My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
>
Address Records
>
SE EVERETT MALL WAY
>
909
>
CRUCIBLE BREWERY
>
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 7:30:51 AM
Creation date
2/10/2025 1:32:42 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
909
Tenant Name
CRUCIBLE BREWERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4.5 Vent the Water Heater <br /> 4.51 Guidelines manufacturer for component assembly <br /> instructions. <br /> • If the vent system is to be enclosed, it is <br /> • Internal water heaters can be installed as suggested that the design of the enclosure <br /> direct vent or non-direct vent applications. shall permit inspection of the vent system. <br /> • When installed as Direct Vent, refer to the The design of such enclosure shall be <br /> "Direct Vent Approved Vent Manufactur- deemed acceptable by the installer or the <br /> ers and Products" section (within section local inspector. <br /> "4.5.4. 1. Direct Vent")for a complete list of • Any issues resulting from improper vent <br /> approved vent manufacturers and prod- installation will not be covered by warranty. <br /> ucts. <br /> • When installed as Non-Direct Vent(Room A WARN I N G <br /> Air), the vent must be Category IV, listed <br /> by a national recognized testing agency or • DO NOT use cellular core PVC/CPVC. <br /> schedule 40 PVC when accepted by local <br /> codes. DO NOT use Radel or galvanized material <br /> • Exhaust must be directly vented to the to vent this appliance. <br /> outside. Combustion air can be provided • DO NOT cover non-metallic vent pipe and <br /> from outside (Direct Vent) or from room air fittings with thermal insulation. <br /> (Non-Direct Vent). • DO NOT combine vent components from <br /> • If using room air(non-direct vent)for different manufacturers. <br /> combustion, ensure the required volume • DO NOT reduce the vent diameter. Vent <br /> of indoor air is available according to the diameter cannot be less than 2 in. (51 <br /> National Fuel Gas Code,ANSI Z223.1/ mm). <br /> NFPA 54. • DO NOT connect the venting system with <br /> • Avoid dips or sags in horizontal vent runs an existing vent or chimney. <br /> by installing supports per the vent manu- • Do not common vent with the vent pipe of <br /> facturer's instructions. any other manufacturer's water heater or <br /> • Support horizontal vent runs every 4 ft appliance. Rinnai water heaters can only <br /> (1.2 m) and all vertical vent runs every 6 ft be common vented with Schedule 40 PVC/ <br /> (1.83 m)or as per vent CPVC or with a Rinnai certified common <br /> manufacturer's instructions or local code vent system. <br /> requirements. <br /> • Venting should be as direct as possible <br /> with a minimum number of pipe fittings. <br /> • For manufactured vent systems, vent con- <br /> nections must be firmly pressed together <br /> so that the connections form an air tight <br /> seal. Follow the venting manufacturer's <br /> instructions. <br /> • Refer to the PVC/CPVC manufacturer for <br /> appropriate fittings, solvents or joining <br /> methods. <br /> • The vent piece connected to the water <br /> heater must be secured with 1 self-tapping <br /> screw. <br /> • Refer to the instructions of the vent system <br /> Rinnai Tankless Water Heater Installation and Operation Manual 26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.