Simpson Strong-Tie"Wood Construction Connectors E=
<br /> Face-Mount Hangers — Solid Sawn Lumber (DF/SP)
<br /> The Joist Hanger Selector software enables you the most optimum product for your project.
<br /> The software takes into consideration all the characteristics seen in this catalog. Visit strongtie.com/jhs.
<br /> -These products are available with additional corrosion ®For stainless-steel Many of these products are approved for installation
<br /> protection.For more information,see p.14. fasteners,see p.21. MI with Strong-Drive®SD Connector screws.
<br /> N See pp.348-352 for more information.
<br /> i
<br /> CID
<br /> CI Dimensions m. Fasteners m. DF/SP Allowable Loads lb.
<br /> ( ) ( ) ( ) Installed
<br /> C Joist Model Min./ Code
<br /> Size No. Ga. Max. Uplift Floor Snow Roof Cost Index Ref.
<br /> = W H B Header Joist (160) (100) (115) (125) (ICI)
<br /> N Sawn Lumber Sizes
<br /> LU24 20 19/6 31/6 11/2 — (4)0.162 x 31/2 (2)0.148 x 11/2 240 555 630 655 Lowest
<br /> - 2X4 LUS24 18 1 9/6 31/6 13/4 — (4)0.148 x 3 (2)0.148 x 3 435 670 765 820 3%
<br /> N U24 16 1 9/6 31/6 11/2 — (4)0.162 x 31/2 (2)0.148 x 11/2 240 575 650 705 67%
<br /> HU26 14 1 9/6 3'Ar 21/4 — (4)0.162 x 31/2 (2)0.148 x 11/2 305 595 670 720 295%
<br /> p LUS24-2 18 3Y6 3Y6 2 — (4)0.162 x 31/2 (2)0.162 x 31/2 410 800 905 980 Lowest
<br /> N 2X4 U24-2 16 3Y6 3 2 — (4)0.162 x 31/2 (2)0.148 x 3 240 575 650 705 33%
<br /> HU24-2/HUC24-2 14 31/6 3 1A 6 21/2 — (4)0.162 x 31/2 (2)0.148 x 3 380 595 670 720 240%
<br /> ® LUS26 18 119/6 1 43/4 13/a 1 — (4)0.148 x 3 (4)0.148 x 3 1,165 865 1 990 1,060 Lowest
<br /> LU26 20 1 9/6 43/4 11/2 — (6)0.162 x 31/2 (4)0.148 x 11/2 540 835 950 1,030 6%
<br /> 2x6 U26 16 1 9/6 43/4 2 — (6)0.162 x 31/2 (4)0.148 x 11/2 535 865 980 1,055 43%
<br /> ® LUC26Z 18 1 9/6 43/4 13/4 — (6)0.162 x 31/2 (4)0.148 x 11/2 730 845 965 1,040 160%
<br /> HU26 14 1 9/6 3'Ar 21/4 — (4)0.162 x 31/2 (2)0.148 x 11/2 305 595 670 720 179%
<br /> HUS26 16 16/6 53/6 3 — (14)0.162 x 31/2 (6)0.162 x 31/2 1,320 2,735 3,095 3,230 276%
<br /> ® LUS26-2 18 3Y6 47/6 2 — (4)0.162 x 31/2 (4)0.162 x 31/2 1,060 1,030 1,170 1,265 Lowest
<br /> U26-2 16 3Y6 5 2 — (8)0.162 x 31/2 1 (4)0.148 x 3 535 1,150 1,305 1,410 65%
<br /> DBL HUS26-2 14 31/6 5-6 2 — (4)0.162 x 31/2 (4)0.162 x 31/2 1,165 1,055 1,195 1,290 172%
<br /> 2X6
<br /> HU26-2/HUC26-2 14 3Y6 41�6 21/2 Min. (8)0.162 x 31/2 (4)0.148 x 3 755 1,190 1,345 1,440 233%
<br /> �
<br /> 14 3Y6 415/16 21/2 Max. (12)0.162 x 31/2 (6)0.148 x 3 1,135 1,785 2,015 2,165 254%
<br /> LUS26-3 18 46/6 4Y6 2 (4)0.162 x 31/2 (4)0.162 x 31/2 1,060 1,030 1,170 1,265
<br /> TPL U26-3 16 46/6 41/4 2 (8)0.162 x 31/2 (4)0.148 x 3 535 1,150 1,305 1,410
<br /> 2x6 HU26-3 HUC26-3
<br /> 14 41Y6 4% 21/2 Min. (8)0.162 x 31/2 (4)0.148 x 3 755 1,190 1,345 1,440 IBC,FL,LA
<br /> � /
<br /> 14 411/16 4% 21/2 Max. (12)0.162 x 31/2 (6)0.148 x 3 1 1,135 1,785 1 2,015 2,165
<br /> ® LUS26 18 19/6 43/4 13/4 — (4)0.148 x 3 (4)0.148 x 3 1,165 865 990 1,060 Lowest
<br /> LU26 20 19/6 43/4 11/2 — (6)0.162 x 31/2 (4)0.148 x 11/2 540 835 950 1,030 6% 2!
