My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2025-04-23
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 3:48:13 PM
Creation date
2/14/2025 8:21:33 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seismic Controls <br /> E-W at Floor Mezz <br /> Shearwall Schedule <br /> Total Shear Force 7.22 K,ASD DL Properties HF 8D <br /> Total Trib Width 55.75 FT SDS 0.962 SW-6 242 <br /> Floor Height 8 FT DL Factor 0.46532 SW-4 353 <br /> Total Force Check 7.22 K PASS SW-3 456 <br /> HD Dist From End 0 FT SW-2 595 <br /> 2SW-4 707 <br /> Wall Line N Line DL Properties 2SW-3 911 <br /> Trib To Wall Line 13.4375 FT DL Trib 10.835 FT 2SW-2 1190 <br /> Total Force 1.7402466 K Floor DL 15.0 PSF <br /> Total Wall Length 17.33 FT Wall DL 10.0 PSF <br /> Wall ID Height(ft) Length(ft) H:W Adjust Adjusted U-Shear Shear(Ib) SW- Gross DL Res(Ib) Force Net Force HD- <br /> Length(ft) (plf) Uplift(lb) Above(Ib) (Ib) <br /> N1 8 4 1 4 100 402 SW-6 803 226 578 N/A <br /> N2 8 8 1 8 100 803 SW-6 803 451 352 N/A <br /> N3 8 5.33 1 5.33 100 535 SW-6 803 301 503 N/A <br /> Wall Line C Line DL Properties <br /> Trib To Wall Line 27.875 FT DL Trib 8 FT <br /> Total Force 3.61 K Floor DL 15.0 PSF <br /> Total Wall Length 40.25 FT Wall DL 10.0 PSF <br /> Wall ID Height(ft) Length(ft) H:W Adjust Adjusted U-Shear Shear(Ib) SW- Gross DL Res(Ib) Force Net Force HD- <br /> Length(ft) (plf) Uplift(Ib) Above(Ib) (Ib) <br /> C1 8 9.75 1 9.75 90 874 SW-6 718 454 264 N/A <br /> C2 8 16.5 1 16.5 90 1480 SW-6 718 768 0 N/A <br /> C3 8 14 1 14 90 1256 SW-6 718 651 66 N/A <br /> Wall Line S Line DL Properties <br /> Trib To Wall Line 14.4375 FT DL Trib 8 FT <br /> Total Force 1.8697534 K Floor DL 15.0 PSF <br /> Total Wall Length 22 FT Wall DL 10.0 PSF <br /> Wall ID Height(ft) Length(ft) H:W Adjust Adjusted U-Shear Shear(Ib) SW- Gross DL Res(Ib) Force Net Force HD- <br /> Length(ft) (plf) Uplift(Ib) Above(Ib) (Ib) <br /> S1 8 10 1 10 85 850 SW-6 680 465 215 N/A <br /> S2 8 12 1 12 85 1020 SW-6 680 558 122 N/A <br /> Project Name:Zap Energy <br /> IIIUNILAUF ENGINEERS Project#:20-020 Date:4/2021 <br /> Subject:Shear Walls By:Name KGU <br />
The URL can be used to link to this page
Your browser does not support the video tag.