Laserfiche WebLink
POE Fuel Float Piling <br /> SMS <br /> 3/13/2023 <br /> Consulting Engineers <br /> POE Float Guide Piling <br /> Rupture in Net Section <br /> U 1 Shear Lag Factor <br /> Ar, 27.49 in Net Area <br /> Ae=An*U 27.49 in Effective Net Area <br /> Pnr= F„*Ae 1924.23 kip Tensile Strength for Rupture <br /> (Ptr*Pnr 1443.17 Factored Strength for Rupture <br /> (PtPn = min{cpty*Pny,(Ptr*Pnr} 1443.17 kip Factored Tensile Strength <br /> Axial-Flexure Interaction (AISC Sect. H) <br /> When P„/cpPr,>=0.2 <br /> Pu/(PPn+8/9*(Mu/(PMn) <= 1.0 <br /> When P„/(pPn< 0.2 <br /> Pu/(2(PPn) + Mu/(PMn<= 1.0 <br /> C:\Users\sstory\Desktop\2017.04.18 Pile Strength Check-Pile Row A.S.xls Page 3 <br />