4.5 Vent the Water Heater <br /> 4.51 Guidelines manufacturer for component assembly <br /> instructions. <br /> • If the vent system is to be enclosed, it is <br /> • Internal water heaters can be installed as suggested that the design of the enclosure <br /> direct vent or non-direct vent applications. shall permit inspection of the vent system. <br /> • When installed as Direct Vent, refer to the The design of such enclosure shall be <br /> "Direct Vent Approved Vent Manufactur- deemed acceptable by the installer or the <br /> ers and Products" section (within section local inspector. <br /> "4.5.4. 1. Direct Vent")for a complete list of • Any issues resulting from improper vent <br /> approved vent manufacturers and prod- installation will not be covered by warranty. <br /> ucts. <br /> • When installed as Non-Direct Vent(Room A WARN I N G <br /> Air), the vent must be Category IV, listed <br /> by a national recognized testing agency or • DO NOT use cellular core PVC/CPVC. <br /> schedule 40 PVC when accepted by local <br /> codes. DO NOT use Radel or galvanized material <br /> • Exhaust must be directly vented to the to vent this appliance. <br /> outside. Combustion air can be provided • DO NOT cover non-metallic vent pipe and <br /> from outside (Direct Vent) or from room air fittings with thermal insulation. <br /> (Non-Direct Vent). • DO NOT combine vent components from <br /> • If using room air(non-direct vent)for different manufacturers. <br /> combustion, ensure the required volume • DO NOT reduce the vent diameter. Vent <br /> of indoor air is available according to the diameter cannot be less than 2 in. (51 <br /> National Fuel Gas Code,ANSI Z223.1/ mm). <br /> NFPA 54. • DO NOT connect the venting system with <br /> • Avoid dips or sags in horizontal vent runs an existing vent or chimney. <br /> by installing supports per the vent manu- • Do not common vent with the vent pipe of <br /> facturer's instructions. any other manufacturer's water heater or <br /> • Support horizontal vent runs every 4 ft appliance. Rinnai water heaters can only <br /> (1.2 m) and all vertical vent runs every 6 ft be common vented with Schedule 40 PVC/ <br /> (1.83 m)or as per vent CPVC or with a Rinnai certified common <br /> manufacturer's instructions or local code vent system. <br /> requirements. <br /> • Venting should be as direct as possible <br /> with a minimum number of pipe fittings. <br /> • For manufactured vent systems, vent con- <br /> nections must be firmly pressed together <br /> so that the connections form an air tight <br /> seal. Follow the venting manufacturer's <br /> instructions. <br /> • Refer to the PVC/CPVC manufacturer for <br /> appropriate fittings, solvents or joining <br /> methods. <br /> • The vent piece connected to the water <br /> heater must be secured with 1 self-tapping <br /> screw. <br /> • Refer to the instructions of the vent system <br /> Rinnai Tankless Water Heater Installation and Operation Manual 26 <br />