> O <br /> K <br /> PROJECT#: <br /> 931-059 <br /> SHEET TITLE: <br /> SCHEDULES <br /> SHEET NO. <br /> M001 <br /> ity of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/26/2024 <br />