Laserfiche WebLink
• <br /> KAER <br /> PER ANENTE <br /> Project <br /> Kaiser Permanente Everett <br /> Medical Clinic Expansion <br /> 2929 PINE STREET <br /> EVERETT,WA 98201 <br /> Prepared for <br /> KAISER FOUNDATION <br /> EF-7A EF-7B HEALTH PLAN, INC. <br /> ISOLATION ISOLATION <br /> ROOMS ROOMS <br /> ROOF <br /> M M <br /> S <br /> COMBINATION FIRE/SMOKE <br /> DAMPER AT SHAFT(TYP) kil <br /> LEVEL4 Hellmuth,Obata&Kassabaum,Inc. <br /> 1218 Third Avenue,Suite 1315 <br /> Seattle,WA 98101 USA <br /> t+1 206 493 1771 f+1 206 493 1778 <br /> All reproduction&intellectual property rights reserved <br /> 2019 <br /> In Association with <br /> Mortensen <br /> General Contractor <br /> 10230 NE Points Drive,Suite 300 <br /> Kirkland,WA 98033 <br /> ConXtech,Inc <br /> Structurel Fabricator <br /> 6701 Koll Center Parkway,Suite 150 <br /> LEVEL 3 Pleasanton,CA 94566 <br /> KPFF Consulting Engineers <br /> Civil t Structural Engineering <br /> M <br /> LOUVER AT 1601 Fifth Avenue,Suite 1600 <br /> TECH DOCK Sea[[le,WA 98101 <br /> EF-1,30 0 CFM MaZZettl <br /> 30 <br /> MEP+FP Engineering <br /> 2013 4th Avenue,Suite 200 <br /> M Seattle,WA 98121 <br /> LOUVER AT <br /> � TECH DOCK <br /> EF-5 EF-4 Key Plan <br /> REFER TO GARAGE PACKAGE <br /> GROSSING STAINING STORAGE CART SPD SPD SPD 1,500 CFM 330 CFM FOR CANYON HVAC SYSTEMS <br /> STATION STATION CABINET WASHER WASHER WASHER WASHER <br /> LEVEL 2 L2-ROOF <br /> PATHOLOGY STERILE PROCESSING DEPARTMENT <br /> M <br /> M <br /> LOUVER AT <br /> �TECH DOCK EF-9 <br /> EF-8 1000 CFM <br /> 1,000 CFM <br /> T� CANYON ROOF <br /> �-IMI M LOUVER AT M <br /> PROVIDE ROOM l" —�— TECH DOCK <br /> EF-3 <br /> PRESSURE MONITOR 1,000 CFM Professional Seals <br /> CAFE <br /> FOR ISOLATION ROOM <br /> WITH LOCAL DISPLAY, ANTE ISO MRI MRI EMER HOT LAB UPTAKE EVS <br /> CONNECT TO DDC ROOM ROOM RETURN EXHAUST ROOM Q,4"p1r w,1s <br /> LEVEL 1 AIR I LEVEL 1 <br /> ISOLATION ROOM % z <br /> PROVIDE OXYGEN MONITORING SYSTEM <br /> WITH LOCAL VISUAL DISPLAY AND 24672 9 <br /> AUDIBLE ALARM.CLOSE RETURN AIR 'RFOIST <br /> DAMPER AND START EXH FAN WHEN TONAL <br /> OXYGEN FALLS BELOW SAFETY LEVELS <br /> No. Description Data <br /> SCHEMATIC DESIGN 2020/01/24 <br /> DESIGN DEVELOPMENT 2 02 010 511 5 <br /> DESIGN DEVELOPMENT ADDENDUM 2020/06/08 <br /> 50%CONTRACT DOCUMENTS 2020/07/31 <br /> 75%CONTRACT DOCUMENTS 2020/09/25 <br /> PERMIT SET 2020/11/13 <br /> ISSUED FOR CONSTRUCTION 2021/03/19 <br /> BASEMENT BASEMENT <br /> DIAGRAMS -AIRFLOW <br /> M512 NONE <br /> KIP Project No: CAP020407 <br /> HOK Project No: 19.05002.03 <br /> Sheet Title: <br /> AIRFLOW DIAGRAM <br /> a <br /> original ie 30 x 42.Do not scaly contents or this drawing. <br /> Sheet Number <br /> M M512 <br />