0
<br /> CLADDING PER ELEVATIONS -CLADDING PER ELEVATIONS m C
<br /> WEAT7-777777777
<br /> HER RESISTANT BARRIER,LAP OVER PRE a m
<br /> �q( a a
<br /> •!� '� STRIPPING AT WINDOW OPENING --- R-10 HEADER INSULATION
<br /> FIBER CEMENT PANEL FIBER CEMENT LAP SIDING " 3
<br /> CONTINUOUS SEALANT AT CLADDING PER
<br /> ELEVATION KEYNOTES, PER ELEVATION KEYNOTES
<br /> SEALANT BETWEEN W.R.B.B GWB TO FRAMING a<
<br /> PERIMETER FOR AIR LOCATE JOINTS AS 4
<br /> PERIMETER SEAM TAPE OR S.A.M. BARRIER CONTINUITY INDICATED ON m
<br /> CO ARCHITECTURAL Z NTINUOUS SEALANT AT
<br /> ELEVATIONS
<br /> GWB TO FRAMING - 24 GA PREFINISHED CONTINUOUS DRIP COMPATIBLE EXTRUDED
<br /> PERIMETER FOR AIR FLASHING,MIN.3"LEG&UPTURNED END DAMS ALUMINUM HORIZONTICAL FIBER TAL TRIM
<br /> BARRIER CONTINUITY _ PANEBY LMANUFACTURER.EPRE-
<br /> _— -W.R.B.SEAM TAPE OR SELF- ��� ��
<br /> W.R.B.SEAM TAPE OR WEATHER BARRIER, „ PRIMED,FIELD PAINT TO ) _
<br /> ADHERING RESILIENT FLASHING LAP 12"MIN.AT CORNER MATCH ADJACENT CLADDING \' S
<br /> SELF-ADHERING RESILIENT FLASHING : COMPATIBLE EXTRUDED c c
<br /> SIDE OF R.01$ TOP OF R.O� ALUMINUM VERTICAL TRIM BY o
<br /> V FIBER CEMENT PANEL
<br /> COMPATIBLE EXTRUDED ALUMINUM VERTICAL MANUFACTURER.PRE- WEATHER BARRIER r --ate 0 3
<br /> TRIM BY FIBER CEMENT PANEL WINDOW TRIM,SIZE PER ELEVATIONS PRIMED,FIELD PAINT TO u
<br /> MATCH ADJACENT CLADDING FIBER CEMENT PANEL
<br /> MANUFACTURER COMPATIBLE EXTRUDED CLADDING PER ELEVATION =_`
<br /> BACKER ROD 8 SEALANT WEATHER BARRIER ALUMINUM OUTSIDE KEYNOTES,LOCATE JOINTS <�a
<br /> BACKER ROD&SEALANT CORNER BY FIBER AS INDICATED ON
<br /> GYPSUM WALLBOARD WITH PVA PRIMER -GYPSUM WALLBOARD WITH PVA PRIMER FIBER CEMENT PANEL CEMENT PANEL L ARCHITECTURAL ELEVATIONS
<br /> CLADDING PER ELEVATION MANUFACTURER.PR
<br /> PVC WINDOW PER WINDOW SCHEDULE, -PVC WINDOW PER WINDOW SCHEDULE, PRIMED,FIELD PAINT TO
<br /> KEYNOTES,LOCATE JOINTS AS � o
<br /> INSTALL PER MANUFACTURER'S MATCH ADJACENT -
<br /> INSTALL PER MANUFACTURER'S INDICATED ON ARCHITECTURAL
<br /> RECOMMENDATIONS RECOMMENDATIONS CLADDING Y
<br /> ELEVATIONS
<br /> - r
<br /> 1 WINDOW JAMB-WITH PANEL 2 3 INDOW-HEAD WITH TRIM 8 LADDING-VERITCAL JOINT,FIBER CEMENT PANEL 4 a LADDING-OUTSIDE CORNER,FIBERT CEMENT PANEL 5 CLADDING-HORIZONTAL JOINT,FIBER CEMENT LAP TO PANEL
<br /> 5
<br /> CLADDING PER ELEVATIONS FIBER CEMENT PANEL
<br /> - - CLADDING PER ELEVATIONS CLADDING PER ELEVATION FIBER CEMENT CLADDING PER ELEVATION
<br /> KEYNOTES,LOCATE JOINTS AS FIBER CEMENT PANEL KEYNOTES.LAP SIDING SHOWN:FIBER
<br /> R-10 HEADER INSULATION -- CONTINUOUS SEALANT AT
<br /> INDICATED ON ARCHITECTURAL CLADDING PER CEMENT PANEL SIMILAR,PROVIDE ALUM.
