CONTRACTOR AHJ STAMP <br /> PURELIGHT POWER NEWCO LLC NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM <br /> 3521 AVION DRIVE SUITE#200, 6.970 KW DC/6.055 KW AC <br /> MEDFORD, OR 97504 Purelight 11103 3RD PLACE SOUTHEAST, EVERETT, WA 98208 <br /> PHONE-(541)816-4047 <br /> LIC. NO. -226333 <br /> DESIGN CRITERIA NEW PV SYSTEM SPECIFICATIONS APPLICABLE CODES <br /> 1. ROOF PITCH: 18°, 18' SYSTEM SIZE: DC SIZE:6.970 KW DC-(STC) ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: SHEET INDEX <br /> 2.AZIMUTH: 229°, 139' AC SIZE:6.055 KW AC 2021 WASHINGTON STATE BUILDING CODE PV-00 COVER PAGE <br /> 3.MODULE: (17)YUKON SERIES SEG-410-BMD-HV PROJECT NOTES 2021 WASHINGTON STATE RESIDENTIAL CODE <br /> 4. INVERTER: (03)HOYMILES HM-150ONT 1.1.1 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE 2021 WASHINGTON STATE FIRE CODE PV-01 SITE PLAN <br /> (02)HOYMILES HM-70ONT RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE(NEC),ALL 2020 NATIONAL ELECTRICAL CODE PV-02 ENLARGED VIEW <br /> (01)HOYMILES HM-350NT MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS,AND THE AS ADOPTED BY CITY OF EVERETT PV-03 ATTACHMENT PLAN&DETAILS <br /> 5.NOMINAL AMPERAGE: 25.22 AMPS RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING PV-03.1 FRAMING DETAIL STRUCTURAL STAMP <br /> 6. ROOF AREA: 2405 FT JURISDICTION'S(AHJ)APPLICABLE CODES. PV-04 ELECTRICAL DIAGRAM <br /> 7.PV ARRAY AREA: 357.39 FT 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED PV-05 I WARNING LABELS <br /> 8. PV ARRAY WEIGHT: 805.80 LBS AND THE PV SYSTEM MUST BE INSPECTED PRIOR TO OPERATION <br /> 9. ROOF SURFACE TYPE: COMPOSITE SHINGLE 1.1.3 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY-INTERACTIVE PV-05.1 DIRECTORY PLACARD <br /> 10. ROOF STRUCTURE: 2"X4"TRUSS @ 24"OC INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND SCOPE OF WORK PV-06 EQUIPMENT SPECIFICATIONS <br /> 11.BUILDING STORY: ONE STORY LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND 1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EQUIPMENT DATASHEETS ATTACHED <br /> 12.SNOW LOAD: 25 PSF OTHER GOVERNING CODES SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM. <br /> 13.WIND SPEED: 97 MPH 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF VICINITY MAP <br /> 14.WIND EXPOSURE: B CODE. IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL EXISTING ONSITE CONDITIONS TO DESIGN,SPECIFY,AND <br /> 15. RISK CATEGORY: II PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC INSTALL THE ROOF-MOUNTED PHOTOVOLTAIC SYSTEM <br /> AND AHJ. DETAILED IN THIS DOCUMENT <br /> GENERAL NOTES � <br /> SITE NOTES STRUCTURAL NOTES(CONT.) DISCONNECTION AND OVERCURRENT PROTECTION NOTESKS <br /> a <br /> 2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED 2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT TWIN`ft" <br /> ACCORDANCE WITH OSHA REGULATIONS. AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING <br /> 2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE CONTRACTOR. ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED"LINE <br /> AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER SIDE"(TYPICALLY THE UPPER TERMINALS). <br /> STORAGE BATTERIES. THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER 2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY <br /> 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY OR PROFESSIONAL ENGINEERING GUIDANCE. PERSONNEL, BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH PROJECT NAME <br /> PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. 2.3.5 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE <br /> 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND STAGGERED AMONGST THE ROOF FRAMING MEMBERS. BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO DAVE FERGUSON <br /> EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ® (425)737-6853 <br /> PROVIDED IN ACCORDANCE WITH SECTION NEC 110.26. WIRING&CONDUIT NOTES ACCORDANCE WITH 690.12 DF5557@GMAIL.COM <br /> 2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED,AND 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC <br /> MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM 690.8,690.9,AND 240. SATELLITE MAP 11103 3RD PLACE SOUTHEAST, <br /> APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO A EVERETT,WA 98208 <br /> ROOF COVERING SERVES TO PROTECT THE BUILDING OR 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S)IN APN#: 00574600000900 <br /> AHJ:CITY 74 EVERETT <br /> STRUCTURE. 