My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
212 BRIDGEWAY 2025-03-24
>
Address Records
>
BRIDGEWAY
>
212
>
212 BRIDGEWAY 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2025 9:53:09 AM
Creation date
1/31/2025 11:31:37 AM
Metadata
Fields
Template:
Address Document
Street Name
BRIDGEWAY
Street Number
212
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MICROINVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERATURE SPECIFICATIONS <br /> MANUFACTURER/MODEL# ENPHASE IQ8PLUS-72-2-US(240V) MANUFACTURER/MODEL# SILFAB SIL 400HC+(400W) CONTRACTOR <br /> RECORD LOW TEMP -5°C <br /> INPUT POWER RANGE 235W-440W VMP 38.79 V AMBIENT TEMP(HIGH TEMP 2%AVG.) 26°C <br /> MIN/MAX START VOLTAGE 22V/58V IMP 10.32 A <br /> NOMINAL AC VOLTAGE 240V VOC 45.51 V MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" � <br /> MAX CONT.OUTPUT CURRENT 1.21A ISC 10.85 A <br /> MAX CONT.OUTPUT POWER 1290W ITEMP.COEFF.VOC o.zs//'C HIGH PERFORMANCE <br /> MAX MODULES PER STRING 113(13 MICROINVERTERS) HOMES <br /> HIGH PERFORMANCE HOMES <br /> 4200 SE COLUMBIA WAY, STE <br /> C, VANCOUVER, WA, 98661 <br /> PHONE- (971)506-5978 <br /> LIC. NO. - HIGHPPH876DN <br /> ROMEX CAN BE USED IN LIEU OF CONDUIT FOR INTERIOR BUILDING AND ATTIC <br /> RUNS ONLY. DO NOT USE ROMEX IN CONDUIT OR OUTDOOR ENVIRONMENTS. <br /> TO UTILITY GRID <br /> (N) ENPHASE COMBINER PANEL L1 L2 N METER#: 218713 <br /> NEMA 3R, UL LISTED,125A RATED <br /> SILFAB SIL 400HC+(400W) (ENPHASE X-IQ-AM1-240-4/4C) LINE E BI-DIRECTIONAL <br /> (N)AC DISCONNECT 30A UTILITY METER <br /> 10A OR 15A BREAKER IS VISIBLE, LOCKABLE, M <br /> 10 MICROINVERTERS IN STRING 1 IQ LABELED AND NON-FUSIBLE, 1-PHASE, 3-W, <br /> SUITABLE FOR USE <br /> CELL WIRELESS 240V, NEMA 3R, UL LISTED LOAD 120V/240V <br /> #12 AWG MODEM COMMS L1 L1 PROJECT NAME I ADDRESS <br /> ROBERT DRISKILL <br /> ENPHASE Q L2 L2 212 BRIDGE WAY, <br /> CABLE(S) N N (N) 200A/2P MAIN EVERETT, WA 98201 <br /> 15A/2P BREAKER, 240V <br /> ENPHASE IQ8PLUS-72-2-US(240V) (N) JUNCTION BOX 1 G �G �-�' APN#: 005-203-00-003-100 <br /> MICROINVERTERS ONE UNDER 600 V, NEMA 3R <br /> EACH PANEL (240V) UL LISTED Lll20A/2P 2 o (N)200A MAIN AHJ: COUNT(WA)Y OF SNOHOMISH <br /> L2 SERVICE PANEL, UTILITY: SNOHOMISH COUNTY <br /> ° 240V PUD <br /> ° SYSTEM DETAILS <br /> ° DC SIZE:4.000 KW DC-(STC) <br /> PV 20A/2P LOAD SIDE AC SIZE:2.900 KW AC <br /> N INTERCONNECTION (10)ENPHA SILFAB SIL400HUS-72- - <br /> LG (10)ENPHASE IQ8PLUS-72-2-US(240V) <br /> �_ _ � AT MAIN PANEL <br /> v G <br /> #6 AWG BARE Cu N REVISIONS <br /> G <br /> REV DESCRIPTION DATE <br /> GEC <br /> EXISTING GROUNDING <br /> INSTALL NEW MSP 200A/200A RATED ELECTRODE SYSTEM <br /> SHEET TITLE <br /> ELECTRICAL <br /> DESCRIPTION FORMULA RESULT DIAGRAM <br /> PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=(10 x 1.2])A x 1.25 15.13A(SELECTED PV BREAKER=20A) <br /> DRAWN DATE 5/16/2024 <br /> 120%RULE FOR BACKFEED BREAKER NEC 705.12 BUS BAR RATING x 1.2-MCB RATING=MAX ALLOWABLE PV BREAKER SELECTED PV BREAKER<=MAX ALLOWABLE PV BREAKER <br /> 200A x 1.2-200A=40A 20A<=40A DRAWN BY VV <br /> EXPECTED TEMP QTY OF CURRENT CONDUIT FILL MINIMUM WIRE GAUGE& CONDUCTOR CONDUCTOR REQUIRED CIRCUIT ADJUSTED CONDUCTOR NEUTRAL GROUND WIRE <br /> WIRE ID DERATE CARRYING CONDUIT SIZE AMPACITY @ AMPACITY @ CONDUCTOR AMPACITY CONDUCTOR SHEET NUMBER <br /> WIRE TEMP(°C) (90°C) CONDUCTORS DERATE (TBD ON SITE) TYPE 90°C(A) 75°C(A) (A) AMPACITY @ 90°C(A) SIZE&TYPE SIZE&TYPE <br /> 1 26 1 4 0.8 3/4"METAL #10 THWN-2 40 35 15.13 32.00 NONE #8 THWN-2 PV-04 <br /> 2 26 1 2 1 3/4"METAL #10 THWN-2 40 35 15.13 40.00 #10 THWN-2 #8 THWN-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.