Laserfiche WebLink
FO R T E MEMBER REPORT PASSED <br /> Mezzanine,J2 <br /> 1 piece(s) 11 7/8"TJI®360 @ 16"OC <br /> 0 0 <br /> I <br /> 4' 16 / <br /> 1 Q2 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual @ Location Allowed Result LDF Load:Combination(Pattern) System:Floor <br /> Member Reaction(Ibs) 697 @ 16'5 1/2" 1080(1.75") Passed(65%) 1.00 1.0 D+ 1.0 L(All Spans) Member Type:Joist <br /> Building Use:Residential <br /> Shear(Ibs) 697 @ 16'5 1/2" 1705 Passed(41%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2018 <br /> Moment(Ft-Ibs) 2802 @ 8'5" 6180 Passed(45%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.241 @ 8'5" 0.536 Passed(L/802) -- 1.0 D+1.0 L(All Spans) <br /> Total Load Defl.(in) 0.313 @ 8'5" 0.804 Passed(L/617) -- 1.0 D+1.0 L(All Spans) <br /> TJ-Pro'"Rating 46 45 Passed -- -- <br /> •Deflection criteria:LL(L/360)and TL(L/240). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> •A structural analysis of the deck has not been performed. <br /> •Deflection analysis is based on composite action with a single layer of 23/32"Weyerhaeuser Edgee'Panel(24"Span Rating)that is glued and nailed down. <br /> •Additional considerations for the TJ-Pro'"Rating include:None. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Total Accessories <br /> 1-Stud wall-HF 5.50" 4.00" 1.75" 168 561 729 1 1/2"Rim Board <br /> 2-Hanger on 11 7/8"HF beam 5.50" Hanger, 1.75"/-2 170 567 737 See note 1 <br /> •Rim Board is assumed to carry all loads applied directly above it,bypassing the member being designed. <br /> •At hanger supports,the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br /> •1 See Connector grid below for additional information and/or requirements. <br /> •2 Required Bearing Length/Required Bearing Length with Web Stiffeners <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 5'7"o/c <br /> Bottom Edge(Lu) 16'4"o/c <br /> •TJI joists are only analyzed using Maximum Allowable bracing solutions. <br /> •Maximum allowable bracing intervals based on applied load. <br /> Connector:Simpson Strong-Tie <br /> Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br /> 2-Face Mount Hanger IUS2.37/11.88 2.00" N/A 10-10dx1.5 2-Strong-Grip <br /> •Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br /> Dead Floor Live <br /> Vertical Load Location(Side) Spacing (0.90) (1.00) Comments <br /> 1-Uniform(PSF) 0 to 16'11" 16" 15.0 50.0 Dead+Live+ <br /> Partition <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by KGU <br /> ForteWEB Software Operator Job Notes <br /> 4/15/2021 12:25:35 AM UTC <br /> Kyle Umlauf <br /> Umlauf Engineers ForteWEB v3.1, Engine: V8.1.6.2, Data: V8.0.1.0 <br /> (509)551-6225 <br /> kyle@umlaufengineers.com Weyerhaeuser File Name: Copy of Zap Energy <br /> Page 3/4 <br />