My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
>
Address Records
>
SE EVERETT MALL WAY
>
909
>
CRUCIBLE BREWERY
>
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 7:30:51 AM
Creation date
2/10/2025 1:32:42 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
909
Tenant Name
CRUCIBLE BREWERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ffnuontrol Inlet Thermistor <br /> 7 e the Venturi motor is operating Check sensor wiring for damage. <br /> tly.*ce gas valve assembly. Measure resistance of sensor.* <br /> ea diagnostic code by resetting the Clean sensor of scale build-up. <br /> main power supply to the water heater. Replace sensor. <br /> tgoing Temperature �Gasave <br /> 7(psafety <br /> s too hot) <br /> shutdown because water heater Check flame rod and wire for damage. <br /> Confirm fan motor is functioning Check gas solenoid valve for open or <br /> correctly. short circuit.* <br /> Replace the gas valve assembly. Replace gas valve assembly. <br /> 7.Venturi Blockage Please call Rinnai technical <br /> First, follow the recommended solutions department <br /> for Diagnostic Code 10. <br /> If the Code 10 solutions do not correct High Exhaust Gas Temperature <br /> the problem, ensure the Venturi is not Ensure Heat Exchanger fins are clean <br /> blocked. and not blocked. <br /> Please call Rinnai technical department. Confirm inlet water temperature is not <br /> Electrical Grounding too high. <br /> Check all components for electrical Clear diagnostic code by resetting <br /> short. the main power supply to the water <br /> heater. <br /> Data Transfer Error <br /> Combustion Fan <br /> • If the PCB has been replaced, ensure <br /> the data transfer process has been Check the motor wire harness for <br /> completed. loose or damaged connections. <br /> Measure resistance of motor wire <br /> Condensate Pump (Accessory) harness.* <br /> Confirm wire connections and harness Ensure the combustion fan spins <br /> are good. freely. <br /> • Ensure condensate reservoir is empty Recirculation Low Flow <br /> and condensate pump is operating. Ensure bypass plug is removed and <br /> Out oin Thermistor bypass filter is installed. (COV Mode) <br /> Check sensor wiring for damage. Ensure both the inlet water filter and <br /> • Measure resistance of sensor.* bypass filter are clean and free of <br /> debris. <br /> • Clean sensor of scale build-up. Ensure Parameter setting are correctly <br /> Replace sensor. set for recirculation mode. <br /> Heat Exchanger Thermistor Ensure Pump supply voltage. <br /> Follow the steps above for Code 32 for Ensure air is removed from the <br /> troubleshooting. recirculation line. <br /> Exhaust Thermistor Water Flow Control <br /> • Check sensor wiring for damage. Measure resistance values of the <br /> Measure resistance of sensor.* water flow control.* <br /> Replace sensor. The water flow control valve has failed <br /> to close during the bath fill function. <br /> Freeze Protection Thermistor Immediately turn off the water and <br /> s above for Code 38 for discontinue the bath fill function. <br /> Follow the steps Contact a licensed professional to <br /> troubleshooting. service the appliance. <br /> * See "Electrical Diagnostics" on Technical Data PC Board <br /> Sheet located on inside front cover of water heater. Replace PC Board <br /> Rinnai Tankless Water Heater Installation and Operation Manual 78 <br />
The URL can be used to link to this page
Your browser does not support the video tag.