6708 CADY RD 2025-03-31
>
Address Records
>
CADY RD
>
6708
>
6708 CADY RD 2025-03-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2025 7:46:21 AM
Creation date
2/10/2025 10:18:47 AM
Metadata
Fields
Template:
Address Document
Street Name
CADY RD
Street Number
6708
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
mThe Laundry unit shown was not part of <br /> m" Site obscuring fence to be the approved plan. HE decison <br /> installed prior to operation Summary of Record#4 notes laundry to n { n <br /> and complaint with EMC be done in existing buildings. PCII It2CtUr@ <br /> N 19.40 PROPERTY LINE DIMENSION,TYP is,__ _ __ _ __ _ _ __ __ Site Plan <br /> C. C �, 315.7T -- -- -- -- --� <br /> �! IT! NEW 6'S1GNr-OBSCURING CEDAR FENCE,TYR E Scale:1"=20' <br /> Co D I <br /> 1. The site currently has five church buildings and surface parking.Improvements shown based on publicly available information. <br /> ry 0 '� I 0t 7YP EDGE OF EXISTING ASPHALT EXISTING ILDINGS SHOWN LIGHT,TYP. I Deemed accurate but not guaranteed.Verify existing conditions as needed. Locate all utilities prior to any site disturbance. <br /> co < NEW 6'SIGHT-OBSCURING CEDAR FENCE I 2. Lot size:1.67 acres. <br /> II 3. Zoning:R-2. <br /> w d 3 IP PROVIDE UNDERGROUND I1OV POWER <br /> N to :: /`TO EACH PALLET 5HELiER 4. Snohomish County Assessor Parcel Number:00400000002000. <br /> > Z A y / PROPOSED 100 5F PALLET 5NEL TER TYP. 5. Legal description: CADYS ADD TO BEVERLY HILLD BLK 000 D-00-LOTS 20&21&24&25 LESS RD R/W TO <br /> D 0 (D 9'HIGH GABLE ROOF RIDGE WHEELCHAIR AC E5515LE I CITY OF EVE PER SWC REC AF 200011070038(EXEMPT PER ST OF WA REG#02524-001) <br /> 40'55HL ADA-COMPL N UNIT <br /> C,m _ - LAUNDRY UNIT(ADA-COMP ANTI I <br /> f qi-0„ EXISTING CHURCH BUILDING 6. Property Address:6708 Cady Road,Everett,Washington 98201. <br /> ADA-COMPLIANT FROST-PR OF <br /> UNITC HC UNCHANGED <br /> UNIT D NOSE BIB AND DRINKING F NTAIN I 7. Owner:Faith Lutheran Church. <br /> UNITB <br /> U N IT A 42"GATE <br /> I umi TYPICAL 54EL TER SPACING ADA ASPHAL DINGS ADA NARDW RE 8. Existing lot coverage:13,950 SF(19.2%). Proposed lot coverage:15,182 SF(20.9%). <br /> h ASP T G U T H 1 <br /> UNITE U HALT 5'WIDE ADA WALKWAY,TYP CA ASPHALT RA 5 5'W I 9. Proposed new surface areas:3,219 SF gravel,318 SF asphalt ADA access,1,124 SF shelter roof area. <br /> © Im 10.Proposed improvements to comply with the applicable provisions of Everett Municipal Code,Section 19.08.200. <br /> NINI1.Verify existing ADA-compliant access from parking to ramp for ADA-compliant shelter. <br /> . _,. 12.ADA-compliant shelter and bathroom access includes 5'wide asphalt walkway and ramp,maximum slope 1:12,maximum rise 6". No railings required. <br /> x <br /> DADA ASPH. T I 13.The site is generally flat with no changes proposed or required to the existing topography. <br /> EXISTING 3'FEN�E J - L A+Q I IDE 14.No trees shall be removed as part of the proposed work effort. PO BON 141 <br /> HATCHING INDICATES AAREA OF NEW GRAVEL <br /> 'I I �'(4,675 SF) FD Kno Box 15.Electrical service to each shelter provided from existing church building.The electrical permit application is a separate submittal. E D M O N 0 S, W A S H I N C T 0 N 9 8 0 2 0 <br /> FROST-PROOF NOSE BIB J / NC 16.New restrooms to be connected to existing on-site water and sewer lines. Verify sizes and locations of new and existing services. (2 0 6)920.3554 P <br /> STANDARD 24fALL BATHROOM UNIT Y FROM FENCE J =�.1 `DA ASPHALT© EXISTING I 17.About 80 cubic yards of grading proposed to remove 6"of sod and provide 6"of gravel in area shown. W W W.P W f A R C H I T E C T O R E.C 0 N <br /> WHEELCHAIR ACCE55151.E 2-877AALL _ RAMP 5'WIDE, SIDEWALK I 18.See also separate civil engineering drawings. <br /> ADA-COMPLIANT BATHROOM UNIT Y FROM FENCE - 11,Pallet shelters provided,assembled,and installed by