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC ACCORDANCE WITH NEC 110.3(B). "" <br /> 2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN 2.6.6 IF REQUIRED BY THE AHJ,SYSTEM WILL INCLUDE ARC-FAULT = � . <br /> "`` <br /> EQUIPMENT LOCATIONS ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR CIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690.11 AND UTILITY: SNOHOMISH COUNTY PUD_ <br /> 2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS IN LABELING PER NEC UL1699B. <br /> ACCORDANCE WITH NEC 110.26. REVISIONS <br /> 2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE GROUNDING NOTES INTERCONNECTION NOTES REV DESCRIPTION DATE <br /> RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN ACCORDANCE r <br /> BY NEC 690.31 (A),(C)AND NEC TABLES 310.15(B)(2)(A)AND 310.15 PURPOSE,AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL WITH NEC 705.12. <br /> (B)(3)(C). BE RATED FOR SUCH USE. 2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS <br /> 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC OUTPUT MAY NOT EXCEED 120 PERCENT OF BUSBAR RATING PER <br /> PV MODULES IN ACCORDANCE WITH NEC 690.34. 690.43 AND NEC TABLE 250.122. NEC 705.12. - <br /> 2.2.4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED 2.5.3 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT <br /> WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE WITH NEC CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE <br /> SERVICING DISCONNECT.2.2.5 ALL EQUIPMENT SHALL BE 250.134 AND 250.136(A). PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF <br /> INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL IN 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED IN THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED <br /> ACCORDANCE WITH NEC APPLICABLE CODES. ACCORDANCE WITH NEC 690.45 AND INVERTER MANUFACTURER'S BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM 41� �� C� �J SHEET TITLE <br /> 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND INSTALLATION PRACTICES THE UTILITY SOURCE OCPD IN ACCORDANCE WITH NEC 705.12. <br /> RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN MANUFACTURER 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER y d COVER PAGE <br /> DOCUMENTATION AND APPROVED BY THE AHJ. 2.5.6 THE GROUNDING PANEL,TOTAL RATING OF ALL OVERCURRENT PROTECTION DEVICES <br /> STRUCTURAL NOTES CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE SHALL NOT EXCEED AMPACITY OF BUSBAR.HOWEVER,THE MAIN <br /> 2.3.1 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED IN REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING OVERCURRENT PROTECTION DEVICE MAY BE EXCLUDED IN �O + 22002983 w� <br /> ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION CONDUCTOR TO ANOTHER MODULE. ACCORDANCE WITH NEC 705.12. 41CISTEv- DRAWN DATE 9/10/2024 <br /> MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN 2.5.7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE 2.7.5 FEEDER TAP INTERCONNECTION(LOAD SIDE)IN ACCORDANCE ��� <br /> MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE COLORED GREEN OR MARKED GREEN IF#4 AWG OR LARGER PER NEC WITH NEC 705.12. �SSI ONAL DRAWN BY TSD <br /> BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, IN 250.119 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE WITH <br /> ACCORDANCE WITH RAIL MANUFACTURER'S INSTALLATION 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 TO NEC 705.11 WITH SERVICE ENTRANCE CONDUCTORS IN Wyssling Consulting,PLLC SHEET NUMBER <br /> PRACTICES. AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, ACCORDANCE WITH NEC 230.42. 76 N.Meadowbrook Drive,Alpine,UT <br /> 2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S OR INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED IN 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES Washington UBI#604981384 p\/_oo <br /> SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE ACCORDANCE WITH NEC 250,NEC 690.47 AND THE AHJ. OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING PER NEC 705.12. 1 V <br /> FLASHED&SEALED PER LOCAL REQUIREMENTS. 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(13)(1) Signed 9/11/2024 <br /> AND 2 TO REDUCE FIRE HAZARDS <br />