<br /> z
<br /> ® LUS28 18 19/6 66/a 13/4 — (6)0.148 x 3 (4)0.148 x 3 1,165 1,100 1,260 1,350 23% a
<br /> 2
<br /> LU28 20 19/6 63/8 11/2 — (8)0.162 x 31/2 (6)0.148 x 11/2 850 1,110 1,180 1,180 39% ov
<br /> 2x8 U26 16 19/6 43/4 2 — (6)0.162 x 31/2 (4)0.148 x 11/2 535 865 980 1,055 43%
<br /> ® LUC26Z 18 1 9/6 43/4 13/4 — (6)0.162 x 31/2 (4)0.148 x 11/2 730 845 965 1,040 160% o
<br /> CE
<br /> HU28 14 19/6 51/4 21/4 — (6)0.162 x 31/2 (4)0.148 x 11/2 605 895 1,010 1,080 251%
<br /> HUS26 16 16/6 53/6 3 — (14)0.162 x 31/2 (6)0.162 x 31/2 1,320 2,735 3,095 3,230 276% o
<br /> W
<br /> HUS28 16 16/6 7 3 — (22)0.162 x 31/2 (8)0.162 x 31/2 1,760 4,095 4,095 4,095 409%
<br /> ® LUS26-2 18 3Y6 47/6 2 — (4)0.162 x 31/2 (4)0.162 x 31/2 1,060 1,030 1,170 1,265 Lowest N
<br /> 0
<br /> ® LUS28-2 18 3Y6 7 2 — (6)0.162 x 31/2 (4)0.162 x 31/2 1,060 1,315 1,490 1,610 8% o
<br /> DBL U26-2 16 31/6 5 2 — (8)0.162 x 31/2 (4)0.148 x 3 535 1,150 1,305 1,410 65% o
<br /> N
<br /> 2x8 HUS28-2 14 31/6 7Y16 2 — (6)0.162 x 31/2 (6)0.162 x 31/2 1,320 1,580 1,790 1,930 188% ti
<br /> U
<br /> HU28-2/HUC28-2 14 3Y6 6�6 21/2 Min. (10)0.162 x 31/2 (4)0.148 x 3 755 1,490 1,680 1,800 397%
<br /> ®
<br /> 14 3Y6 69/16 21/2 Max. (14)0.162 x 31/2 (6)0.148 x 3 1,135 2,085 2,350 2,530 418%
<br /> LUS28-3 18 4% 61/4 2 — (6)0.162 x 31/2 (4)0.162 x 31/2 1,060 1,315 1,490 1,610
<br /> TPL U26-3 16 4% 41/4 2 — (8)0.162 x 31/2 (4)0.148 x 3 535 1,150 1,305 1,410
<br /> 2X8 HU26-3/HUC26-3 14 41Y6 4% 21/2 Min. (8)0.162 x 31/2 (4)0.148 x 3 755 1,190 1,345 1,440
<br /> �
<br /> 14 411/16 4% 21/2 Max. (12)0.162 x 31/2 1 (6)0.148 x 3 1,135 1,785 2,015 2,165
<br /> QUAD HU28-4/HUC28-4 14 6Y6 7 21/2 Min. (10)0.162 x 31/2 (4)0.162 x 31/2 755 1,490 1,680 1,800
<br /> � —
<br /> 2X8 14 6Y6 7 21/2 Max. (14)0.162 x 31/2 1 (6)0.162 x 31/2 1,135 2,085 2,350 2,530
<br /> See footnotes on p.108. Codes:See p.11 for Code Reference Key Chart
<br /> 104
<br />
|