My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4600 BAKER DR 2025-07-17
>
Address Records
>
BAKER DR
>
4600
>
4600 BAKER DR 2025-07-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2025 7:39:59 AM
Creation date
2/3/2025 10:59:34 AM
Metadata
Fields
Template:
Address Document
Street Name
BAKER DR
Street Number
4600
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Jones Residence Neil Jorgensen <br /> 4600 BAKER DR 13 Architects LLC <br /> EVERETT,WA 98203 425-242-0369 <br /> Heating System Type: O All Other Systems Q Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Design Temperature Difference(AT) 49 <br /> Everett Paine AFBAT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Conditioned Floor Area(sq ft) 214 <br /> Average Ceiling Height Conditioned Volume <br /> 's Average Ceiling Height(ft) 7.0 1,498 <br /> Glazing and Doors U-Factor X Area = UA <br /> •�.Gons <br /> 0.30 53 15.99 <br /> Skylights U-Factor X Area = UA <br /> 0.50 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions No selection <br /> Select R-Value � <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> R-38 Vented ,J 0.027 214 5.78 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> R-21 Intermediate 1r 0.056 432 24.19 <br /> Floors U-Factor X Area UA <br /> R-3 0 0.029 100 2.90 <br /> i <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> I.Select R-value No selection --- <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Select conditioning No selection --- <br /> Slab on Grade(see Figure d) F-Factor X Length UA <br /> Instructions No selection <br /> Select R-Value a --- <br /> Location of Ducts •� <br /> Duct Leakage Coefficient <br /> ill Conditioned Space <br /> 1.00 <br /> Sum of UA 48.86 <br /> Envelope Heat Load 2,394 Btu I Hour <br /> Figure 1. Sum of UA X AT <br /> _ Air Leakage Heat Load 793 Btu/Hour <br /> VolumeX 0.6 X AT X.018 <br /> Above Grade Building Design Heat Load 3,187 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 3,187 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 4,462 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> S/ (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.