My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3224 RUCKER AVE 2025-03-25
>
Address Records
>
RUCKER AVE
>
3224
>
3224 RUCKER AVE 2025-03-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 8:06:42 AM
Creation date
2/7/2025 10:36:53 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3224
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MASTER CONTRACT: 266909 MASTER CONTRACT: 266909 BLUE RAVEN <br /> REPORT: 70131735 Page No: 6 REPORT: 70131735 Page No: 9 <br /> PROJECT: 80136577 Date Issued:August 12,2022 PROJECT: 80136577 Date Issued:August 12,2022 1403 N.Research Way <br /> Orem,UT 84097 <br /> 800.377.4480 <br /> WWW.BLUERAVENSOLAR.COM <br /> SM and ULA markings <br /> 1. The system does not employ a maximum number of modules that can be installed per system. CONFIDENTIAL-THE INFORMATION <br /> Y P Y p Y HEREIN CONTAINED SHALL NOT BE <br /> The following markings appear on the rail by adhesive label: 2. Module Orientation: USED FOR THE BENEFIT OF ANYONE <br /> a. SM&ULA-Portrait OY LandSCa e EXCEPT BLUE RAVEN SOLAR NOR <br /> Il SHALL IT BE DISCLOSED IN WHOLE OR <br /> I. Submitter's name and/or CSA Master Contract number"266909"; b. RM5&DT—Landscape IN PART TO OTHERS OUTSIDE <br /> 2. Model designation; a. GFT—Portrait ECIPIENTS CO CONNECTION WITH THIE ON SALE EXCEPT N AND <br /> 3. Manufacturing date; d. NXT Horizon-Portrait or Landscape USE OF THE RESPECTIVE EQUIPMENT, <br /> was evaluated for use with modules stem u WITHOUT THE WRITTEN PERMISSION <br /> 4. System fire class rating/designation of information location in Installation Manual; 3. The system p to: OF BLUE RAVEN SOLAR LLC. <br /> 5. Design load rating/designation of information location in Installation Manual; a. SM&ULA—27.12 sq ft <br /> b. RM5&DT—27.76 sq ft <br /> The following markings appear on the Mid clamp by stamping: c. GFT-Portrait-27.12 sq ft NABCEP <br /> d. NXT Horizon—27.76 sq ft C E RT I F I E D <br /> 1. Submitter's name and/or CSA Master Contract number"266909"; 4. See Table 1 for customer supplied information for SM <br /> 2. CSA mark 5. See Table 2 for customer supplied information for ULA PV INSTALLATION <br /> 3. Mil ID for factory location 6. See Table 3 for customer supplied information for RM PROFESSIONAL <br /> 7. See Table 4 for customer supplied information for GFT Scott Gurney <br /> 8. See Table 5 for customer supplied information for NXT Horizon #PV-011719-015866 <br /> Nameplate adhesive label material approval information: 9. See the attached installation manual for each model installation instructions,and system drawings. CONTRACTOR: <br /> SATO AMERICA INC,SF401 DuraMark Polyester,MH48415 -Printing Materials—Component,UL 969- The critical components identified below may be formed at other locations and shipped directly BRS FIELD OPS <br /> Marking and Labeling Systems to the construction site provided they are made with the material/coatings identified and conform 385-498-6700 <br /> to the physical dimensions described and shown in their respective illustrations.Physical <br /> RM 5 South and RM DT markings specimens may not be present at the location where the CSA mark is applied. Location of <br /> markings can be found in the Marking section of this report. <br /> The following markings appear on the ballast bay by permanent stamping: <br /> 1. Submitter's name and/or CSA Master Contract number"266909"; Table 1 <br /> 2. Model designation; <br /> 3. Manufacturing date; MODULE RACKING SYSTEM TYPE/S <br /> 4. System fire class rating/designation of information location in Installation Manual; Model SM <br /> 5. Design load rating/designation of information location in Installation Manual; Module Fire Type.............................: Class A with Type 1,2,3 (with metallic frame),4(with trim), <br /> 5 (with trim), 10(with metallic frame), 19,22,25,29,or 30 for <br /> steep slope.Tested at 5"interstitial gap,the rating obtained for a <br /> 7"ACR <br /> 5-inch(127 mm)gap can be used for any other gaps allowed by <br /> UNIRAC RM SOUTH 5 the mounting instructions,per section 15 ofUL 2703 <br /> CONFORMS TO UL STD 2703 p Max branch circuit overcurrent- 30 <br /> PATENT PENDING protection device(A) <br /> UNIRAC MFR DDDYYP COWOIM <br /> C U S IDENTIFICATION OF COMPONENTS AND MATERIALS <br /> UWACMR <br /> End Clam M101XX Rev.H <br /> 266909 Extruded Aluminum:6005A-T61,6351-T5,6061-T6,6005-T5, <br /> DRAWING BY: <br /> SYSTEM FIRE CUSS RATING:SEE INSTALUITION INSTRUCTIONS FOR INSTALLATION REQUIREMENTS TO ACHIEVE A 6105-T5 <br /> SPECIFIED SYSTEM FIRE CLASS RATING WRH THIS PRODUCT. Clwlmgiis wnat DESIGN LOAD HATING:SEE INSTALLATION INSTRUCTIONS FOR LOADS AND MODULES QUALIFIED FOR USE WITH THIS End Clam <br /> ON ASSembl MSOOXX Rev. C,(M50060—M50071) <br /> PRODUCT. Y Y.......................: <br /> Extruded Aluminum:6005A-T61,6351-T5,6061-T6,6005-T5, PLOT DATE: <br /> 6105-T5 <br /> Nameplate adhesive label material approval information: <br /> Bonding Mid Clamp.........................: M6065X,Rev A and M6065X,Rev F <br /> Markings applied via permanent stamping to bay. 300 Series Stainless Steel PROJECT NUMBER: <br /> SHEET NAME: <br /> SPEC SHEET <br /> DQD 507.10 Rev 2022-08-05 ©2022 CSA Group. All rights reserved. DQD 507.10 Rev 2022-08-05 ©2022 CSA Group. All rights reserved. REVISION: PAGE NUMBER: <br /> -___ SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.