Laserfiche WebLink
GENERAL <br /> -... �. ..- YES NO <br /> Bathroom doors are easily and quickly openable from the outside when locked ❑ <br /> Carbon Monoxide alarms are installed as required in R315 on each level of the home. ❑ <br /> Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room,outside each separate <br /> sleeping area in the immediate vicinity of sleeping rooms(11314). ❑ <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all ❑ <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. ❑ <br /> R330.4 Operable parts of door handles, pulls, latches,locks and other devices installed in AFH shall be operable ❑ <br /> with one hand and shall not require tight grasping, pinching or twisting of the wrist(lever-type). <br /> Pocket doors shall have graspable hardware available when in the closed or open position. ❑ <br /> r <br /> R3118 Ramp ,.- w YES -_ NO <br /> Inside Ramp,. N/A r � <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope). (Exception R311.8.1 Not allowed in ❑ ❑ <br /> R330.9) <br /> R311.8.2 Landing Requirements:min. 3X3 foot landing at top/bottom,where doors open onto ramps,and where <br /> ramp changes directions. ❑ ❑ <br /> R330.9.1 Handrails required on both sides of ramp. ❑ ❑ <br /> Outside Ramp N/A❑ 3 _ M � YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope). (Exception R311.8.1 Not allowed inv OT ❑ <br /> R330.9) <br /> R311.8.2 Landing Requirements: min.3X3 foot landing at top/bottom,where doors open onto ramps,and where 1� ❑ <br /> ramp changes directions. <br /> R330.9.1 Handrails required on both sides of ramp. ❑ <br /> R312.1.1 Guards shall be located along open-sided walking surfaces,that are located more than 30 inches measured 4— ❑ <br /> vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br /> Guards below are depicted vertically as an example only. <br /> Handrail both sides <br /> Less than 4" 34"-38" <br /> Guard _- <br /> 36"min -- - <br /> l i <br /> 13'x3'min <br /> z� Tr7iL 1 l '° Sanding <br /> i I .. <br /> 3'x 3 min - - } ; <br /> rr- landing -L i <br /> 3 <br /> .minimum <br /> ' One unit vertical in twelve units horizontal - 3' - —-j <br /> Is an 8.3%slope all along surface of the ramp. minimum <br />`i <br /> f <br /> i <br /> i <br /> F <br /> i <br /> G <br /> 6 <br /> i <br /> i <br /> C <br /> b <br /> f; <br /> Implementation Date: 2021 February 01 <br /> 1 Updated: 2021 February <br />