My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9916 18TH AVE W B 2023 Plans 2025-02-03
>
Address Records
>
18TH AVE W
>
9916
>
Plans
>
9916 18TH AVE W B 2023 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 3:38:30 PM
Creation date
2/3/2025 3:36:19 PM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9916
Unit
B
Permit
B2308-067
Year
2023
Notes
NEW TOWNHOUSE COMMUNITY - BENTON SQUARE BUILDING B, UNIT B
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIR BARRIER REQUIREMENT 9 <br /> PER 2018 WASHINGTON STATE ENERGY CODE R402.4 A CONTINUOUS AIR BARRIER m 'F <br /> r-t.J SHALL BE INSTALLED IN THE BUILDING ENVELOPE.EXTERIOR THERMAL ENVELOPE <br /> CONTAINS A CONTINUOUS AIR BARRIER.BREAKS OR JOINTS IN THE AIR BARRIER SHALL .+ 3 <br /> BE SEALED.AIR PERMEABLE INSULATION SHALL NOT BE USED AS AS A SEALING <br /> MATERIAL. ¢� <br /> PROVIDE BUILDING AIR LEAKAGE TESTING WITH APPROVED BLOWER DOOR PER <br /> ]]46G.W.B. <br /> G G.W.B.TAPED TO WALL INFORMATION BELOW.SUBMIT TESTING RESULTS TO JURISDICTION FOR APPROVAL. <br /> SEAL G.W.B PE <br /> O OORBWINDOWER <br /> D BLOWER DOOR TEST � <br /> OPENINGS <br /> 2018 Washington State Energy Code(WSEC)section R402.4.1.2 requires air leakage testing for a o 3 <br /> SEAL G.W.B.TO TOP I I SEAL G.W.B.PERIMETER all new houses and additions.The requirement is met if the structure has a leakage rate of 5 air o <br /> PLATE AT ALL EXTERIOR OF DOOR&WINDOW changes per hour when depressurized with a blower door to 50 Pascals or less(5ACH50).A — <br /> WALLS I I OPENINGS Pascal is a measurement of pressure.249 Pascals are equal to 1"of water column.The test must <br /> G.W.B.CAULKED TO TOP PLATE be performed using a Blower Door device which consists of a large fan,a frame and panel.A <br /> II I manometer(pressure gauge)is used to read house and fan pressures. <br /> SHADED it I I I I WSEC states that the test may be performed at any lime after rough in.All penetrations in the <br /> COMPONENTS I I I building envelope must be sealed including those for Wililies,plumbing,elearicel,ventilation and <br /> INDICATE ELEMENTS I combustion appliances.The code also states that when required by the building official,the test jl� <br /> COMPRISING THE shall be conducted by an approved third party.CONTINUOUS AIRBARRIER ENCLOSURE To cendua the test1.Close all windows,doors and fireplace and stove doors.2.Close all dampers including exhaust,intake,make-up air,backdraft and <br /> G.W.B.CAULKED TO BOTTOM PLATEflue dampers.Since you will be depressurizing the house,dampers in bath •�fans,etc.will be sucked closed during the test antl will therefore notnegatively affect the results. <br /> BOTTOM PLATE CAULKED OR GASKETED I I I I 3.Make sure plumbing traps are filled with water. <br /> TO SUBFLOOR/CONCRETE SLAB AT 4.Leave doors between healed areas open. I <br /> SLAB ON GRADE CONDITIONS I I I i 5.Open access hatches to conditioned attics and/or conditioned crawl <br /> I I I I spaces.Leave hatches closed if these are unconditioned areas. <br /> 6.Seal exterior openings for continuously operating ventilation systems and JL <br /> RIM JOIST CAULKED,GLUED OR I heat recovery ventilators. <br /> GASKETED TO SUBFLOOR I 7.Turn off heating and cooling systems but do not seal supply or return <br /> registers. <br /> Adjust all combustion appliances so that