My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1916 ROCKEFELLER AVE 2025-03-24
>
Address Records
>
ROCKEFELLER AVE
>
1916
>
1916 ROCKEFELLER AVE 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2025 1:23:13 PM
Creation date
1/31/2025 1:20:42 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
1916
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CSA CSA <br /> GROUP"' GROUP"' <br /> Certificate: 70131735 Master Contract: 266909 Certificate: 70131735 Master Contract: 266909 <br /> Project: 80182385 Date Issued: 2023-11-29 Project: 80182385 Date Issued: 2023-11-29 <br /> Downward Design Load(lb/ft2) 33.9 Down-Slope Load (lb/ft') 16.8 <br /> Upward Design Load(lb/ft2) 33.9 <br /> Down-Slope Load(lb/ft2) 16.5 UL 2703 and TIL Mechanical Load ratings tested module area 27.76 sq ft: <br /> NXT Systems without DTD Butyl Attachment <br /> Model NXT - Flush-to-Roof is an extruded aluminum rail PV racking system that is P30817211, Rail Splice P30808218, or Rail <br /> UMOUNT installed parallel to the roof in landscape or portrait orientations. Clamp P30817214 <br /> Downward Design Load(lb/ft2) 50.1 <br /> Upward Design Load (lb/ft2) 22.2 <br /> NXT UMOUNT Down-Slope Load (lb/ft2) 8.0 <br /> The system listed is designed to provide bonding/grounding,and mechanical stability for photovoltaic modules. <br /> The system is secured to the roof with the L-Foot components through the roofing material to building structure. NXT Systems with DTD Butyl Attachment <br /> Modules are secured to the racking system with aluminum mid clamps and aluminum end clamps. The modules P30817211, Rail Splice P30808218, or Rail <br /> are bonded to the racking system with bonding mid and end clamps with piercing points.Fire ratings of Class A Clamp P30817214 <br /> with Type 1,2,3 (with metallic frame), 10(with metallic frame), 19,22,25,29,or 30 for steep and low slope. Downward Design Load(lb/ft2) 39.47 <br /> Tested at 5"interstitial gap which allows installation at any stand-off height. Upward Design Load (lb/ft2) 22.2 <br /> The grounding of the system is intended to comply with the latest edition of the National Electrical Code,to Down-Slope Load (lb/ft2) 8.0 <br /> include NEC 250&690. Local codes compliance is required,in addition to national codes.All <br /> grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used UL 2703 and TIL Mechanical Load ratings tested module area 29.49 sq ft: <br /> during the certification testing for the current edition of the project report. <br /> NXT Systems with all components included in <br /> Latest Install Manual revision: PUB2023NOV 10 PUB2023NOV 10 Install Manual <br /> UL 2703 Mechanical Load ratings for tested module area 21.86 sq ft: Downward Design Load(lb/ft2) 37.06 <br /> Upward Design Load(lb/ft2) 20.97 <br /> NXT Systems without DTD Butyl Attachment Down-Slope Load(lb/ft2) 7.53 <br /> P30817211, Rail Splice P30808218, or Rail <br /> Clamp P30817214 <br /> Downward Design Load (lb/ft2) 113.7 Model SM Ascender - One or two row elevated or non-elevated roof system is an extruded <br /> E <br /> ard Design Load (lb/ft2) 511 aluminum rail PV racking system that is installed to the roof in <br /> ortrait orientation. <br /> n-Slope Load (lb/ft2) 16.8 <br /> NXT Systems with DTD Butyl Attachment SM Ascender <br /> P30817211, Rail P Splice 30808218, or Rail <br /> Clamp lice 214 The system listed is designed to provide bonding/grounding,and mechanical stability for photovoltaic modules. <br /> The system is secured to the roof with the L-Foot components through the roofing material to building structure. <br /> Downward Design Load(lb/ft2) 51.1 Modules are secured to the racking system with aluminum mid clamps and aluminum end clamps.Fire rating of <br /> Upward Design Load (lb/ft2) 51.1 Class A when installed over non-combustible roofing materials. <br /> LQD 07 Rev.2019-04-30 ©2018 CSA Grow. All rights reserved. Pa e 6 DOD 507 Rev.2019-04-30 ©2018 CSA Grow. All ri hts reserved. Pau 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.