Laserfiche WebLink
• <br /> • • <br /> R �F MWFRS Wind Loads Job No: Taylor <br /> ASCE 7-10 Designer: WD <br /> Enclosed&Partially Enclosed Buildings of All Heights Checker: <br /> (- Notes: Taylor Storage Date: 10/16/2014 <br /> Basic Parameters <br /> Risk Category I Table 1.5-1 <br /> Basic Wind Speed,V 110 mph Figure 26.5-1A <br /> Wind Directionality Factor,Ka 0.85 Table 26.6-1 <br /> Exposure Category C Section 26.7 <br /> Topographic Factor,K„ 1.00 Section 26.8 <br /> Gust Effect Factor,G or Gf 0.836 Section 26.9 <br /> Enclosure Classification Enclosed Section 26.10 <br /> Internal Pressure Coefficient,GCp, +/-0.18 Table 26.11-1 <br /> Terrain Exposure Constant,a 9.5 Table 26.9-1 <br /> Terrain Exposure Constant,z, 900 ft Table 26.9-1 <br /> Wall Pressure Coefficients <br /> Windward Wall Width,B 24 ft <br /> Side Wall Width,L 10 ft <br /> L/B Ratio 0.42 <br /> Windward Wall Coefficient,C,, 0.80 Figure 27.4-1 <br /> Leeward Wall Coefficient,C,, -0.50 Figure 27.4-1 <br /> Side Wall Coefficient,C,, -0.70 Figure 27.4-1 <br /> Roof Pressure Coefficients <br /> Roof Slope,0 9.5` <br /> Median Roof Height,h 17 ft <br /> Velocity Pressure Exposure Coef.,Kt, 0.87 Table 27.3-1 <br /> Velocity Pressure,q,, 22.9 psf Equation 27.3-1 <br /> h/L Ratio 1.70 <br /> Windward Roof Area 0 ft' <br /> Roof Area Within 9 ft of WW Edge 0 ft' <br /> Location Min/Max <br /> Horiz Distance From Windward Edge <br /> Oft 9ft 17ft 34ft <br /> Windward Roof Coefficient Min -1.30 -1.30 -0.70 -0.70 Figure 27.4-1 <br /> Normal to Ridge,Cp Max -0.18 -0.18 -0.18 -0.18 <br /> Leeward Roof Coefficient Min -1.30 -1.30 -0.70 -0.70 <br /> Normal to Ridge,C,, Max -0.18 -0.18 -0.18 -0.18 <br /> Roof Coefficient Min -1.30 -1.30 -0.70 -0.70 <br /> Parallel to Ridge,CP Max -0.18 -0.18 -0.18 -0.18 <br /> Structure Pressure Summary(Add Internal Pressure q.GCr,or a,GC.as Necessary). <br /> Roof <br /> Walls Normal to Ridge Parallel Internal <br /> Height,z K, q, <br /> WW LW WW+LW Side WW LW to Ridge Positive Negative <br /> 0 ft 0.85 22.4 psf 14.9 psf 24.5 psf 4.1 psf <br /> 2 ft 0.85 22.4 psf 14.9 psf 24.5 psf Min: Min: Min: 4.1 psf <br /> 3 ft 0.85 22.4 psf 14.9 psf 24.5 psf -24.9 psf -24.9 psf -24.9 psf 4.1 psf <br /> 5 ft 0.85 22.4 psf 14.9 psf 24.5 psf 4.1 psf <br /> 7 ft 0.85 22.4 psf 14.9 psf 24.5 psf 4.1 psf <br /> 9 ft 0.85 22.4 psf 14.9 psf -9.6 psf 24.5 psf -13.4 psf 4.1 psf -4.1 psf <br /> 10 ft 0.85 22.4 psf 14.9 psf 24.5 psf 4.1 psf <br /> 12 ft 0.85 22.4 psf 14.9 psf 24.5 psf Max: Max: Max: 4.1 psf <br /> 14 ft 0.85 22.4 psf 14.9 psf 24.5 psf -3.5 psf -3.5 psf -3.5 psf 4.1 psf <br /> 15 ft 0.85 22.4 psf 15.0 psf 24.6 psf 4.1 psf <br /> 17 ft 0.87 22.9 psf 15.3 psf 24.9 psf 4.1 psf <br /> Page 1 of 1 <br />