My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9502 18TH AVE W 2023 UNIT Q Plans 2025-07-15
>
Address Records
>
18TH AVE W
>
9502
>
UNIT Q
>
Plans
>
9502 18TH AVE W 2023 UNIT Q Plans 2025-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2025 8:32:43 AM
Creation date
2/3/2025 2:26:40 PM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9502
Tenant Name
UNIT Q
Permit
B2310-030
Year
2023
Notes
NEW SFR - REFRB2306-005 - UNIT Q
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SLIDING GLASS DOOR <br />SELF ADHESIVE -`F4' <br />- PER PLAN <br />MEMBRANE PAN I <br />SLIDING GLASS DOOR <br />FLASHING <br />NAIL FLANGE <br />NAIL ON FLEXIBLE <br />GALV Z FLASHING <br />FLASHING <br />2' MIN FROM TOP OF <br />FLOOR JOIST <br />LEDGER TO LAG SCREW <br />PER PLAN <br />5/4x4 CEDAR DECKING <br />_ <br />-----I a <br />PER PLAN <br />2x PT JOIST PER PLAN <br />P <br />II II II I HANGER PER PLAN <br />RIM JOIST — PT LEDGER PER PLAN <br />BUILDING PAPER SHEATHING PER PLAN <br />INSTALLED BEHIND <br />LEDGER AND PAN SIDING PER PLAN <br />FLASHING LAP �Fnl <br />R INSTALLED BEFORE SIDING <br />OVER HOUSE WRAP ,L. - <br />w/ BUILDING PAPER BEHIND IT w/ 8" <br />EXPOSED ON ALL 4 SIDES <br />DECK LEDGER DETAIL <br />rvcc N.T.S. <br />TO HOSE <br />ELECTRICAL <br />I METER MAIN <br />i----,ROD <br />PRONTO BEND <br />FRONT -INSTALLED ON <br />CORNEREXT. OF HOUSE <br />OF HOUSE <br />AT GARAGE _HOSE <br />515B <br />NSTALL <br />GROUNDING <br />12' FROM _. <br />PRONTO BEND <br />FOPTIFLA514 o/ FLASHING 9" MOISTOP <br />AND MOISTOP. TURN -� <br />FORTIFLA51H I' ONTO PANEL, <br />ALL SIDES 4 CORNERS. <br />2A2 TRIM @ PERIMETER FLASHING <br />TYP. <br />OPENING FOR ELEC. 60 MIN. BLDG <br />METER BOX, FIREPLACE tl PAPER 3EHIND <br />DIRECT VENT, RANGE VENT, METER PLAIN <br />DRYER VENT, ETC. <br />+ SEE DETAIL NO FOR MOISTOP INSTALL INSTRUCTIONS <br />ELECTRIC METER t HOSE BIB <br />LOCATION (NO GAS METER) <br />N J SCALE: N.T.5. <br />8'-0 TO L.L. <br />CF PRONTO BEND <br />j 314' 3'-0' <br />EWE TO EWE TO <br />EDGE EWE ELECTRICAL <br />METER MAIN <br />FRONT -- ® PRONTO BEND <br />CORNER NE-ALLED ON <br />OF HOUSE Eff OF HOUSE <br />AT GARAGE HOSE <br />GAS <br />-. METER IN6186STALL <br />GROUNDING <br />ROD 12' FROM_ <br />PRONTO BEND <br />FORTIFLAS14 o/ FLASHING <br />AND MOISTOP. TURN -- 9" Mv':SOP <br />FORTIFLAS14 I" ONTO PANEL, <br />ALL SIDES I, CORNERS. <br />FLASHING <br />2,2 TRIM @ PERIMETER TYp <br />OPENING FOR ELEC. 60 MIN. BLDG <br />METER BOX, FIREPLACE PAPER BEHIND <br />DIRECT VENT, RANGE VENT, METER MAIN <br />DRYER VENT, ETC. <br />. SEE DETAIL WIO FOR MOISTOP INSTALL INSTRUCTIONS <br />ELECTRIC It GAS METER, HOSE <br />BIB CLEARANCES $ LOCATIONS <br />N5 SCALE: N.T.S. <br />STUD- - <br />WATER-RESI5TIVE-\-'- <br />BARRIER <br />JOINT FLASHING- _ <br />INSTALL PLANKS <br />IN MODERATE _ <br />CONTACT _ _.