<br /> GWB TO FRAMING ELEVATIONS ELEVA71ON KEYNOTES, HORIZONTAL TRIM STRIP AT BOTTOM
<br /> CONTINUOUS SEALANT AT PERIMETER FOR AIR
<br /> LOCATE JOINTS AS
<br /> GWB TO FRAMING PERIMETER FOR AIR
<br /> BARRIER CONTINUITY INDICATED ON
<br /> ARCHITECTURAL
<br /> CONT.24 GA MIN.PREFINISHED
<br /> I
<br /> BARRIER CONTINUITY I ,
<br /> WEATHER RESISTIVE BARRIER, ELEVATIONS THROUGH-WALL FLASHING,1/2"MIN.
<br /> SEALANT BETWEEN HEAD FLASHING 8 LAP OVER PRESTRIPPING AT COMPATIBLE EXTRUDED AIRGAP BETWEEN FLASHING&CLADDING
<br /> PERIMETER SEAM TAPE OR S.A.M. WINDOW OPENING
<br /> ALUMINUM VERTICAL J-
<br /> CHANNELS FIBER CEMENT
<br /> I WEATHER BARRIER, ADHERED MANUFACTURED STONE .,.
<br /> WEATHER RESISTANT BARRIER LAP OVER HEAD WINDOW TRIM,SIZE PER ELEVATIONS PANEL MANUFACTURER.PRE- LAP 12"MIN.AT CORNER WATERTABLE CAP,INSTALL PER
<br /> FLASHING WITH CONTINUOUS SEALANT PRIMED,FIELD PAINT TO MANUFACTURER REQUIREMENTS
<br /> Z/X I' W.R.B,SEAM TAPE OR MATCH ADJACENT CLADDING
<br /> SELF-ADHERING RESILIENT FLASHING `
<br /> WEATHER BARRIER,LOWER COURSE `.
<br /> TOP OF R.O. COMPATIBLE EXTRUDED TUCK UNDER THROUGH-WALL FLASHING
<br /> SIDE OF R.O
<br /> ---- ALUMINUM INSIDE '
<br /> 24'GA PREFINISHED CONTINUOUS DRIP CORNER BY FIBER �I z cn
<br /> CEMENT PANEL J
<br /> FLASHING MIN.3"LEG&UPTURNED END DAMS
<br /> 2 LAVERS BUILDING PAPER
<br /> BACKER ROO 85EALANT MANUFACTURER ()
<br /> W.R.B.SEAM TAPE OR SELF- I
<br /> WEATHER BARRIER
<br /> ADHERING RESILIENT FLASHING OR WEATHER BARRIER Q �f
<br /> GYPSUM WALLBOARD WITH PVA PRIMER MORTAR SCRATCH COAT ` 0
<br /> BACKER ROD&SEALANT FIBER CEMENT LAP SIDING PER W/EXPANDED METAL LATH
<br /> GYPSUM WALLBOARD WITH PVA PRIMER ELEVATION KEYNOTES ADHERED MANU-FACTURED STONE `� J w
<br /> PVC WINDOW PER WINDOW SCHEDULE, - VENEER PER ELEVATION KEYNOTES
<br /> PVC WINDOW PER WINDOW SCHEDULE, INSTALL PER MANUFACTURER'S V
<br /> INSTALL PER MANUFACTURER'S RECOMMENDATIONS
<br /> RECOMMENDATIONS
<br /> 6 WINDOW HEAD-WITH PANEL WINDOW JAMB-WITH TRIM p 3 LADDING-VERTICAL JOINT,FIBER CEMENT PANEL TO LAP 9 3 CLADDING-INSIDE CORNER,FIBER CEMENT PANEL 1 O CLADDING-HORIZONTAL JOINT,FIBER CEMENT LAP TO STONE
<br /> ADHERED MANUFACTURED STONE
<br /> VENEER PER ELEVATION KEYNOTES
