Laserfiche WebLink
XFMR 'TBF' <br />GRINDER PUMP CONTROL <br />PANEL <br />LEAK DETECTION <br />PANEL <br />WALL MOUNTED <br />DATA RACK <br />EF-01 <br />120V/10 <br />2HP DUPLEX <br />GRINDER PUMP <br />HIGH WATER ALARM <br />LIGHT, CONNECT TO <br />PUMP CONTROL PANEL <br />'GPC'. VERIFY EXACT <br />LOCATION PRIOR TO <br />ROUGH -IN <br />WH (3) 3.5KW <br />120V/10 <br />HOLIDAY LIGHT <br />OUTLET <br />FIRE ALARM <br />INTERFACE <br />PANEL <br />FUEL DISPENSOR <br />CONTROL PANEL <br />ROLL -UP DOOR <br />1 /2HP, 115V,10. VERIFY <br />EXACT LOCATION PRIOR TO <br />ROUGH -IN, TYP OF 2 <br />KEYED SWITCH FOR ROLL -UP <br />DOOR, VERIFY EXACT <br />LOCATION PRIOR TO <br />ROUGH -IN, TYP OF 2 <br />EWH-01 <br />208V/10 <br />EPO SW. <br />(EFSO-3) <br />ENLARGED ELECTRICAL PLAN - VENDING <br />4' 0 4' 8' <br />2' 6' <br />SCALE: 1 /4"=1 ' N <br />GENERAL NOTES: <br />1. ELEVATE TRANSFORMER `TBF' 12 INCHES ABOVE THE DECK OF THE FLOATING DOCK <br />USING AN GALVANIZED STEEL STAND. STAND SHALL BE RATED FOR THE SPECIFIED <br />TRANSFORMER AND CERTIFIED BY THE MANUFACTURER OR STRUCTURAL ENGINEER. <br />COORDINATE ANCHORING AND SUPPORT REQUIREMENTS WITH FLOAT MANUFACTURER. <br />I <br />w <br />I <br />U <br />0 <br />0 <br />a� <br />w <br />C <br />.L <br />C <br />U <br />N w <br />O <br />w w <br />4_;r- <br />0 0 <br />>, O <br />O - <br />w j <br />0 <br />Q <br />e ! HRRBOR POWER <br />0 <br />0 E N 6 1 N E E R S, I N C. <br />llillillilillill Jill 11111111111 111111111111 llill iiiiiiiiiij Jill lIllJlljl11llJl„ <br />E LL- PM: ED DAVID, PE TEL: 206.855.4600 <br />w <br />O <br />N <br />I o <br />CD CDor ofN I <br />CD N <br />N N <br />CD <br />cr j <br />vERETTE <br />� U <br />o P.O. BOX 538 <br />EVERETT, WA 98206 <br />o / (425) 259-3164 <br />1601 5th Avenue, Suite 1300 <br />Seattle, Washington 98101 <br />(206) 382-0600 Fax (206) 382-0500 <br />PROJECT NO. 1600120 <br />a <br />1 <br />1 <br />u <br />S15 <br />S15A <br />600 <br />0 <br />an <br />4 <br />4 <br />❑F <br />S1 <br />EPO SW. <br />MATCHLINE - SEE SHEET E4.1 (EFSl <br />O O <br />VENDING SHELTER; LCEN 4 LCEN 4 <br />-SEE ENLARGED Q 0 EMERGENCY <br />PLAN, THIS SHEET CALL BOX <br />LCEW o <br />02a LCEW a <br />FUEL DISP. #6 (GAS) 4 1 1 4 2C-01 <br />LWE +44 ATTENDANT a LWE POWER CONNECTION VIA <br />��� r� HP-01 PER MACHANICAL <br />HP-01 ❑ O 0 i I <br />208V/10 <br />LC W 2a LCEW 2a <br />(LOCATED IN F -1 L J <br />ATTIC SPACE <br />4 I 1 10/12 4 <br />BFA I I <br />LWE �_� E -0 <br />LWE <br />LCEWO2a LCEW�a' <br />FUEL DISP. #5 (GAS) <br />7=6 +10 4 <br />FUEL DISP. #4 (GAS) <br />FUEL DISP. #3 (DIESEL) <br />FUEL DISP. #2 (DIESEL) <br />ATTENDANT <br />BUILDING; SEE <br />ENLARGED PLAN, <br />THIS SHEET <br />DISP. #1 (DIESEL) <br />ELECTRICAL PLAN - FUEL DOCK SOUTH <br />�06/20/2023 <br />EJD <br />ADDENDUM #1 <br />10 <br />05/19/2023 <br />EJD <br />ISSUED FOR BID <br />A <br />04/11/2023 <br />EJD <br />ISSUED FOR PERMIT REVIEW <br />NO. <br />DATE <br />BY <br />REVISION <br />NO. <br />DATE <br />BY <br />REVISION <br />05/19/2023 <br />PROJECT ENGINEER <br />E. DAVID <br />DESIGNED BY: <br />E. DAVID <br />D RAW N BY: <br />K. DAVID <br />SCALE: <br />1" = 20' <br />DATE: <br />05/19/2023 <br />CHECKED BY: <br />E. DAVID <br />HOLIDAY LIGHT <br />LCENO4 LCEN O4 OUTLET <br />DATA J-BOX; <br />EF/ERV-01 0 24%1Il x4"D <br />WITH SCREW <br />211l COVER <br />ENLARGED ELECTRICAL PLAN - ATTENDANT BUILDING <br />LEGEND <br />w <br />X <br />YZ <br />IX <br />POWER PEDESTAL <br />V ; <br />V = VOLTAGE (WHEN USED) <br />` <br />W = SLIP NUMBER(S) SERVED <br />`. <br />X = 30 = 30A,120V OUTLET <br />X = 50 = 50A,120/240V OUTLET <br />X = 100 = 100A,120/240V OUTLET <br />Y = UNIT SUBSTATION <br />Z = CIRCUIT NUMBER <br />APPROXIMATE PEDESTAL PLACEMENT LOCATION <br />NOTE: 'X' DESIGNATES OUTLET PER SLIP. (i.e. 30/50) <br />INDICATES MULTIPLE OUTLETS PER SLIP. <br />❑ <br />JUNCTION BOX <br />- IN FLOAT; <br />UL LISTED <br />MINIMUM 30"x17"x18"D LION. <br />(P=POWER/C=COMMUNICATIONS) <br />or <br />POLE MOUNTED <br />LUMINAIRE; <br />SEE LUMINAIRE SCHED. SHT. Ell <br />0 <br />LUMINAIRE; SEE <br />LUMINAIRE <br />SCHEDULE <br />❑F FIRE PEDESTAL <br />- - - ELECTRICAL CHASES - INSIDE FLOAT (SEE DETAILS) <br />P PORTABLE POWER CABLE - NOTE: CABLES NOT ALWAYS SHOWN. <br />SEE SINGLE LINE WIRING DIAGRAM FOR CONNECTIONS. <br />- - - EXISTING RACEWAY OR CHASES <br />PORT OF EVERETT <br />CENTRAL MARINA FUEL DOCK <br />ELECTRICAL PLAN - FUEL DOCK <br />SOUTH <br />IF SHEET IS LESS THAN 22x34 <br />REDUCE SCALE ACCORDINGLY <br />DWG. NO. E4m2 <br />CIP NO. <br />2-0-073-01 <br />PROJECT <br />NO. MR-CM-2023-01 <br />SHEET No. 71 OF 88 <br />W <br />0 <br />