Common venting allows multiple Rinnai Tankless Water Heaters to share the same vent system. Rinnai <br /> water heaters can only be common vented with Schedule 40 PVC/CPVC or with the Rinnai certified <br /> common vent system. <br /> Figure 47: Example:Rinnai Common Venting Figure 48:Example: Schedule 40 PVC/CPVC <br /> Common Venting <br /> General Guidelines AWARNING <br /> When installing common vent, follow these guidelines: <br /> • Use only the materials listed in this manual • DO NOT slope the combustion air pipe <br /> for vent, air intake pipe, and fittings. Failure to toward unit. Failure to comply with this <br /> comply with this warning could result in prop- warning could result in property damage, <br /> erty damage, personal injury, or death. personal injury, or death. <br /> • When cutting vent components, ensure that • DO NOT apply PVC/CPVC glues, <br /> the cuts are straight. solvents, or cleaners to the tankless <br /> water heater's intake or exhaust gasket <br /> • Chamfer and deburr all edges before install- connections. Failure to correctly assem- <br /> ing the components. ble the components according to these <br /> • Vent joints must not leak. Confirm gas tight instructions may result in property dam- <br /> connections of every vent joint. age, personal injury, or death. <br /> • Before operating the water heater(s), ensure • DO NOT obstruct combustion air flow or <br /> vent system is clean and free of debris. exhaust gas flow in the venting system. <br /> • Vent system must be supported according to • DO NOT install the water heater in an <br /> the vent manufacture's installation instruc- area with negative air pressure. <br /> tions. • DO NOT combine the common vent <br /> • Venting should be as direct as possible with a system with existing vents, chimneys, <br /> minimum number of fittings. or vent pipes connected to other water <br /> • The common vent system must only be in- heaters, boilers or appliances. <br /> stalled by a trained and qualified professional. • DO NOT common vent different Rinnai <br /> models in a single common vent system. <br /> Common Vent Termination Clearances • DO NOT use cellular core PVC/CPVC, <br /> • Vent termination perANSI Z223.1/NFPA 54. Radel,ABS or galvanized materials. <br /> For clearances not specified in ANSI Z223.1/ • DO NOT combine vent components from <br /> NFPA 54, clearances are in accordance with different manufacturers. <br /> local installation codes and the requirements <br /> of the gas supplier. <br /> • Refer to section "4.5 Vent the Water Heater" <br /> for additional clearance requirements specific <br /> to the installation application. <br /> Rinnai Tankless Water Heater Installation and Operation Manual 48 <br />