My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3200 CEDAR ST 2025-03-24
>
Address Records
>
CEDAR ST
>
3200
>
3200 CEDAR ST 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/18/2025 2:56:16 PM
Creation date
2/10/2025 11:37:36 AM
Metadata
Fields
Template:
Address Document
Street Name
CEDAR ST
Street Number
3200
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POWER ONE—LINE DIAGRAM ABBREVIATIONS <br /> EQUIPMENT PANEL OR ENCLOSURE AS LABELED Ulu l!1 A L <br /> POWER TRANSFORMER A AMMETER,AMPERE LCP LOCAL CONTROL PANEL <br /> T❑ POWER TRANSFORMER AD AUTODIALER LSIG LONG TIME,SHORT TIME, <br /> AF AMPERE FRAME RATING INSTANTANEOUS&GROUND(TO BE <br /> DISCONNECT,SIZE SHOWN.3-POLE NEMA 12 UNLESS 5 MOTOR,HORSE POWER AS SHOWN AFF ABOVE FINISHED FLOOR FURNISHED WITH THE BREAKER <br /> 30 Lf AIC AMPERE INTERRUPTING CAPACITY LV LOW VOLTAGE <br /> OTHERWISE SPECIFIED. <br /> AT AMPERE TRIP SETTING <br /> Z— <br /> 5 MANUAL MOTOR STARTER ATS AUTOMATIC TRANSFER SWITCH M <br /> M JC MOTOR OVERLOAD,SIZE PER LOAD AUX AUXILIARY <br /> AWG AMERICAN WIRE GAUGE MCC MOTOR CONTROL CENTER <br /> � DUPLEX RECEPTACLE MCP MAIN CONTROL PANEL <br /> �\ B MD MOMENTUM DYNAMICS <br /> ® __0 O— CIRCUIT BREAKER,THERMAL MAGNETIC TRIP, MFGR MANUFACTURER <br /> SPECIALTY RECEPTACLE,RATING AS SHOWN 400A 3-POLE,SIZE SHOWN BEB BATTERY ELECTRIC BUS MISC MISCELLANEOUS <br /> BKR BREAKER MTS MANUAL TRANSFER SWITCH <br /> ® CONNECTION POINT TO EQUIPMENT SPECIFIED,FURNISHED, MV MEDIUM VOLTAGE <br /> —O p— MAGNETIC CIRCUIT PROTECTOR <br /> AND INSTALLED UNDER OTHER SECTIONS. RACEWAY, 100/M C <br /> CONDUIT,AND CONDUCTORS PROVIDED BY ELECTRICAL. N <br /> C CONDUIT <br /> QJ JUNCTION BOX,SIZE PER CODE -(EO O->N DRAWOUT AIR CIRCUIT BREAKER,SIZE SHOWN CAT CATALOGUE N NEW,NEUTRAL <br /> 400A CB CIRCUIT BREAKER NC NORMALLY CLOSED <br /> CKT CIRCUIT NEC NFPA 70:NATIONAL ELECTRICAL CODE <br /> QM UTILITY REVENUE METER / COMM COMMUNICATIONS NEMA NATIONAL ELECTRICAL MANUFACTURERS <br /> SWITCH,3-POLE,SIZE SHOWN CT CURRENT TRANSFORMER ASSOCIATION <br /> ❑D LOW VOLTAGE MAGNETIC DIMMER 100A NIC NOT IN CONTRACT <br /> p NO NORMALLY OPEN <br /> lODDAT 5,2 MV DRAWOUT CIRCUIT BREAKER NTS NOTTO SCALE <br /> HANOHOLE SIZE PER CODE DEMO DEMOLITION <br /> HH <br /> DWG DRAWING O <br /> MECHANICAL KEY INTERLOCK FUSE,SIZE SHOWN,ONE PER PHASE E OL OVERLOAD <br /> 100A E,EX EXISTING P <br /> EF EXHAUSTFAN <br /> CONDUIT AND RACEWAY 10 POWER FACTOR CORRECTION CAPACITOR,KVAR ELEC ELECTRICAL PE PHOTO ELECTRIC RELAY <br /> INDICATED EMT ELECTRICAL METALLIC PFR POWER FAIL RELAY <br /> TUBING PLC PROGRAMMABLE LOGIC CONTROLLER <br /> (C000] CONDUITTAG,SEE SCHEDULE FOR DETAILS ES EMERGENCY STOP PNL PANEL <br /> CURRENT TRANSFORMER EV ELECTRIC VEHICLE PS PRESSURE SWITCH <br /> HOME RUN,DESTINATION LISTED IN CONDUIT