ELECTRICAL SPECIFICATIONS 400 , <br /> Test Conditions STC NOCT <br /> Module Power(Pmax) Wp 400 298 <br /> • Maximum power voltage(Vpmax) V 38.79 36.05 <br /> • • Maximum power current(Ipmax) A 10.32 8.27 <br /> • • Open circuit voltage(Voc) V 45.51 42.69 <br /> SILFAB PRIME S I L FA B • Short circuit current(Isc) A 10.85 8.75 <br /> SOLAR® Module efficiency % 20.2% 18.8% <br /> Maximum system voltage(VDC) V 1 0 <br /> SIL-400 HC+ Series fuse rating A <br /> Power Tolerance Wp Ot +10 <br /> Measurement conditions:STC 1000 W/m'•AM 1.5•Temperature 25°C•NOCT 800 W/m2•AM 1.5•Measurement uncertainty s 3% <br /> Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by i5%and power by 0 to+10W. <br /> MECHANICAL PROPERTIES/COMPONENTS L METRIC <br /> Module weight 21.3kg 20.2kg 47lbs t0.41bs <br /> Dimensions(H x L x D) 1914 mm x 1036 mm x 35 mm 75.3 in x40.8 in x 1.37 in <br /> Maximum surface load(wind/snow)* 5400 Pa rear load/5400 Pa front load 112.8 lb/ft'rear load/112.8 Ib/ft'front load <br /> Hail impact resistance o 25 mm at 83 km/h a 1 in at 51.6 mph <br /> Cells 132 Half cells-Si mono PERC 132 Half cells-Si mono PERC <br /> 9 busbar-83 x 166 m m 9 busbar-3.26 x 6.53 in <br /> Glass 3.2 mm high transmittance,tempered, 0.126 in high transmittance,tempered, <br /> DSM antireflective coating DSM antireflective coating <br /> Cables and connectors(refer to installation manual) 1350 mm,a 5.7 mm,MC4 from Staubli 53 in,o 0.22 in(12AWG),MC4 from Staubli <br /> Backsheet High durability,superior hydrolysis and UV resistance,multi-layer dielectric film, <br /> fluorine-free PV backsheet <br /> Frame Anodized Aluminum(Black) <br /> Bypass diodes 3 diodes-30SQ045T(45V max DC blocking voltage,30A max forward rectified current) <br /> Junction Box UL 3730 Certified,IEC 62790 Certified,IP68 rated <br /> TEMPERATURE RATINGS 7= WARRANTIES I <br /> Temperature Coefficient Isc +0.064%/°C Module product workmanship warranty 25 years*` <br /> Temperature Coefficient Voc -0.28%/°C Linear power performance guarantee 30years <br /> Temperature Coefficient Pmax -0.36%/°C >_97.1%end lstyr <br /> NOCT(t 2°C) I 45°C >_91.6%end 12th yr <br /> >_85.1%end 25th yr <br /> Operating temperature I -40/+85°C >_82.6%end 30thyr <br /> CERTIFICATIONS HIPPING SPECS <br /> UL61215-1:2017 Ed.1,UL 61215-2:2017 Ed.1,UL 61730-1:2017 Ed.1,UL 61730-2:2017 Modules Per Pallet: 26 or26(California) <br /> Ed.1,CSA C22.2#61730-1:2019 Ed.2,CSA C22.2#61730-2:2019 Ed.2,IEC 61215-1:2016 <br /> Product Ed.1,IEC 61215-2:2016 Ed.1,IEC 61730-1:2016 Ed.2,IEC 61730-2:2016 Ed.2,IEC <br /> 61701:2020(Salt Mist Corrosion),IEC 62716:2013(Ammonia Corrosion),UL Fire Rating: Pallets Per Truck 32 or30(California) <br /> Type 2,CEC Listed. <br /> Factory IS09001:2015 Modules Per Truck 832 or 780(California) <br /> A Warning.Read the Safety and I nstallation Manual for mounting specifications and before handling,installing and operating modules. <br /> 12 year extendable to 25 years subject to registration and conditions outlined under"Warranty"at silfabsolaccom. <br /> PAN files generated from 3rd party performance data are available for download at:silfa bsotar.com/downloads. <br /> 75.3"[1914mm] <br /> v E <br /> 12.1"[307mm] 51.2[1300mm] 12.1"[307mm] <br /> RELIABLE E N E R G Y. Mounting Hole(x4) <br /> DIRECT FROM THE SOURCE . SILFAB SOLAR INC. <br /> 0.5" <br /> [12mm] 1770 Port Drive <br /> Designed to outperform. ,•°`"`°A�� Burlington WA98233 USA <br /> 2023 + o T+1360.569.4733 <br /> Dependable, durable high-performance _ g info@silfabsolaccom <br /> p �a`Iw''" E E E 51LFAB50LAR.COM <br /> solar panels engineered for North TE <br /> ""'"°"""""""""° ,.4" 35mm ® - <br /> o O7 0_ 7149 Logistics Lane <br /> au�.� N " Fort Mill SC29715USA <br /> American homeowners. f A moo <br /> d m o T+1839.400.4338 <br /> w o v <br /> S I L F A B S O L A R.C 0 M 3 E 240 Courtneypark Drive East <br /> 3700M6'M3 53.15" N c�- Mississauga ON L5T2S5 Canada <br /> - - -r [1350mm] a +1905.255.2501 <br /> n Cable Length i�. 2 F+1905.696.0267 <br /> rainage Hole(x8) Oj 61 Silfab-SIL-400-HC+-20240229 <br /> No reproduction of any kind is allowed without <br /> C ♦ [[� [�� I R o permission.swithou information is subject <br /> arto <br /> (`� L C modifications without notice.O silfab War Inc., <br /> 2.4"[60mm] 8"[200mm] 2022.Silfab Solar-is a registered trademark of <br /> Intern. Si1fab Solar Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.