My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3402 COLBY AVE 2025-03-27
>
Address Records
>
COLBY AVE
>
3402
>
3402 COLBY AVE 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 8:35:46 AM
Creation date
2/5/2025 11:20:00 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3402
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 1 3 4 5 <br /> GENERAL LEGEND ABBREVIATIONS PIPING LEGEND -COFFMAN <br /> ENGINEERS <br /> SYMBOL DESCRIPTION ABBR DESCRIPTION ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION <br /> 135 W.Fairhaven Ave <br /> ABV ABOVE L LENGTH LIGHT LINEWORK INDICATES 3 CAP PIPE END CAP Suite 102 <br /> A DETAIL SYMBOL: A = IDENTIFYING NUMBER AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE EXISTING PIPING OR EQUIPMENT <br /> B B = SHEET WHERE DETAIL IS SHOWN ADA AMERICANS WITH DISABILITIES ACT LBS POUNDS D PIPE TURNING DOWN OR AWAY Burlington,WA 98233 <br /> AHU AIR HANDLING UNIT LF LINEAR FOOT/FEET INDICATES PIPING OR EQUIPMENT <br /> AL ACOUSTIC LINED L G LEAVING TO BE REMOVED PIPE TURNING UP OR TOWARD ph 360.707.5656 <br /> A SECTION SYMBOL:A = IDENTIFYING LETTER AP ACCESS PANEL LVWG LO <br /> APO AIR PRESSURE DROP LWR LW WALL GRILLE ___SS___ SS SANITARY SEWER-OUTSIDE BUILDING AND PIPE TURNING DOWN OR AWAY(TEE) <br /> OW WALL REGISTER BELOW GROUND <br /> B B = SHEET WHERE SECTION IS SHOWN ARCH ARCHITECT/ARCHITECTURAL LWT LEAVING WATER TEMPERATURE __ REDUCER(NOT TYPICALLY SHOWN) www.coffman.com <br /> SD——— SD STORM DRAIN-OUTSIDE BUILDING AND <br /> ARV AUTOMATIC RELIEF VALVE or BELOW GROUND PIPE CONNECTION <br /> ACID RESTISTANT VENT MAX MAXIMUM <br /> SECTION CUT LINE INDICATOR ARW ACID RESTISTANT WASTE MBH 1000 BRITISH THERMAL W WASTE(8 SOIL)-ABOVE GROUND-INTERIOR <br /> UNITS PER HOUR ______ W WASTE(8 SOIL)-BELOW GROUND-INTERIOR PIPE ANCHOR <br /> D BDD BACKDRAFT DAMPER MCC MOTOR CONTROL CENTER (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) D ND N <br /> O KEYED REFERENCE NOTE OR SHEET NOTE BFP BACKFLOW PREVENTER ------- - V VENT �,a WA$a�L�'S <br /> MECH MECHANICAL ---- <br /> BHP BRAKE HORSEPOWER MFR MANUFACTURER = PIPE ALIGNMENT GUIDES <br /> POINT OF CONNECTION(POC)SYMBOL BG BELOW GROUND MIN MINIMUM - CW COLD WATER-DOMESTIC <br /> (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) ra o <br /> BJ BETWEEN JOISTS MISC MISCELLANEOUS -- HW HOT WATER-DOMESTIC <br /> P1-1 PLUMBING FIXTURE REFERENCE(REFER TO SCHEDULE) BTU BRITISH THERMAL UNIT M7D MOUNTED l" HB HOSE BIBB <br /> BTUH BRITISH THERMAL UNITS PER HOUR MTG MOUNTING --- HWC HOT WATER CIRCULATING-DOMESTIC .�31 <br /> NNI-1 EQUIPMENT IDENTIFICATION(REFER TO SCHEDULES) WH/ CO WALL HYDRANT or NON-FREEZE WALL HYDRANT <br /> C CENTIGRADE RD RD RAINWATER DRAINAGE-ABOVEGROUND rsel:l� <br /> O N/A NOT APPLICABLE __ �I CO/VJCO CLEANOUT or WALL CLEANOUT �q,�y$g'' <br /> A CC COOLING COIL N/C NORMALLY CLOSED —RD——— RD RAINWATER DRAINAGE-BELOW GROUND <br /> MEDICAL GAS OUTLET IDENTIFICATION REFER TO SCHEDULE CD CEILING DIFFUSER N/O NORMALLY OPEN � FCO/SCO FLUSH CLEANOUT or SURFACE CLEANOUT 