they do not turn on during the <br /> I test. <br /> RIM JOIST CAULKED,GLUED OR I 9.Install the blower door in an exterior door opening and connect hoses from <br /> GASKETED A TOP PLATE the manometer to the blower door fan and the exterior pressure tap.See <br /> / i in instructions for correct set-up. <br /> SEAL G.W.B.TO FIRST 10.Depressurize the house to-50 Pascals. <br /> SEAL G.W.B.TO TOP STUD AT INTERIOR 11.Record the now rate(with simple manometers,the fan pressure(Pa)is <br /> G.W.B.CAULKED TO TOP PLATE PLATE WHEN ADJACENT PARTUTIONS converted to.CFMw using a now table.Many digital manometers sold with <br /> TO UNCONDITIONED I blower doomcan automatically perform this conversion,and display <br /> ATTIC I CFMso directly.)Consult your blower door and manometer manuals. <br /> / w You now must convert the flow rate(CFMso I to ACHeo. <br /> IUse the following formula: <br /> ACHw=(CFM so X 60)/Volume Q <br /> SEAL G.W.B.TO SILL Where- m <br /> PLATE AT ALL EXTERIOR ACH w=Air Changes per Hour at-50 Pascals <br /> G.W.B.CAULKED TO BOTTOM PLATE WALLS SEAL ALONG INSIDE OF CFMeo X 60=Converts Cubic Feet per Minute to Cubic Feet per <br /> BOTTOM OF FIRST STUD Hour <br /> AT INTERIOR WALL OR Volume=Condifioned floor area of the housing unit multiplied by <br /> BOTTOM PLATE CAULKED OR GASKETED HOLD BACK FIRST STUD the tailing height <br /> TO SUBFLOOR/CONCRETE SLAB AT AND RUN G.W.B. <br /> SLAB ON GRADE CONDITIONS CONTINUOUS Example:A blower door test has be.en done on a 2,000 square foot house <br /> and the fan flow(CFM50)rate is 1100 CFM. <br /> ALL ELECTRICAL PENETRATIONS AT EXTERIOR ACHm=(CFM50 X 60)[Volume <br /> -- eo=(11 00 X 60)/(2000 X 8) <br /> GASKETED TO RIM JOIST WALLS TO USE AIR-SEALED BOXES.ALL WIRE ACHeo=66,000/16,000 <br /> OPENINGS&PENETRATIONS SEALED WITH ACHeo=4.1 <br /> CAULK,PUTTY OR INTEGRAL SEAL. <br /> RIM JOIST CAULKED OR GASKETED Since the code requires the AC Wo to be less than 4,this house complies with an <br /> TO SILL PLATE SEAL G.W.B.TO BOX FLANGE WITH ACHw of 4.1.Record the ACHeo on the energy certificate on or near the electrical <br /> CONTINUOUS BEAD OF CAULK OR ADHESIVE. panel. <br /> P.T.SILL PLATE INSTALLED <br /> OVER CONTINUOUS SILL GASKET W <br /> Cc r <br /> Q J <br /> L = <br /> 9 <br /> LU <br /> ZN <br /> N , <br /> G.W.B AIR BARRIER-CONCEPTUAL EXTERIOR : ALL SECTION G.W.B AIR BARRIER-CONCEPTUAL ISOMETRIC O w <br /> o <br /> Z <br /> W U OL <br /> m <br /> H CONCEPTUAL INTERIOR AIR BARRIER SYSTEM-GYPSUM WALL BOARD(G.W.B.)METHOD <br /> a N.T.S. <br /> E b <br /> . G.W.B.ADHESIVE ON I SEALANT OR ADHESIVE <br /> 3 BOTH SIDES OF FIRST CONTINUOUS BEAD SUBFLOOR ADHESIVE <br /> Mk v <br /> INTERIOR STUD , <br /> JOB NO.: <br /> 22205 <br /> G.W.B.ADHESIVE \ I SEALANT OR ADHESIVE .=PLOT DATE <br /> AT BOTTOM AND 12/SY2023 2:30:38 PM <br /> m CONTINUOUS SEALANT AT / TOP OF STUD - <br /> 1. FIXTURE PERIMETER TO DATE: OB/08/2023 <br /> G.W.B. 6 SCALE: 1„.1'-0" <br /> I.C.RATED RECESSED ` E DRAWN: MB <br /> G.W.B.ADHESIVE <br /> LIGHT FUTURE - - AT BOTTOM AND CHCKD: TM <br /> TOP OF PLATE GENERAL SHEETS <br /> o SHEET NO.: <br /> SEALING AT RECESSED FIXTURES SEALING AT INTERSECTING WALLS SEALING AT RIM JOIST xA 19 <br /> 3 N.T.S. 4 N.T.S. 5 N.T.S. <br />
The URL can be used to link to this page
Your browser does not support the video tag.