SCHEDULE OR PSCP PUMP SEQUENCE CONTROL <br /> PANEL <br /> SHOW AS PANEL NAME(CIRCUIT NUMBER). F PT POTENTIAL TRANSFORMER <br /> W POTENTIAL TRANSFORMER FLA FULL LOAD AMP PVC POLYVINYL CHLORIDE <br /> EXPOSED CONDUIT AND OR WIRE AS SPECIFIED <br /> FT FEET <br /> FVNR FULL VOLTAGE NON-REVERSING S <br /> ----- CONCEALED OR BURIED CONDUIT AND WIRE AS SPECIFIED DELTA,TRANSFORMER CONNECTION STARTER <br /> SCR SHORT CIRCUIT RATING <br /> CONDUIT DOWN G SMC SOFT START MOTOR CONTROLLER <br /> SPUD SNOHOMISH PUBLIC UTILITY DISTRICT <br /> WYE,TRANSFORMER CONNECTION G GROUND SWBD SWITCHBOARD <br /> O CONDUITUP GFCI GROUND-FAULT CIRCUIT INTERRUPTER SWGR SWITCHGEAR <br /> GFPE GROUND FAULT PROCTECTION OF <br /> CONDUIT STUBBED AND CAPPED AS SHOWN EQUIPMENT T <br /> GRS GALVANIZED RIGID STEEL <br /> TSP TWISTED SHIELDED PAIR <br /> NOTE: ALL CONDUITS CONTAINING CONDUCTORS SHALL H TYP TYPICAL <br /> HAVE A GROUND SIZED PER CODE. ALL UNMARKED <br /> CONDUIT RUNS SHALL CONSIST OF 2#12 AND 1#12 HH H �J <br /> GROUND IN 3/4"CONDUIT. HP HOORSERSE POWER <br /> OWER <br /> HVAC HEATING VENTELATION AND AIR UH UNIT HEATER <br /> CONDITIONING UL UNDERWRITERS LABORATORIES <br /> GROUNDING HZ HERTZ UPS UNINTERRUPTIBLE POWER SUPPLY <br /> ( V <br /> W �' DRIVEN GROUND ROD,3/4"X 10'-0" ID FICATION V VOLT <br /> 1/0 INPUT/OUTPUT VAC VOLT ALTERNATING CURRENT <br /> DRIVEN GROUND ROD AND TEST WELL,3/4"X 10'-0"WITH 6" VDC VOLT DIRECT CURRENT <br /> DIAMETER HANDHOLE. J VFD VARIABLE FREQUENCY DRIVE <br /> d ! EXOTHERMIC WELDED GROUND CONNECTION JBOX JUNCTION BOX W -- <br /> c8 <br /> P K W WIRE <br /> WDOT WASHINGTON DEPARTMENT OF <br /> a KAIC KILOAMPERES INTERRUPTING CAPACITY TRANSPORTATION <br /> o n KCMIL THOUSAND CIRCULAR MILLS WP WEATHERPROOF <br /> KVA KILOVOLTAMPERE <br /> KVAR KILOVOLT AMPERES REACTIVE X <br /> LL KW KILOWATT <br /> KWH KILOWATT HOUR XFMR TRANSFORMER <br /> NOTE XP EXPLOSION-PROOF <br /> G THIS IS A STANDARD LEGEND SHEET.SOME SYMBOLS <br /> THAT APPEAR ON THIS SHEET MAY NOT APPEAR ON <br /> THE DRAWINGS. <br /> o � <br /> S $ <br /> F <br /> ing <br /> Bo �P K'S BEB INDUCTIVE CHARGER E—ELECTRICAL o,aw r ��� � EVERETT Got <br /> ' I� '" ` PUBLIC WORKS INSTALLATION <br /> s 1 NO. DATE APRVD REVISION nerewc.et ASSOCIATES INC. trect LEGEND AND SYMBOLS �wa2o. <br /> �3- PLANS ISSUED FOR 9 ,' r 320ett WA98201 <br /> 5 BID CONST RECORD "'��s� IZFLEM RN r9mtrkr FAxy*3W TEL(5031 E4+2490 Everett WA987m 11 <br /> _ yONdL T'`� �1 y_y �,r ,jG197fi0E www.elcon.com 425.25Z.8800 evererfwo.gov REGION-10 I STATE-WA I FEDERAL AI00-####### <br /> ACTION DATE I APRVD ACTION DATE APRVD ACTION DATE APRVD OlTdal <br /> Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always verify Scal <br />
The URL can be used to link to this page
Your browser does not support the video tag.