Laserfiche WebLink
2/27/24, 12:56 PM waenergycodes.com/print_project_summary_form.php?k=aWQ9MjQxMjMmZnZpPTE3JnJIc2VOPTE=&debug=1 <br /> MECHANICAL COMPLIANCE SUMMARY <br /> 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all Rl Administered by:©2024 NEEA,All rights reserved <br /> Project Title Narrative Coffee-2018 WSEC For Building Department Use: I Date: Feb 27,2024 <br /> Project Address 2927 Wetmore Ave <br /> Project&Applicant Everett,WA 98201 <br /> Information Applicant Name Isabella le Beau <br /> Applicant Phone 425-252-3114 <br /> Applicant Email Permits@essmwa.com <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> General Occupancy All Commercial General Building Use Type Dining,Restaurant Building Cond.Floor Area 2,250 <br /> New Building Alteration Project Cond.Floor Area 2,250 <br /> General Project Types Alteration or Addition Mechanical Scope Single Zone Systems&Equipment Floors Above Grade 1 <br /> Mechanical Scope Compliance Method Compliance Method 1-General <br /> Mechanical Project Description Install Mitsubishi Heat Pump Systems.Two separate 2.5 ton systems with air handlers. <br /> Economizer Equipment Efficiency <br /> DOAS Ventilation Higher Equipment <br /> Mechanical Project Type Mechanical Scope Exception(s) Compliance <br /> Compliance Applied? Provided? Efficiency Option Applied? Verification <br /> Scope and Method Alteration Single Zone Systems& Yes No NA COMPLIES <br /> Equipment <br /> Additional Efficiency <br /> Credits Included <br /> (AEC) <br /> Does building include <br /> occupancy classifications No Does project include DOAS equipment? No <br /> requiring DOAS? <br /> Based on project scope <br /> do TSPR requirements No Do all systems comply with Appendix D standard reference design or qualify for an exception to TSPR? No <br /> apply? <br /> Scope&Space Conditioning ALTERATION-SINGLE ZONE SYSTEMS&EQUIPMENT ff Compliance Verification COMPLIES <br /> Single Zone Air Systems Category-Heat pump,unitary,thru-wall,SDHV <br /> Air Systems Summary Information <br /> Quantity Supply Airflow Ventilation CFM Ventilation Energy Recovery <br /> System/Equip ID of Items Control Ventilation Standard (Total if Multiple Items) Air Source Paired with DOAS Ventilation energy recovery Efficiency(%) <br /> HP11 2 1 Variable air volume IMC Natural Ventilation <br /> Air Systems&Equipment-Cooling <br /> System/ Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance <br /> Equip ID Cooling System/Equip Type Specific Type per item(Btu/h) Multiplier Multiplier(FL&PL) Multiplier(AEC&Econo) Efficiency Units Load Efficiency Units Verification <br /> HPI Heat pump,air cooled Split system 1 30,000 1 0 1 19.1 SEER IEER COMPLIES <br /> Air Systems&Equipment-Heating <br /> System Heating System/Equip Type Specific Type Heat Pump Heating Capacity(Btu/h) Cooling Capacity(Btu/h) AEC Efficiency Proposed Heat Pump HPH Proposed Low OSA LTH Efficiency Compliance <br /> /Equip ID Multiplier Heating Efficiency Units Temp Efficiency Units Verification <br /> HP Heat pump,air cooled,heating Split system 34,000 30,000 1 10.8 HSPF COP COMPLIES <br /> Air Systems&Equipment Details <br /> System/Equip ID I Area(s)Served Location In Project Documents-Plan/Detail# <br /> https://www.waenergycodes.com/print_project_summary_form.php?k=aWQ9MjQxMjMmZnZpPTE3JnJIc2VOPTE=&debug=1 1/2 <br />