Laserfiche WebLink
PHOTOVOLTAIC ROOF MOUNT SYSTEM <br /> 29 MODULES - SYSTEM SIZE STC (12.470 kW DC / 10.121 kW AC) <br /> 605 33RD ST, EVERETT, WA 98201 , USA (47.9741414, -122.2227278) AR SPAN <br /> C L C C T R I C <br /> SYSTEM SUMMARY STC(12.470 kW DC/ 10.121 MAC) 49' 11" SHEET INDEX <br /> `STC DC:(29)430W=12.470 kW —— — —— —— —— —— CONTRACTOR:ARTISAN ELECTRIC <br /> STC AC:(29)349W=10.121 kW PV-1 COVER PAGE ADDRESS:969SNEBRASKA STREET SUITE A <br /> • (29)SILFAB SOLAR INC.SIL-430 QD MODULES PV-2 ROOF PLAN WITH MODULES <br /> SEATTLE,WA 98108,USA <br /> • (29)ENPHASE ENERGY INC.IQ8A-72-2-US[240VI MICROINVERTERS I PV-2.1 STRINGING LAYOUT <br /> PHONE:12065491307 <br /> • 2x BRANCHES OF 10 CONNECTED N PARALLEL I PV-2.2 MODULE LAYOUT EMAIL:geoH.vestman@artlsanelectdanc.com <br /> • 1x BRANCH OF 9 CONNECTED IN PARALLEL I PV-3 ATTACHMENT DETAIL LICENSE#:ARTSE1878DN <br /> PV-4 SINGLE LINE DIAGRAM ELECTRICAL LICENSE#:ARTSEI936L1 <br /> GOVERNING CODES I REVISIONS <br /> • 2021 WASHINGTON STATE FIRE CODE PV-5 WIRING CALCULATION <br /> • 2021 WASHINGTON STATE BUILDING CODE I PV-6 PLACARDS <br /> I DESCRIPTION DATE REV <br /> • 2021 WASHINGTON STATE RESIDENTIAL CODE I PV-7+ EQUIPMENT SPECIFICATION <br /> • 2023 NFPA 70-NATIONAL ELECTRICAL CODE O <br /> GENERAL NOTES I � AHJ: EVERETT(CITY OF),WASHINGTON <br /> UTILITY:SNOHOMISH COUNTY PUD NO 1 <br /> 1) ALL PANELS,SWITCHES,ETC.SHALL HAVE SUFFICIENT GUTTER SPACE I <br /> AND LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO ACCOMMODATE <br /> CONDUCTORS SHOWN. I y <br /> 2) THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE I <br /> LOCAL JURISDICTION AND UTILITY IS OBTAINED. I ARRAY LOCATIONS <br /> 3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE I I SIGNATURE&SEAL <br /> THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE <br /> WEATHERPROOF AND SHALL BE LISTED BY'UL'FOR THE TYPE OF <br /> APPLICATION AND'UL'LABEL SHALL APPEAR ON ALL ELECTRICAL <br /> EQUIPMENT. <br /> 4) WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN <br /> CONCEALED SPACES(UNLESS APPROVED OTHERWISE)AND SCHEDULE-40 <br /> PVC FOR BELOW GROUND INSTALLATIONS UNLESS NOTED OTHERWISE. <br /> 5) AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF <br /> THE ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION. <br /> 6) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL <br /> GROUNDING ELECTRODE CONDUCTOR IF NECESSARY. � I I �t <br /> I <br /> I HOMEOWNER INFO <br /> I = <br /> I � � <br /> I Q � <br /> I N M <br /> I '^ 0) CDnV J Q N <br /> I..[. E <br /> I + p <br /> I JBA <br /> HOUSE PHOTO z <br /> SCALE: NTS W O U) <br /> I I 29 \�\ < a <br /> / - <br /> DELTA J5UNCTION 0 2 <br /> 13'-3" i N W o . <br /> CBA N. NORTHWEST <br /> F I J <br /> O] DELTA U) O <br /> I i O w I DA <br /> I <br /> a <br /> BAY SIDE <br /> U M co o <br /> I Everett 0- <br /> O <br /> I CDQ <br /> ti I MSP <br /> 0 NEW PV MODULE FENCE oRT GARDN ER 3 <br /> F rest Park <br /> Z I © © p <br /> ® FRONT OF HOUSE GATE Q I e SHEET NAME <br /> LLB J Lowell Park <br /> I I DIMENSIONS DRIVEWAY O�i I HARBORVIEW-SEAHU VIEW REDGEGEACIER VIEW <br /> W I BOULEVARD MA,ISON COVER PAGE <br /> J — OBSTRUCTION \ I BLUFFS oe'reLL <br /> -------------- PROPERTY LINE N E <br /> 0' 1" ROJECT SITE SIZE <br /> AC JUNCTION BOX MAIN SERVICE PANEL <br /> JBA MSP -- �O' gl2 Map data©2024Gooc <br /> (NEW) (EXISTING,200A) ANSI B <br /> CBA (NEW) 90 <br /> BINER 5/SC �JMUTILITYTER 15' 7" VICINITY MAP SHEET NUMBER <br /> LAC DISCONNECT FUSED SITE PLAN SCALE: NTS� PV-1 <br /> (NEW) SCALE: 1/16" = V-0" VERNON AV E N U E <br />