Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING A STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-L 310.16, Chapter 9 Table 4, 5, &9. Locations specific BUS BAR RATING X 120%) - MAIN BREAKER RATING infinit solar <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p infinity <br /> solar <br /> AC OUTPUT 768 W temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA98661 <br /> PHONE:1-800-818-0598 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP 5°CINFINITY SOLAR.COM <br /> AMBIENT TEMP HIGH TEMP 2°/ ° THIS PANEL IS FED BY MULTIPLE SOURCES <br /> MODULE: (10) ZNSHINESOLAR ZXM7-SH108-410M NOM.MAX.POWER AT STC(PMAX) 410 WATT ( �) 26 C UTILITY AND SOLAR)) REVISIONS <br /> INVERTER: (05)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V CONDUIT HEIGHT 7/8" Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C AC OUTPUT CURRENT 16A Initial Design 4/23/24 00 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT CONDUCTOR TEMPERATURE RATE 901C NOMINAL AC VOLTAGE 240V <br /> WITHIN 10' OF UTILITY METER NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED NOTE: -TANDEM BREAKERS TO BE USED TO <br /> NOTE : WITHIN 3FT OF AC DISCONNECT. POINT OF INTERCONNECT, LOAD SIDE Signature with Seal <br /> ATTIC RUN -YES MAKE ROOM FOR PV CIRCUIT BREAKER EXISTING 240V/200A BUS BAR RATING, <br /> SHUTDOWN - NO MAIN SERVICE PANEL,SINGLE PHASE, <br /> WITH A 200A MAIN BREAKER <br /> UTILITY COMPANY-SNOHOMISH PUD <br /> UTILITY METER#69 123 669 <br /> EXISTING <br /> BI-DIRECTIONAL Project Name& <br /> (N)BLADE TYPE NON-FUSIBLE UTILITY METER, M Address <br /> (N) 125A COMBINER PANEL, AC DISCONNECT NEMA 3R 1-PHASE,3W, <br /> 240V,3W,1-PHASE 30A-2P 120/240VAC(VISIBLE, 120V/240V <br /> LOCKABLE, LABELED) Lu <br /> U <br /> 200A E--{ z <br /> w <br /> 0 0 <br /> N <br /> (E)LOADS CO rn Q Q <br /> r <br /> (10) ZNSHINESOLAR ZXM7-SH108-410M N PVBREAKER LU zT <br /> z Q <br /> (N)JUNCTION BOX ( ) 10:� c" w <br /> (05) AP SYSTEMS DS3-L INVERTERS 600V, NEMA4 20A/2P > CN w a- w <br /> UL LISTED 20A L1 tY w <br /> BRANCH 1 -10 MODULES WITH 05 MICRO INVERTERS �� LU <br /> L2 M <br /> Q <br /> L1 L1 <br /> L2 L2 r--C'--- ------ --- ---- --- — ------- <br /> W J ME] W JEW W W Wilm <br /> a a a a a a t a a s <br /> --- -- �---- ---- — c G <br /> PL � Sheet Name <br /> L J L J L J L J L J <br /> 3-LINE <br /> ^ --- <br /> ---------- ---------- --------- -------- -------� 3 DIAGRAM <br /> 1 2 3 EXISTING GROUNDING <br /> Sheet size <br /> ELECTRODE SYSTEM <br /> ANSI B <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE SIZE\TYPE\AMP. WIRE #C.C.C. CONDUIT TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE 1 1" X 17„ <br /> TAG# DEVICES RATING MULT CURR X 125% OCP DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(/o) <br /> Sheet Number <br /> 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 2 TRUNK <br /> AIR CABLE <br /> 1.00 x 1.00 x 40A 40.00A <br /> 16.00A #6 AWG 20 0.28 E 1 .1 <br /> O 05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 2 3/4" EMT 1.00 x 1.00 x 40A 40.00A 16.00A #8 AWG 35 0.48 0.93< <br /> 2 <br /> O05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \ 35A @75°C 20A 2 3/4" EMT 1.00 x 1.00 x 35A 35.00A 16.00A #8 AWG 10 0.17 <br />