My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 ROCKEFELLER AVE COURTHOUSE 2025-06-23
>
Address Records
>
ROCKEFELLER AVE
>
3000
>
COURTHOUSE
>
3000 ROCKEFELLER AVE COURTHOUSE 2025-06-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2025 8:43:27 AM
Creation date
2/13/2025 2:47:51 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3000
Tenant Name
COURTHOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAY 0 9 2023 <br />CITY OF EVERET I' <br />Permit Services <br />LIGHTING COMPLIANCE SUMMARY <br />2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: C2022 NEEA, All rights reserved <br />Project & Applicant <br />Information <br />Project Title <br />Snohomish County Courthouse: Renovation New courtroom - 2018 WSEC <br />For Building Department Use: I Date: Mar 04, 2022 <br />Project Address <br />3000 Rockefeller ave. <br />Everett, WA 98201 <br />Applicant Name <br />DAJUANE THOMAS <br />Applicant Phone <br />513-885-1486 <br />Applicant Email <br />dthomas@slamcoll.com <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsuppott@waenergycodes.wm <br />General Occupancy <br />General Building Use Type <br />Public Services, Courthouse <br />Building Cond. Floor Area <br />19,321 <br />General Project Types <br />Alteration <br />New Building or <br />Addition <br />Lighting Scope <br />g g P <br />Alteration <br />Lighting Scope <br />Interior Lighting <br />Project Cond. Floor Area <br />2,790 <br />Floors Above Grade <br />5 <br />Compliance Method <br />Not Selected <br />Lighting Project Description <br />New lighting fixtures and lighting control devices to serve the renovated spaces. <br />Lighting Compilance Scope <br />Protect Type <br />Interior / Exterior <br />Luminaire Replacement Scope <br />Compliance Method <br />LPA Calculation <br />Compliance Verification <br />(Interior Inelaaet both interior & parking <br />Adjustment <br />and Method <br />Altemtion <br />Interior Lighting <br />500/6 or more replaced <br />Space by space <br />No Calculation Adjustments allowed <br />COMPLIES <br />Additional Efficiency <br />Options Included <br />Project Title Snohomish County Courthouse: Renovation New courtroom - 2018 WSEC Date Mar 04, 2022 <br />Lighting Power Calculation ALTERATION - INTERIOR LIGHTING (50% or more replaced) Compliance Verification COMPLIES <br />Compliance Method Space by space LPA Calculation Adjustment I none <br />Interior Lighting Power Allowance - Space by Space <br />General Space Type <br />Specific Space Type <br />Ceiling <br />Height (Ft) <br />Gross Interior Area (SF) <br />LPA (Watts/SF) <br />Total Watts Allowed <br />(SF x LPA x 1) <br />Total Proposed Watts <br />(LPD + Display LPD) <br />Compliance Status <br />Conference/meeting/multipurpose <br />228 <br />0.97 <br />221 <br />Computer room/data center <br />24 <br />0.94 <br />23 <br />Condors <br />General <br />196 <br />0.41 <br />80 <br />Corridors <br />General <br />34 <br />0.41 <br />14 <br />Courtroom <br />General <br />1,321 <br />1.20 <br />1,585 <br />Locker room <br />35 <br />0.52 <br />18 <br />Office <br />Enclosed less than 250 sf <br />129 <br />0.74 <br />96 <br />Office <br />Enclosed> 250 sf <br />280 <br />0.66 <br />185 <br />Restroom <br />General <br />24 <br />0.63 <br />15 <br />Restroom <br />General <br />84 <br />0.63 <br />53 <br />Storage room <br />50-100 sf <br />58 <br />0.38 <br />22 <br />Proposed Total LPD <br />1767 <br />Totals 1 <br />2,312 <br />1,767 <br />COMPLIES <br />Proposed Lighting Power Density <br />Watts or <br />Total Watts <br />Fixture Type <br />Fixture ID <br />Quantity of <br />Wattage Limit <br />Total Linear <br />Watts per Linear <br />Proposed <br />Fixtures (#F) <br />per Fixture <br />Feet (LF) <br />Foot (WpLF) <br />(#F x WpF) or <br />(WPF) <br />(LF x WpLF) <br />Individual Fixtures <br />Direct / indirect pendant <br />L16A-16 <br />1 <br />116 <br />116 <br />Direct indirect pendant <br />L16A-12 <br />3 <br />87 <br />261 <br />
The URL can be used to link to this page
Your browser does not support the video tag.