12/15122 <br /> u ( ) CFM CUBIC FEET PER MINUTE NC NOISE CRITERIA ORD ORD RAINWATER DRAINAGE OVERFLOW-ABOVE GROUND <br /> ■ MEDICAL GAS ZONE VALVE STATION MOUNTED IN WALL CG CEILING GRILLE NIC NOT IN CONTRACT ———ORD——— ORD RAINWATER DRAINAGE OVERFLOW-BELOW GROUND FDC FIRE DEPARTMENT CONNECTION <br /> RR CI CAST IRON NTS NOT TO SCALE ,� <br /> CLG CEILING D D DRAIN-INDIRECT FIRE SPRINKLER ALARM GONG <br /> MEDICAL GAS ALARM PANEL MOUNTED IN WALL CO CLEANOUT CA OUTSIDE AIR -----RV----- RV RELIEF VALVE VENT <br /> CONC CONCRETE OBD OPPOSED BLADE DAMPER <br /> CONN CONNECT or CONNECTION O/C ON CENTER PIPE SLOPE DIRECTION ® AD AREA DRAIN <br /> CONST CONSTRUCTION OD OUTSIDE DIAMETER ® FD or FFD FLOOR DRAIN or FUNNEL FLOOR DRAIN <br /> I-+ MEDICAL GAS OUTLET CONT CONTINUATION RL RL LIQUID LINE-REFRIGERANT <br /> OD <br /> OPENING <br /> CR CONDENSATE RETURN RS RS SUCTION LINE-REFRIGERANT ® FS FLOOR SINK <br /> PCV PRESSURE CONTROL VALVE Q OD OVERFLOW DRAIN <br /> DB DECIBLE or DRY BULB PD PRESSURE DROP G G NATURAL GAS <br /> REVISION CLOUD AND REVISION NUMBER DDC DIRECT DIGITAL CONTROL PH orO PHASE O RD ROOF DRAIN <br /> DIA DIAMETER PLCS PLACES ATV AN ATMOSPHERIC VENT <br /> DIM DIMENSION POC POINT OF CONNECTION SHUTOFF VALVE(AS SPECIFIED FOR PIPING SYSTEM) <br /> DN DOWN POUA POINT OF USE ALARM D87 BV BALL VALVE <br /> XX BINARY(YES/NO)SENSING SWITCH DPR DAMPER PRV PRESSURE REDUCING VALVE TJ CKV CHECK VALVE COLBY AVE <br /> (PIPE OR DUCT MOUNTED) DWG DRAWING PSI POUNDS PER SQUARE INCH <br /> PSIG POUNDS PER SQUARE INCH GAGE IYI BFV BUTTERFLY VALVE <br /> E-,00 EXHAUST AIR MS APARTMENTS <br /> XX BINARY(YES/NO)SENSING SWITCH NUMBER INDICATES CFM QUANTITY R-100 RETURN AIR <br /> (SURFACE MOUNTED) EA EACH NUMBER INDICATES CFM QUANTITY I�I BFV BUTTERFLY VALVE W/MEMORY STOP 3402 COLBY AVE SE <br /> EAT ENTERING AIR TEMPERATURE RA RETURN AIR Db BAL VA BALANCING VALVE <br /> EF EXHAUSTFAN EVERETT, WA <br /> XX ANALOG SENSING DEVICE RAG RETURN AIR GRILLE pFl BSV COMBINATION BALANCING/SHUTOFF VALVE <br /> EG EXHAUST GRILLE <br /> (PIPE OR DUCT MOUNTED) READ REQUIRED <br /> ELEC ELECTRIC or ELECTRICAL RPBP REDUCED PRESSURE BACKFLOW ACV 2-WAY MODULATING CONTROL VALVE W/ACTUATOR 98201 <br /> C ELEV ELEVATION PREVENTOR C <br /> XX ANALOG SENSING DEVICE E ENERGY MANAGEMENT CONTROL SYSTEM ACV 3-WAY MODULATING CONTROL VALVE W/ACTUATOR <br /> (SURFACE MOUNTED) ESP <br /> EXTERNAL STATIC PRESSURE RPM REVOLUTIONS PER MINUTE <br /> EWT ENTERING WATER TEMPERATURE 2-POSITION CONTROL VALVE <br /> ® ANALOG SENSING DEVICE(SURFACE MOUNTED) EXH EXHAUST S-100 SUPPLY AIR <br /> (APPROPRIATE FOR MEASURED FLUID) EXST or(E) EXISTING NUMBER INDICATES CFM QUANTITY pFj PRV PRESSURE REDUCING VALVE <br /> SUBSCRIPT LETTER(X)INDICATES: SA SUPPLY AIR <br /> A-ALARM PRESSURE SENSOR F FAHRENHEIT SF SUPPLY FAN C9 RV RELIEF VALVE <br /> D.DIFFERENTIAL PRESSURE FA FACE AREA BHT SHEET CI FMS FLOW MEASUREMENT STATION <br /> F-FLOW RATE FCO FLOOR CLEANOUT SIM SIMILAR <br /> H-HUMIDITY FCU FAN COIL UNIT SP STATIC PRESSURE FSI STIR