My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
>
Address Records
>
SE EVERETT MALL WAY
>
909
>
CRUCIBLE BREWERY
>
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 7:30:51 AM
Creation date
2/10/2025 1:32:42 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
909
Tenant Name
CRUCIBLE BREWERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
410.2 Gas Pipe Sizing Reference Tables <br /> The gas supply must be capable of handling the entire gas Table 25: Gas Pipe Sizing Calculation <br /> load required at the location. Gas line sizing is based on Worksheet <br /> gas type, the pressure drop in the system, the gas pressure Instructions: Enter values in empty boxes. <br /> supplied, and gas line type. For gas pipe sizing, refer to Rinnai Model Gas Input: <br /> the National Fuel Gas Code,ANSI Z223.1/NFPA 54, or the <br /> Natural Gas and Propane Installation Code, CSA B149.1 FA Btu/hr <br /> For some tables, you will need to determine the cubic Additional Appliance Total Gas Input: <br /> feet per hour of gas required by dividing the gas input by B Btu/hr <br /> the heating value of the gas (available from the local gas <br /> company). The gas input needs to include all gas products Heating Value of Gas: <br /> at the location and the maximum Btu usage at full load when C Btu/ft3 <br /> all gas products are in use. <br /> Cubic Feet Per Hour(CFH): <br /> Use the table for your gas type and pipe type to find the <br /> pipe size required. The pipe size must be able to provide the A+ B <br /> required cubic feet per hour of gas or the required Btu/hour. (CFH) = C <br /> The information below is provided as an example. The <br /> appropriate table from the applicable code must be used. (CFH) _ <br /> Answer: L(CFH) = ft3/hr <br /> Natural Gas <br /> Table 26: Pressure Drop 0.5 in. w.c. Table 27: Example <br /> Rinnai Model Gas Input: <br /> Information in table Schedule 40 Metallic Pipe <br /> obtained from NFPA 54, A Btu/hr <br /> ANSI Z223.1-2015. Inlet Pressure: Less than 2 psi <br /> Specific Gravity: 0.60 Additional Appliance Total Gas Input: <br /> Nominal Pipe Size (in.) B 1 05,000 1 Btu/hr <br /> 1/2 3/4 1 1 1 1/4 Heating Value of Gas: <br /> Length in ft(meters) Capacity in Cubic Feet of Gas per Hour C 1,000 1 Btu/ft3 <br /> 10 (3) 172 360 678 1,390 <br /> Cubic Feet Per Hour(CFH): <br /> 20 (6) 118 247 466 957 A + B <br /> 30 (9) 95 199 374 768 (CFH) = C <br /> 40 (12) 81 170 320 657 1 000+O5 DOO <br /> 50 (15) 72 151 284 583 (CFH) = 1,000 <br /> 60 (18) 65 137 257 528 Answer: <br /> 70 (21) 60 126 237 486 (CFH) _ ft3/hr <br /> 80 (24) 56 117 220 452 <br /> For this example, the pipe diameter <br /> 90 (27) 52 110 207 424 must be at least 3/4 in. pipe size and <br /> 100 (30) 50 104 195 400 10 ft (3 m) in length. <br /> Rinnai Tankless Water Heater Installation and Operation Manual 62 <br />
The URL can be used to link to this page
Your browser does not support the video tag.