-_ <br />SIDING PER <br />PLAN - <br />/ SIDING BUTT �CIrN FLASHING <br />W16 SCALE: W.T S. <br />309 FELT PAPER ' <br />STARTER STRIP <br />FLASHING <br />GUTTER PER _ <br />PLAN—- ROOF TRUSS <br />FASCIA PER PLAN-� <br />FLASHING DETAIL 'j EAVE <br />YVIJ SCALE, N.T.S. <br />t <br />-- 6'_D.-,. r I'ER TYP. <br />SIDING rl R PLAN <br />�._. -n^_ PR.Ii II D TRIM <br />Er I <br />�SIDING / INSIDE CORNER <br />YV I SCALE: N.T.S. <br />LAG SCREW <br />FG51F -.. ATTACHED <br />TO WTI ;- STUDS. LAG <br />LCRFW PENETRATE <br />STUD` I IN,, TYP, @ <br />li3 LIM, 2/3 HT OF <br />P;N - I I:'CH w/ 1 W <br />x :v . - STRAP MIN <br />OF HWT- <br />I,'3 :! OF HWT <br />EXTEND MIN. 6' UP JAMB <br />NERVASTRAL TO EXTEND <br />2' PAST THE INTERIOR <br />OF THE DOOR <br />/ST PIECE <br />EXTEND 12' BEYOND <br />OPENING <br />EXTERIOR DOOR FLASHING <br />Vtl J SCALE: N.T.5. <br />aarBe Tan 1 I.woeaG a <br />rmrt oroR i mrxeae <br />sloe a suoa <br />EQ. EQ. <br />SGD PER RAN <br />OPERABLE FIXED <br />PANEL , PANEL <br />LINE OF <br />NFRVESTRAL ---------- I --------- 26 HEARTWOOD CEDAR TRm, <br />BE311ND I I H,1. ALL SIDES, CAULK/SEAL <br />BDtran of EQ. - EQ. <br />SIDING j 343' LANDING TYP. <br />POUR AGAINST <br />NERVASTRAL <br />FRONT POROH PATYJ <br />I 3'-b' LANDING TYP. .,,,. ,.- <br />ODOR 216 HEARTWOOD CEDAR TRIM <br />THRESNDL� LANDING PER PLAN. POUR <br />AG,uNST NERVPsrRu sw uEARrwcOD CEDAR <br />TRIM W FLASNING 0 <br />NERVESTRAL ------------ <br />f NOOSE INTERSECTION, <br />-LANDING PERPLAN <br />- WHERE OCCURS <br />(MN. 313', TYP:) a (IFSTEPS TBD BY i LINE Of NERVESTRAL <br />Mp SILL SITE CONDITIONS ' - _ -- <br />CONC. WALL SLAB ON GRADE <br />s¢ aw Fa rear axn <br />_... _ - '. xn FImxr caul CETAL <br />EXT. LANDING DETAIL @ <br />�1 SLIDING GLASS DOOR, TYP <br />Vtl G STALE: N.T.S. <br />LEADER <br />\ / <br />ROUGH I <br />OPENING <br />l I JAMB \ <br />I / SILL <br />PENETRATION <br />I 6®6® <br />SILL '4 <br />i FLASHING j <br />BUILDING PAPER TO EXTEND <br />_ -- <br />MIN. 12' BEYOND ALL EDGES <br />STEP I <br />OF THE PENETRATION <br />. ATTACH SILL STRIP OF 9' WIDE MOISTOP (OR EQ.) FLASHING MATERIAL <br />WITH THE TOP EDGE EVEN WITH THE TOP OF THE ROUGH SILL. <br />•EXTEND THI5 STRIP AT LEAST 12' BEYOND THE EDGE OF THE ROUGH <br />OPENING <br />PENETRATION PROTECTION •ATTACH FLASHING MATERIAL WITH CORROSION -RESISTANT