Laserfiche WebLink
BASE SLIDING <br /> Sliding at the base is checked at the block to leveling pad interface between the base block and the leveling <br /> pad. Sliding is also checked between the leveling pad and the foundation soils. <br /> Forces Resisting sliding =W1 <br /> 514 N =514ppf <br /> Resisting force at pad = (N "0.7 *tan(slope) + intercept x L) <br /> 514 x 0.7 x tan(40.0) + 0.0 + 0 Rf=360 <br /> Driving force is the horizontal component of <br /> Pah <br /> 151 Df=151 <br /> FSsl = (Rf/ Df) and (Rf1 / Do FSsl=1.58/4.77 <br /> Note: Calculations and quantities are for PRELIMINARY ANALYTICAL USE ONLY and MUST NOT be used for final <br /> n or construction without the independent review, verification, and approval by a qualified professional engineer. <br /> Cornerstone Analysis and Design 5.1.21009.30 7 <br />