Laserfiche WebLink
Finalizing the Installation <br /> Horizontal Termination <br /> DuraVent manufactures a vent kit for horizontal that allows for terminating horizontally when installed in a <br /> masonry fireplace (not for use with ZC fireplaces). The DuraVent kit (46DVA-HCL33 and 46DVA HCL34) <br /> is approved for use with Travis Industries gas inserts. <br /> These kits can be purchased from your Travis Industries dealer. <br /> Application DuraVent Part# <br /> For inserts that use 3" exhaust and 3" intake 46DVA-HCL33 <br /> For inserts that use 4" exhaust and 3" intake 46DVA-HCL34 <br /> Refer to the kit manufacturer's instructions for details and requirements for installation. In addition to the <br /> manufacturer's requirements, the following requirements must be met: <br /> O <br /> O <br /> O Q <br /> • The termination center MUST be <br /> a minimum of 5' from the base of <br /> insert. r>_ 4° <br /> O <br /> • The termination center MUST Radius <br /> NOT be more than 8' from the 4" Min <br /> base of the insert. - Tl <br /> • The radius of any bends in the O <br /> flexible venting MUST NOT be O <br /> less than a 4" radius Q O <br /> • All portions of the venting MUST O Min. 5' <br /> have at least a 1/4" rise per 12" of 00 Max. 8' <br /> horizontal run OO <br /> 00 <br /> O <br /> O <br /> O <br /> O <br /> • O <br /> ®a ----- <br /> OOOOOO <br /> ©Travis Industries 4/26/2023- 1558 430 MF GSR2 <br />