STAPLES. <br />NIA} SCALE: N.T.S. <br />+NOTE: SEAL ALL <br />(EXPOSED FASTENERSI <br />LAPPROVED <br />HING PER PLAN <br />INSULATIONPAPER <br />PER PLAN FLASHING <br />I0' ROLL) <br />PER PLAN I-I/2' GAP <br />ROOF AND 51DING <br />GLES <br />� F LT TO EXTEND UP <br />WALL 12' MIN, <br />ROOF SHEATHING PER PLAN <br />ROOF TRUSS <br />EROOF TO HALL FLASHING <br />Nll SCALE: N.T.S. <br />SEALANT —\ <br />WINDOW FRAME <br />\\ <br />3/8' BEAD CAULK <br />SILL ASSEMBLY <br />PER SPEC <br />SEALANT <br />TRIM PER ELEVATION <br />(WHERE APPLICABLE) <br />GYP. BD. <br />MOISTOP (SEE DETAIL <br />WIO FOR INSTALL) <br />EXT WALL PER <br />FORTIFLASH ON ALL <br />PLAN - <br />SIDES OF WINDOW <br />SIDING PER PLAN <br />INSULATION <br />(WHERE OCCURS) <br />BLDG. PAPER <br />_. <br />7/I6' PLYWD. SHEATHING <br />WINDOW SILL @ WOOD FRAME NALL <br />YVU ALE, N.T.S. <br />USE 3 STRAPS ON 75 GALLON AND GREATER SIZES <br />CATER HEATER (HOOT) STRAPS <br />iCALE: N.T.S. <br />CANT, BEAD C <br />STEP 2 <br />• ATTACH AMB STRIPS OF 9" WIDE M015TOP (OR EQ.). <br />FLASHING MATERIAL WITH INSIDE EDGE EVEN WITH THE JAMB <br />OF THE ROUGH OPENING. <br />• START JAMB STRIPS 2' BELOW SILL STRIP AND EXTEND 6' <br />ABOVE LOWER EDGE OF HEADER. <br />(-HEAD SEALANT <br />FLASHING UNDER NAIL FIN <br />2 2' <br />CUT AWAY <br />WINDOW EXCESS <br />WINDOW <br />FRAME OR BLDG. PAPER <br />FRAME OR <br />SIMILAR @ OPENING <br />SIMILAR <br />OPENING <br />OPENING <br />BUILDING <br />BUILDING PAPER <br />PAPER <br />TYP. <br />LINE OP BUILDING PAPER TYP. <br />NAIL FLANGE UNDER SILL STRIP <br />STEP 3 <br />STEP 4 <br />• APPLY A 3/8' CONTINUOUS BEAD OF CAULK TO THE BACK OF THE FRAME <br />• APPLY THE NEXT COURSE OF BUILDING PAPER (BUTTING TO THE <br />NAILING FLANGE AT ALL 51DES OF THE WINDOW <br />FRAME OPENING) OVER THE JAMB FLASHING MATERIAL. <br />• PLACE AND SECURE FRAME INTO ROUGH OPENING WITH FLANGES OVER THE <br />• APPLY SUCCEEDING LAYERS OF BUILDING PAPER IN SHINGLE <br />INSTALLED JAMB AND SILL f JAMB MOISTOP (OR EQ.) FLASHING MATERIAL. <br />BOARD FASHION UP THE WALL, LAPPING COURSES A MINIMUM OF <br />• NAIL WINDOWS PER WINDOW MANUFACTURER'S SPECIFICATIONS <br />1/2 PAPER WIDTH. <br />•STARTING FROM THE BASE OF THE WALL, APPLY BUILDING PAPER UNDER <br />THE SILL STRIP AND CUT ANY EXCESS BUILDING PAPER THAT MAY EXTEND <br />ABOVE THE SILL AND BETWEEN THE JAMBS OF THE OPENING <br />• ADD FORTIFLASH STICK FLASHING @ BOTH SIDES OF WINDOW <br />• APPLY SLOPED 28 GA.. 2 BACK PREFINI544ED METAL FLASHING TO OPENING. <br />• APPLY 6' FORTIFLASH OVER TOP HEAD FLANGE OF WINDOW. EXTEND PAST <br />JAMB