BACKFEED BREAKER SIZING <br /> MAX. CONTINUOUS OUTPUT 32.00A @ 240V <br /> 32.00 1XI 1.25 1 = 140.00AMPS 140A BREAKER-OK <br /> SEE 705.12 OF 2020 NEC <br /> 200 Xj 1.20 1 = 1240 <br /> 240 - 0 1 = 240A ALLOWABLE BACKFEED <br /> CLIENT: <br /> EMILY GIRAUD <br /> 1916 ROCKEFELLER AVE,EVERETT,WA <br /> 98201 <br /> AHJ:CITY OF EVERETT <br /> UTILITY:SNOHOMISH PUD <br /> (E)UTILITY METER METER:10 534 791 <br /> APN:004370-380-025-00 <br /> (E)200A RATED EMAIL:MLENSQ@YAHOO.COM <br /> MAIN SERVICE PANEL <br /> (SPLIT-HOT BUS) FINANCE: MOSAIC <br /> 1 PH,120/240V 60HZ <br /> STRING-1 STRING-2 <br /> 8 SILFAB SOLAR:SIL-430QD 9 SILFAB SOLAR:SIL-430QD SYSTEM: <br /> TO OTHER SYSTEM SIZE(DC):17 X 430=7.310 kW <br /> LOADS SYSTEM SIZE(AC):7.600 kW @ 240V <br /> IN)40A/2P PV BREAKER MODULES:17 X SILFAB SOLAR:SIL-430QD <br /> IN)SOLAREDGE (N)60A RATED o o OPTIMIZERS:17 X SOLAREDGE S440 <br /> BE [Sill AC DISCONNECT INVERTER:SOLAREDGE SE760OH-USRGM <br /> 4-#10 AWG,THWN-2 INVERTER EATON DG222URB(OR [SI1] <br /> 1-#10 EGC,THWN-2 EQUIVALENT) (E)60A <br /> IN 3/4"OR AC KNIFEBLADE,LOCKABLE, <br /> r - ---- --- LARGER EMTCONDUIT <br /> DC NEMA 3R,UL LISTED <br /> //EE�� <br /> I "-. <br /> TO UTILITY <br /> JUNCTION VERHEAD-DROP THROUGH <br /> BOX ________ ROOF <br /> ________ ____ __________ FEED <br /> RAPIDSOLAREDGE S440 SOLAREDGE 5440 SHUTDOWN <br /> POWER OPTIMIZERS POWER OPTIMIZERS SWITCH <br /> 4-#10 AWG,PV WIRE <br /> 1-#6AWGINFREEAIROR , N-2 1 3-#8 AWG,THWN-2 <br /> #10 AWG MUST BE IN EMT CONDUIT 1-#10 EGC,THWN-2 1-#10 EGC,THWN-2 <br /> IN 3/4"OR LARGER EMT IN 3/4"OR LARGER EMT REVISIONS <br /> CONDUIT CONDUIT NO. REVISED BY DATE <br /> freedom- <br /> FOREVER <br /> FREEDOM FOREVER LLC <br /> 43445 BUSINESS PARK DR#110,TEMECULA, <br /> CA 92590 <br /> Tel:(800)385-1075 <br /> GREG ALBRIGHT <br /> �� g�N— <br /> CONTRACTOR LICENSE: <br /> ELECTRICAL ADMINISTRATOR ALBRIG*807C1 <br /> NOTE: <br /> CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED <br /> ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT THREE LINE DIAGRAM <br /> TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS JOB NO: DATE: DESIGNED BY: SHEET: <br /> 489390 8/28/2024 E.T. PV-4 <br />