<br /> -PVC WINDOW PER WINDOW SCHEDULE, MORTAR SCRATCH COAT W/ FIBER CEMENT PANEL
<br /> INSTALL PER MANUFACTURER'S FCLADDING PER ELEVATION
<br /> EXPANDED METAL LATH
<br /> CLADDING PER ELEVATIONS RECOMMENDATIONS KEYNOTES,LOCATE JOINTS
<br /> -CONTINUOUS SEALANT AT GWB TO FRAMING Iff F(2)LAYERS BUILDING PAPER OR AS INDICATED ONuj
<br /> R-10 HEADER INSULATION WEATHER BARRIER ARCHITECTURAL ELEVATIONS
<br /> PERIMETER FOR AIR BARRIER CONTINUITY FIBER CEMENT CLADDING
<br /> WEATHER RESISTIVE BARRIER, -- -GYPSUM WALLBOARD PER ELEVATION KEYNOTES---+ I..L
<br /> COMPATIBLE EXTRUDED C U
<br /> BY VERTICAL
<br /> ICAL FIBER
<br /> ER CEMENT Q O J
<br /> I LAP OVER HEAD FLASHING ALT:WOOD OR M.D.F.SILL ; BY VERTICAL FIBER CEMENT � � -
<br /> B APRON ATOWNER'S WEATHER BARRIER, PAN EL MANUFACTURER.PRE- L =
<br /> W.R.B.HEAD FLASHING A SELF- OPTION LAP 12"MIN.AT CORNER PRIMED,FIELD PAINT TO
<br /> ADHERING RESILIENT FLASHING,INSTALL TAPE ALL SEAMS MATCH ADJACENT CLADDING W p
<br /> PER MANUFACTURERS -SEALANT 3
<br /> RECOMMENDATIONS i r^
<br /> _, .O. V) W
<br /> i
<br /> 24 GA,PREFINISHED CONTINUOUS DRIP - - —BOTTOM OF R � WEATHER BARRIER,UPPER C7
<br /> FLASHING,MIN.3"LEG&UPTURNED END DAMS -—BACKER ROD&SEALANT COURSE LAP OVER COURSE 7
<br /> -DRAINAGE SHIMS A7 TOP&FRONT FACES BELOW L
<br /> i
<br /> TRIM,SIZE PER ELEVATIONS CONTINUOUS >
<br /> TOP OF R.O --SILL PLAN FLASHING WITH BACKDAM -------
<br /> -WINDOW W
<br /> ,. ___ ;P.T.
<br /> "... SEALANT ii i I '�-
<br /> ,. ~ O _
<br /> TRIM,SIZE PER ELEVATIONS
<br /> ' ,. " FIBER CEMENT LAP SIDING I
<br /> CONTINUOUS SEALANT AT - ,:-; .. .' U
<br /> .�' .. .. PER ELEVATION KEYNOTES I Q
<br /> GWB TO FRAMING - f
<br /> ---COMPATIBLE SEALANT ` U a
<br /> PERIMETER FOR AIR WD.OR FIBER CEMENT I
<br /> . 2'
<br /> BARRIER CONTINUITY X2 NOM.WD.TRIM S4S CORNERBOARDS,2X4 - W
<br /> SEALANT ---WEATHER RESISTIVE BARRIER, CONTINUOUS COMPATIBLE SEALANT NOMINAL,WEATHER-
<br /> 00
<br /> CUTBSEALALLJOINTS, _------------------------------
<br /> WITH
<br /> FILL ROUGH OPENING PERIMETER TUCK UNDER SILL LINER PAINT COLOR TO
<br /> CLOSED-CELL SPRAY FOAM - -CLADDING PER ELEVATIONS FIBER CEMENT LAP SIDING PER ELEVATION MATCH ADJACENT
<br /> DOORFRAME KEYNOTES CLADDING
<br /> IA