FLASHING 2". <br />, STANDARD FLASHING MATERIAL APPLICATION AT OPENINGS <br />vL <br />SCALE: N.T.S. <br />GYP. BD. <br />INSULATION <br />74 <br />(WHERE OCCURS) <br />TRIMMER <br />KING STUD <br />WD. FRAME WALL <br />SEALANT <br />PER PLAN <br />MOISTOP(SEE <br />DETAIL NO - <br />1/16' PLYWD. SHEATHING <br />FOR INSTALL) <br />WINDOW FRAME - <br />BLDG. PAPER <br />5EALA14T <br />51DING PER PLAN <br />TRIM PER ELEVATION <br />(WHERE APPLICABLE) <br />FORTIFLASH ON ALL <br />SIDES OF WINDOW <br />WINDOW JAMB DETAIL <br />�J SCALE: N.T.S. <br />LAP SIDING, U.NO. (HOLD 1-1,12' <br />OFF ADJOINING ROOF) <br />METAL FLASHING <br />(MAY BE STEPPED) <br />BUILDING PAPER ON <br />SHEATHING (SIDING CUT <br />/ <br />AWAY FOR CLARITY) <br />METAL RAIN DIVERTER (THE <br />PURPOSE 15 TO SHED THE <br />- <br />WATER OFF THE ROOF AND <br />KEEP IT AWAY FROM THE <br />/ <br />ROOF SHINGLES <br />VERTICAL WALL BENEATH). <br />! <br />PER SPEC. <br />FASCIA PER PLAN w/ <br />30u ROOF FELT <br />GUTTER <br />7/I6" OSB ROOF <br />SHEATHING <br />$NOTE: SEAL ALL <br />EXPOSED FASTENERS <br />DETAIL @ ROOF/WALL INTERSECTION <br />r� <br />N2 <br />SCALE: N.T.S. <br />INSULATION - -7/16' PLYWD. SHEATHING <br />(WHERE OCCURS) 6' FORTIFLASH 0/ FLASHING <br />WD. FRAME WALL SIDING PER PLAN <br />PER PLAN BUILDING PAPER <br />R-10 INSULATION MOISTOP (SEE DETAIL WHO <br />BEHIND HDR, TYP IF FOR INSTALL) <br />ALL HDR's MIN. 1/4' GAP BTWN SIDING <br />GYP BD. AND FLASHING <br />HEADER PER PLAN FLASHING TURN DOWN <br />V4' AT EACH END <br />TRIM PER ELEVATION <br />(SEES E1 (WHERE APPLICABLE) <br />WINDOW HT <br />,- SEALANT <br />SEALANT -WINDOW FRAME <br />WINDOW HEAD DETAIL <br />VV�O SCALE: N.T.S. <br />STUDS @ 16'. (NO POSTS/ <br />POINT LOADS ABOVE VENTS) <br />SIDING PER PLAN <br />'I BOTTOM SILL PLATE <br />3/4' T6G SUBFLOOR <br />FLASHING <br />I 7-V2"x15-1/2' CEDAR RIM <br />W i VENTS w/ GALV SCREEN - <br />I PROVIDE LOUVERED VENT5 <br />@ FRONT ELEVATIONS <br />RIM PER PLAN <br />P.T. MUD SILL <br />CONCRETE FOUNDATION <br />$*DO NOT INSTALL VENT(5) CLOSER THAN 3' TO GAS METERss <br />$$BUILDING PAPER SHOULD BE INSTALLED OVER FLASHINGss <br />NOTE: PER WSEC R402.2.7: WHEN FOUNDATION VENTS ARE NOT PLACED 50 THAT THE TOP <br />OF THE VENT 15 BELOW THE LOWER SURFACE OF THE FLOOR INSULATION, A PERMANENTLY <br />ATTACHED BAFFLE SHALL BE INSTALLED AT AN ANGLE OF 30' FROM HORIZONTAL, TO <br />DIVERT AIR FLOW BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. <br />FOUNDATION VENT <br />WI SCALE: N.T.S. <br />
The URL can be used to link to this page
Your browser does not support the video tag.