others. Contractor to coordinate assembly and installation with Contractor's scope of work. <br /> L - - EXI5 NG CHURCH ILDING <br /> 40'BSBL UNCHANGED A mard`m' <br /> f Permit#: PW2307-018 Or American Institute of Architects <br /> UNITS SHALL HAVE I Site Address: 6708 Cady RD <br /> UNIT NUMBERS Owner: Faith Lutheran Church Everett PROJECI N A W E: <br /> PROMINENTLY Application Date: 07/31/2023 <br /> DISPLAYED FOR Description: Site Work to Place 8 Temporary Pallet Shelters Faith Family Village <br /> I EMERGENCY SERVICES Applicant shall insure 40 parking spaces are made <br /> Q available as descried in application and noted in decision Temporary Shelter <br /> Review Status: Approved as Noted <br /> ul prior to operation Review Date: 08/18/2023 <br /> - - -- - -- 5 EXISTING STALLS _ C7o0(�a,Jy pOa,J <br /> NEW b'SIGHT-OBSCURING CEDAR FENCE, V 1 0 Cady Road <br /> -__ - LABELE "S.HELTERRE5IDENTSONLYAFTER .00 PhI" u <br /> z APPROVED Everett WA 98201 <br /> Every 90 days each of the pallet shelters shall be N PUBLIC WORKS DEPARTMENT <br /> emptied of all contents and inspected to ensure EXISTING PAVED PARKING xl <br /> UNCHANGED "� BY:Thad Newport <br /> structural stability and safety.A site inspection will be I <br /> conducted b the Everett Fire Dept.on an annual I ` DATE:F EVE2a23 <br /> y p I - 0"\� CITY OF EVERETT REVIEWED FOR PERMIT <br /> basis.EFD-KB • Vim► <br /> PR0JECT NUMBER: <br /> 01.22004 <br /> APPROVED <br /> \ Office of Community,Planning&Economic Development BATE <br /> Im T�1 PLANNING DEPARTMENT <br /> NAME: Dennis Osborn June 28,2023 <br /> I U\ : <br /> I - EXISTING CHURCH BUILDING �•I DATE 08/18/2023 <br /> UNGHANCsED STAMP: <br /> • I <br /> I <br /> I I <br /> gTA REGISTERED <br /> ARCHITECT <br /> • I <br /> Prior to operation and per Condition 2 of the HE decision, provide the City a I P IL W' <br /> revised Management Plan that addresses all of the requirements noted in the rot F WASHI GTON <br /> HE decision. ml <br /> N <br /> N <br /> u ATLANTA POST CAF5"BLACK RESIN P05T CAP,SKU 55556E <br /> IC,o 2x4 CEDAR CAP,SET HORIZONTALLY BETWEEN POSTS, <br /> ul`z� w ('ABOVE LOWEST GRADE BETWEEN POSTS NOTE: <br /> I u SECURE WITH GALVANIZED NAILS <br /> The information contained herein is intended to <br /> EXISTING PAVED PARKING P.T.2x4 TOP RAIL Ix4 CEDAR RAIL be used in conjunction with shop drawings, <br /> UNCHANGED NI (SECURE WITH SIMPSON FSR24Z) SECURE WITH GALVANIZED NAIL5 <br /> w approved submittals,diagrams,specifications, <br /> and any other documents as required as a guide <br /> F.T.bxb NOMINAL POST V O.C, for construction in a manner consistent with <br /> applicable codes and generally-accepted <br /> 0 %'k5'/z"CEDAR FENCE BOARDS,'/a"GAP BETWEEN BOARDS industry standards of construction,Anyconflicts <br /> SECURE WITH GALVANIZED NAIL5 within and between these documents and such <br /> ' codes and standards shall be brought to the <br /> PROPERTY LINE <br /> / r attention of the Architect prior to construcfion for <br /> b P.T.24 BOTTOM R41L B"ABOVE GRADE clarification as needed. <br /> EXISTING /�VEHICLE (SECURE WITH SIMP'SON F5R24Zl <br /> I"CLEARANCE AT BOTTOM OFFENCE BOARDS <br /> ACCESS _ <br /> 17NGN ED -- -- REVISION$: <br /> I"•' //. I6"DIA.x 30"DEEP POST POLE FILLED <br /> WITH MIN 1000 PSI CONCRETE <br /> -- - - - - - - - - - - - - - - - - - - <br /> Madison Street , • "' ' <br /> Fence Section <br /> Scale:1/2"=V-0" <br /> 1.Verify property line locations and the presence of any underground utilities. <br /> 2. Treat all cut ends of treated lumber with preservative. SHEET T 1 T E E: <br /> 3. Fence boards to be facing out with respect to the Pallet shelters'location. Site Plan <br /> 4. Verify method of attachment of fence to existing buildings with the Architect. <br /> SHEET NUMBER. <br /> A1 . 01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.