<br /> a EXTERIOR DOOR-HEAD WINDOW-SILL WITH TRIM CLADDING-VERTICAL JOINT,FIBER CEMENT LAP TO STONE CLADDING-OUTSIDE CORNER WITH CORNERBOARDS CLADDING-HORIZONTAL JOINT,FIBER CEMENT PANEL TO LAP
<br /> 11 3„=,, 12 3„=1, 13 3„=,, 14 3„=1' 15 ,,,_,,
<br /> z
<br /> E PVC WINDOW PER WINDOW SCHEDULE, y
<br /> INSTALL PER MANUFACTURER'S m
<br /> i RECOMMENDATIONS CONTINUOUS
<br /> COMPATIBLE SEALANT h
<br /> o OTHER RESISTIVEDING PER TBARRIER PERIMETER FOR AIR BARRIER CONTIT AT GWB TO ITY FRAMING O �'' o
<br /> E --GYPSUM WALLBOARD 2X2 NOM.WD. COMPATIBLE EXTRUDED N
<br /> s ALT:WOOD OR M.D.F.SILL ALUMINUM HORIZONTAL TRIM
<br /> c &APRON AT OWNER'S BY VERTICAL FIBER CEMENT a
<br /> CONTINUOUS SEALANT AT OPTION FIBER CEMENT CLADDING PANEL MANUFACTURER.PRE-
<br /> WEATHER BARRIER,UPPER PER ELEVATION KEYNOTES PRIMED,FIELD PAINT TO
<br /> GWB TO FRAMING
<br /> -SEALANT COURSE LAP OVER THROUGH- MATCH ADJACENT CLADDING O PERIMETER FOR AIR WALL FLASHING WEATHER BARRIER,
<br /> m
<br /> BARRIER CONTINUITY
<br /> BOTTOM OF R.O LAP 12"MIN.AT CORNER ?JOB NO.:
<br /> FIBER CEMENT CLADDING _ WEATHER BARRIER,UPPER
<br /> N TRIM,SIZE PER ELEVATIONS �- BACKER ROD&SEALANT PER ELEVATION KEYNOTES --- - COURSE LAP OVER COURSE 22208
<br /> -- COMPATIBLE EXTRUDED ALUMNIUM BELOW
<br /> HORIZONTAL EDGE TRIM BY FIBER CEMENTDATE
<br /> PANEL MANUFACTURER =PLOT 1/1702420241:37:49 PM
<br /> - DRAINAGE SHIMS AT TOP&FRONT FACES CONT.24 GA MIN.
<br /> �_
<br /> PREFINISHED THROUGH- FIBER CEMENT CLADDING
<br /> SEALANT SILL PLAN FLASHING WITH BACKDAM WALL FLASHING,INSTALL AT PER ELEVATION KEYNOTES DATE: 06/082023
<br /> E ---CLADDING PER ELEVATIONS EVERY 2 FLOORS OR 20'
<br /> 'u FILL ROUGH OPENING PERIMETER 1/2"MIN.AIRGAP BETWEEN _ SCALE: 3" 1'-0"
<br /> FLASHING&CLADDING
<br /> WITH CLOSED-CELL SPRAY FOAM --- COMPATIBLE SEALANT DRAWN: MB
<br /> DOORFRAME --- WEATHER RESISTIVE BARRIER, WEATHER BARRIER, CHCKD: TM
<br /> TUCK UNDER SILL LINER LOWER COURSE TUCK
<br /> UNDER THROUGH-WALL GENERAL SHEETS
<br /> A FLASHING :SHEET NO.:
<br /> EXTERIOR DOOR-JAMB WINDOW SILL-WITH PANEL CLADDING-THROUGH WALL FLASHING CLADDING-INSIDE CORNER,FIBER CEMENT LAP SIDING CLADDING-HORIZONTAL JOINT,FIBER CEMENT PANEL A23
<br /> 516 3„_,, 17 3„_,, — 18 3„_,, 19 3„_�' 20 3„_,,
<br />
|