Laserfiche WebLink
_ SolarEdge Home Wave Inverter <br /> SolarEdge Home Wave Inverter Z For North America <br /> For North America < SE380OH-US / SE5000H-US / SE6000H-US/ <br /> SE760OH-US / SE10000H-US / SE1140OH-US <br /> SE380OH-US / SE5000H-US / SE6000H-US / m Applicable to inverters with part <br /> SE760OH-US / SE10000H-US / SE1140OH-US number <br /> OUTPUT <br /> r7/12 2�� 3800 @ 240V 6000 @ 240V 11400 @ 240V <br /> Rated AC Power Output 5000 7600 0000 VA <br /> Y EAR 3300 @ 208V 5000 @ 208V 10000 @ 208V <br /> 9 Maximum AC Power Output 3800 @ 240V 5000 6000 @ 240V 7600 10000 11400 @ 240V VA <br /> WARRANTY ' 3300 @ 208V 5000 @ 208V 10000 @ 208V <br /> PO AC Output Voltage ✓ ✓ ✓ ✓ ✓ ✓ Vac <br /> O Min.-Nom.-Max.(211-240-264) <br /> Output Voltage ✓ ✓ ✓ <br /> Min.-Nom.-Max.(183-208-229) Vac <br /> Mi <br /> AC Frequency(Nominal) 59.3-60-60.511 Hz <br /> ® Maximum Continuous Output Current 16 21 2S 32 42 47.S A <br /> @240V <br /> O Maximum Continuous Output Current 16 24 48.5 A <br /> @208V <br /> Power Factor 1,Adjustable-0.85 to 0.85 <br /> GFDI Threshold 1 A <br /> solar VM„,m �a�. 'Z +I"la- Utility Monitoring,lslanding <br /> O ® O O Protection,Country Configurable Yes <br /> Thresholds <br /> - INPUT <br /> O O <br /> Maximum DC Power @240V 5900 7750 9300 11800 15500 17650 W <br /> O O Maximum DC Power @208V S100 7750 15500 W <br /> Transformer-less,Ungrounded Yes <br /> Maximum Input Voltage 480 Vdc <br /> O O O Nominal DC Input Voltage 380 Vdc <br /> _ Maximum Input Current @240Vt21 10.5 13.S 16.5 20 27 30.5 Adc <br /> Maximum Input Current @208Vt21 9 13.5 27 Adc <br /> Max.Input Short Circuit Current 45 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection 600k Sensitivity <br /> Optimized installation with HD-Wave technology Maximum Inverter Efficiency 99.2 <br /> CEC Weighted Efficiency gg 99 @ 240V <br /> 98.5 @ 208V <br /> / Specifically designed to work with power / UL1741 SA certified,for CPUC Rule 21 grid Nighttime Power Consumption <2.5 W <br /> optimizers compliance <br /> (1)For other regional settings please contact SolarEdge support. <br /> (2)A higher current source may be used;the inverter will limit its input current to the values stated. <br /> / Record-breaking 99%weighted efficiency / Small, lightweight,and easy to install both <br /> outdoors or indoors <br /> / Quick and easy inverter commissioning directly <br /> from a smartphone using SolarEdge SetApp / Built-in module-level monitoring <br /> / Fixed voltage inverter for longer strings / Optional:Faster installations with built-in <br /> consumption metering (1%accuracy)and <br /> / Integrated arc fault protection and rapid production revenue grade metering (0.5% <br /> shutdown for NEC 2014-2023 per articles accuracy,ANSI C12.20) <br /> 690.11 and 690.12 <br /> solaredge.com solar=ee <br />