Laserfiche WebLink
4.9 Connect Condensate Drain <br /> 4.9.1 Guidelines <br /> To prevent condensate damage, follow these • A condensate neutralizer kit is available <br /> guidelines: from Rinnai. The kit allows condensate to <br /> flow through neutralizing media that raises <br /> • Do not plumb the condensate drain with the pH of the condensate to a level that <br /> the pressure relief valve; both must be will help prevent corrosion of the drain and <br /> plumbed independently to drain. public sewer system. Refer to section "3.6 <br /> • All condensate must drain and be dis- Accessories"for more information. <br /> posed of according to local codes. • The condensate drain pipe should be as <br /> • Use only corrosion resistant materials for short as possible and have a downward <br /> the condensate drain lines such as PVC pitch. <br /> pipe or plastic hose. • The condensate trap will automatically <br /> • The condensate drain pipe (along its entire prime (self-prime)during operation of the <br /> length) must be at least the same diameter water heater as condensate forms. Con- <br /> as the drain line (1/2 in. MNPT). densate draining from the water heater <br /> • Condensation drain lines installed in areas indicates that the trap is full and that there <br /> that are subject to freezing temperatures is no blockage in the condensate drain. It <br /> should be wrapped with an approved sup- is not necessary to add water to the con- <br /> plemental heat source. Install per manu- densate trap. <br /> facturer's instructions. • DO NOT connect the condensate drain <br /> • Slope the condensate drain lines toward line with an air conditioning evaporator coil <br /> the inside floor drain or condensate pump. drain. <br /> • The end of the condensate drain pipe • Water heaters have an integrated <br /> should be open to the atmosphere. The condensate trap. DO NOT install <br /> end should not be under water or other an external condensate trap. <br /> substances. <br /> I Ed <br /> CORRECT NOT CORRECT <br /> Pipe open to Pipe submerged <br /> atmosphere in water <br /> Water Water Neutralizer <br /> Level Pipe open to <br /> Refer to neutralizer <br /> atmosphere Installation Manual <br /> and local codes for <br /> ALevel <br /> /__ neutralizer installation <br /> guidelines. <br /> Figure 59 <br /> • For external (outdoor) installations, to min- <br /> imize freezing of the condensate, run the <br /> condensate drain line through an interior <br /> wall or between insulation and an interior <br /> wall. Pipe open to <br /> • If a floor drain is not available or the drain atmosphere <br /> is above the level of the condensate drain, <br /> a condensate pump should be installed. JCondensate <br /> Figure 60 Pump <br /> Rinnai Tankless Water Heater Installation and Operation Manual 58 <br />