Y-TYPE STRAINER <br /> L-LOWLIMIT FD FLOOR DRAIN SQ SQUARE <br /> P-PRESSURE STATIC FDPR FIRE DAMPER $Q FT SQUARE FOOT/FEET Do GLV GLOBE VALVE <br /> ( ) FFD FUNNEL FLOOR DRAIN SS STAINLESS STEEL <br /> T-TEMPERATURE STD STANDARD OSY VA OUTSIDE SCREW AND YOKE VALVE <br /> V-VELOCITY&VOLUME FLOW RATE FF FINAL FILTER ® <br /> FLR FLOOR THK THICK Db EXP VA EXPANSION VALVE <br /> FPS FEET PER MINUTE TP TRAP PRIMER or TEST PLUG <br /> FPS FEET PER SECOND FT FOOT/FEET TYP TYPICAL FCV FLOW CONTROL VALVE FV FACE VELOCITY TU TERMINAL UNIT I�I UNION <br /> GA GAGE or GAUGE UBC UNIFORM BUILDING CODE <br /> GAL GALLON UFC UNIFORM FIRE CODE FLANGES <br /> GALV GALVANIZED UFAS UNIFORM FEDERAL ACCESSIBILITY STANDARDS <br /> GPH GALLONS PER HOUR UMC UNIFORM MECHANICAL CODE THREADED DRAIN PLUG <br /> GPM GALLONS PER MINUTE UPC UNIFORM PLUMBING CODE <br /> UG UNDERGROUND I MALE(GARDEN)HOSE CONNECTION WITH CAP <br /> H HEIGHT UH UNIT HEATER <br /> 4 TP TEST PLUG <br /> HD HEAD <br /> HP HORSEPOWER VA VALVE <br /> HTG HEATING VAC VACUUM SHOCK ARRESTOR PERMIT SET <br /> HVAC HEATING,VENTILATION AND VAV VARIABLE AIR VOLUME <br /> AIR CONDITIONING VD VOLUME DAMPER I[j T <br /> HWG HIGH WALL GRILLE VEL VELOCITY T TH or TI THERMOMETER(TEMPERATURE INDICATOR) <br /> HWR HIGH WALL REGISTER VFD VARIABLE FREQUENCY DRIVE <br /> HZ HERTZ VTR VENT THRU ROOF II BSTR BASKET STRAINER <br /> B ID INSIDE DIAMETER W WIDE �P PI PRESSURE INDICATOR B <br /> IE INVERT ELEVATION W/ WITH <br /> IN INCH or INCHES W/O WITHOUT <br /> INSUL INSULATION WB WET BULB AAV AUTOMATIC AIR VENT <br /> INV INVERT WCO WALL CLEANOUT <br /> WG WATER GAGE p <br /> KW KILOWATT WGE WASTE GAS EVACUATION T MANUALAIRVENT <br /> KWH KILOWATT HOUR WPD WATER PRESSURE DROP <br /> o WSEC WASHINGTON STATE ENERGY CODE <br /> 0 <br /> WT WEIGHT PUMP(DIAGRAM) <br /> FLEXIBLE CONNECTOR <br /> DRAWING INDEX <br /> DWG.NO. TITLE Zr INDICATES ASSEMBLY OF PIPING COMPONENTS REV DATE DESCRIPTION <br /> (AS NOTED OR DIAGRAMED) <br /> 0 <br /> P0.0 PLUMBING COVER SHEET 8 GENERAL INFORMATION PROD.NO. 222534 <br /> P0.1 PLUMBING SPECIFICATIONS <br /> r�3 P0.2 PLUMBING SCHEDULES DRAWN NH <br /> P0.3 PLUMBING SCHEDULES CHECKED BN <br /> P1.0 UNDERGROUND PLUMBING PLAN <br /> DATE 12/16/22 <br /> P1.1 GARAGE LEVEL PLUMBING PLAN <br /> o P1.2 GROUND FLOOR PLUMBING PLAN <br /> P1.3 SECOND FLOOR PLUMBING PLAN ©COFFMAN ENGINEERS INC. <br /> 3 P1.4 THIRD FLOOR PLUMBING PLAN SHEET TITLE: <br /> P1.5 FOURTH FLOOR PLUMBING PLAN <br /> P1.7 PLUMBING ROOF PLAN PLUMBING <br /> P2.1 ENLARGED PLUMBING PLANS COVER SHEET <br /> P2.2 ENLARGED PLUMBING PLANS <br /> o A P2.3 ENLARGED PLUMBING PLANS A <br /> P2.4 ENLARGED MECHANICAL ROOM PLAN <br /> P3.1 PLUMBING DETAILS <br /> P3.2 PLUMBING DETAILS <br /> u P3.3 PLUMBING DETAILS <br /> a <br /> P4.1 DOMESTIC WASTE&VENT RISER DIAGRAM <br /> m P4.2 DOMESTIC WASTE&VENT RISER DIAGRAM <br /> SHEET NO: <br /> 8 P4.3 DOMESTIC WATER RISER DIAGRAM <br /> 0 P0 .0 <br /> cz <br /> SHEET CF <br /> 1 2 3 4 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.