Laserfiche WebLink
Ner- <br /> BLUE RAC <br /> 1403 N.Research Way <br /> FLASHLOCTM DUO U N I RAC FLASHLOCTM DUO097 <br /> U N I RAC 800.37T8480 <br /> 800.377.4480 <br /> W W W.BLU ERAVENSOLAR.COM <br /> THE MOST VERSATILE DIRECT TO DECK ATTACHMENT BETTER SOLAR STARTS HERE INSTALLATION GUIDE BETTER SOLAR STARTS HERE CONFIDENTIAL-THE INFORMATION <br /> HEREIN CONTAINED SHALL NOT BE <br /> USED FOR THE BENEFIT OF ANYONE <br /> PRE-INSTALL: CLEAN SURFACE AND MARK LOCATION EXCEPT BLUE RAVEN SOLAR NOR <br /> FLASHLOCTM DUO is the most versatile direct to deck and rafter attachment for composition shingle and rolled SHALL IT BE DISCLOSED IN WHOLE OR <br /> Ensure existing roof structure is capable of supporting the roof attachment point loads IN PART TO OTHERS OUTSIDE <br /> comp roofs.The all-in-one mount installs fast— no kneeling on hot roofs to install flashing, no prying or cutting stated in the racking system engineering specifications.Clean roof surface of dirt, debris, RECIPIENTS ORGANIZATION,EXCEPT <br /> IN CONNECTION WITH THE SALE AND <br /> shingles, no pullingnails. Simply drive the required number of screws to secure the mount and inject sealant Snout and ice. USE OF THE HOUTTHEWRITT N EQUIPMENT, <br /> b p y Q � WITHOUT THE WRITTEN PERMISSION <br /> into the base. FLASHLOC's patented TRIPLE SEAL technology preserves the roof and protects the penetration Snap chalk lines for attachment rows. On shingle roofs,snap lines 1/4" below upslope edge OF BLUE RAVEN SOLAR LLC. <br /> of shingle coarse. This line will be used to align the upper edge of the mount. <br /> with a permanent pressure seal.Kitted with two rafter screws,sealant and hardware for maximum convenience NOTE:Space mounts per racking system installation specifications. <br /> (deck screws sold separately). Don't just divert water,LOC it out! NABCEP <br /> STEP ONE: SECURE CERTIFIED <br /> ATTACHING TO A RAFTER: Place FLASHLOC DUO over rafter location with sealant port on PV INSTALLATION <br /> up-slope side and align upper edge of mount with horizontal chalk line. Secure mount with the PROFESSIONAL <br /> two (2) provided rafter screws.BACKFILL ALL PILOT HOLES WITH SEALANT. Scott Gurney <br /> ATTACHING TO SHEATHING: Place FLASHLOC DUO over desired location with sealant port on #PV-011719-015866 <br /> 25 up-slope side and align upper edge of mount with horizontal chalk line. Secure mount with the CONTRACTOR: <br /> YE <br /> AH <br /> two (2) provided rafter screws. Next,secure mount with four(4)deck screws by drilling BRS FIELD OPS <br /> �f through the FLASHLOC DUO deck mount hole locations.Unirac recommends using a drill as 385-498-6700 <br /> opposed to an impact gun to prevent over-tightening or stripping roof sheathing. <br /> IMPORTANT:SECURELY ATTACH MOUNT BUT DO NOT OVERTIGHTEN SCREWS. <br /> WARRANTY <br /> STEP TWO: SEAL <br /> Insert tip of UNIRAC approved sealant into port and inject until sealant exits vent. Follow <br /> sealant manufacturer's instructions. Follow sealant manufacturer's cold weather application <br /> guidelines,if applicable. <br /> NOTE:When FLASHLOC DUO is installed over gap between shingle tabs or vertical joints,fill gap/joint with <br /> y rj sealant between mount and upslope edge of shingle course. <br /> CUT SHINGLES AS REQUIRED:DO NOT INSTALL THE FLASHLOC SLIDER ACCROSS THICKNESS <br /> VARIATIONS GREATER THAN 1/8"SUCH AS THOSE FOUND IN HIGH DEFINITION SHINGLES. <br /> NOTE: If an exploratory hole falls outside of the area covered by the sealant,flash hole accordingly. <br /> NOTE: Read and comply with the Flashloc Duo Design&Engineering Guide prior to design and <br /> installation of the system. <br /> Cut Away View cut Away View USE ONLY UNIRAC APPROVED SEALANTS.PLEASE CONTACT UNIRAC FOR FULL LIST OF COMPATIBLE <br /> PROTECT THE ROOF LOC OUT WATER HIGH-SPEED INSTALL z SEALANTS. <br /> Install a high-strength waterproof attachment With an outer shield U contour-conforming gasket Simply drive the required number of screws and inject Continue array installation.Refer to SOLARMOUNT or NXT HORIZON Installation Guide for the remaining <br /> without lifting,prying or damaging shingles. ©and pressurized sealant chamber©the Triple Seal sealant into the portU to create a permanent pressure <br /> seal. system installation. DRAWING BY: <br /> technology delivers a 100/o waterproof connection. Y <br /> APRIL2021_FLASHLOCDUO_V1 <br /> PLOT DATE: <br /> FASTER INSTALLATION . 25 -YEAR WARRANTY. FASTER INSTALLATION . 25 -YEAR WARRANTY. <br /> PROJECT NUMBER: <br /> —� '• QUESTIONS 1 ' CUSTOMER SERVICE VISIT UNIRAC.COM1 ' 15) 248-2702 FOR QUESTIONS 1 ' CUSTOMER SERVICE VISIT UNIRAC.COM1 ' I 48 I <br /> SHEET NAME: <br /> SPEC SHEET <br /> REVISION: PAGE NUMBER: <br /> ---- SS <br />