Laserfiche WebLink
System Specifications • CSFM:7165-0028:0243. <br /> • MEA: 128-07-E. <br /> SYSTEM CAPACITY • Fire Dept.of New York:COA#6212. <br /> • <br /> • Intelligent Signaling Line Circuits 1 City of Chicago. <br /> • <br /> • Intelligent detectors 159 ULC Listed:S527-11 <br /> • Addressable monitor/control modules 159 NOTE: For additional information on UL- and ULC-listed model <br /> Programmable internal hardware and output circuits 4 NFS-320C,see DN-60085. For information on NFS-320SYS,see <br /> • DN-60637. <br /> • Programmable software zones 99 <br /> • Special programming zones 14 Marine Applications: Marine approved systems must be config- <br /> • LCD annunciators per NFS-320/-320E 32 ured using components itemized in this document.(See Main Sys- <br /> temACS annunciators Components, in "Product Line Information.) Specific <br /> • per NFS-320/-320E <br /> 32 addresses x 64 points connections and requirements for those components are <br /> described in the installation document, PN 54756. When these <br /> SPECIFICATIONS requirements are followed,systems are approved by the following <br /> agencies: <br /> • Primary input power • US Coast Guard 161.002/50/0, 161.002/55/0 (Standard 46 <br /> -NFS-320:120 VAC,50/60 Hz,5.0 A. CFR and 161.002). <br /> -NFS-320E:220/240 VAC,50/60 Hz,2.5 A. • Lloyd's Register 1 1/60001 3(ENV 3 category). <br /> • Current draw(standby/alarm): • American Bureau of Shipping(ABS)Type Approval. <br /> -NFS-320(E) board: 0.250 A. Add 0.035 A for each NAC in NOTE:For information on marine applications,see DN-60688. <br /> use. <br /> -KDM-R2(Backlight on):0.100 A. STANDARDS <br /> • Total output 24 V power:6.0 A in alarm. The NFS-320 complies with the following UL Standards and NFPA <br /> NOTE: The power supply has a total of 6.0 A of available power. 72, International Building Code (IBC), and California Building <br /> This is shared by all internal circuits.See Installation Manual for a Code(CBC)Fire Alarm Systems requirements: <br /> complete current draw calculation sheet. • UL 864(Fire). <br /> • <br /> • Standard notification circuits(4): 1.5 A each. UL 1076(Burglary). <br /> • Resettable regulated 24V power:1.25 A. • UL 2572(Mass Notification Systems). (NFS-320 version 20 or <br /> • Two non-resettable regulated 24V power outputs: higher). <br /> • ULC-S527-11 Standard for the Installation of Fire Alarm Sys- <br /> -1.25 A. tems. <br /> -0.50 A. • LOCAL(Automatic, Manual,Waterflow and Sprinkler Supervi- <br /> • Non-resettable 5V power:0.15 A. sory). <br /> • Battery charger range: 18 AH-200 AH. Use separate cabinet • AUXILIARY(Automatic, Manual and Waterflow) (requires TM- <br /> for batteries over 26 AH. 4). <br /> • Float rate:27.6 V. • REMOTE STATION (Automatic, Manual,Waterflow and Sprin- <br /> kler Supervisory)(requires TM-4). <br /> CABINET SPECIFICATIONS • PROPRIETARY (Automatic, Manual, Waterflow and Sprinkler <br /> NFS-320 cabinet dimensions: Supervisory).Not applicable for FM. <br /> • Backbox: 18.12 in. (46.025 cm) width; 18.12 in. (46.025 cm) • CENTRAL STATION(Automatic,Manual,Waterflow and Sprin- <br /> kler 5.81 in.(14.76 cm)depth. • <br /> kler Supervisory)(requires DACT). <br /> • Door: 18.187 in. (46.195 cm) width; 18.40 in. (46.736 cm) EMERGENCY VOIher TeALARM. <br /> height;0.75 in.(1.905 cm)depth. • OT, PSDN (Other Technologies, Packet-switched Data Net- <br /> work). <br /> • Trim ring:Molding width is 0.905 in.(2.299 cm). • IBC 2012,IBC 2009,IBC 2006,IBC 2003,IBC 2000(Seismic). <br /> • Shipping weight(without batteries):36.15 lb.(16.4 kg). • CBC 2007(Seismic). <br /> TEMPERATURE AND HUMIDITY RANGES <br /> This system meets NFPA requirements for operation at 0-49°C/ <br /> 32-120°F and at a relative humidity 93%±2%RH(noncondens- <br /> ing) at 32°C±2°C (90°F±3°F). However,the useful life of the <br /> system's standby batteries and the electronic components may be <br /> adversely affected by extreme temperature ranges and humidity. <br /> Therefore,it is recommended that this system and its peripherals <br /> be installed in an environment with a normal room temperature of <br /> 15-27°C/60-80°F. <br /> AGENCY LISTINGS AND APPROVALS <br /> The listings and approvals below apply to the basic NFS-320 con- IntelliQuadTM, NOTI•FIRE•NETTM, ONYXWorksTM, and SWIFTTM are <br /> trol panel. In some cases, certain modules may not be listed by trademarks; and Acclimate® PIusTM FirstCommand®, FlashScan®, <br /> certain approval agencies, or listing may be in process. Consult Intelligent FAAST®, NOTIFIER®, ONYX®, VeriFire®, and VIEW® are <br /> factory for latest listing status. registered trademarks of Honeywell International Inc. Microsoft® and <br /> Windows are registered trademarks of Microsoft Corporation.IBM®is a <br /> • UL/ULC Listed:S635. registered trademark of IBM Corporation. <br /> • FM Approved. ©2017 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> ISO 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> C E R T F E U We cannot cover all specific applications or anticipate all requirements. <br /> 10110111111111111111111111111111111111111111111111111 <br /> HAMM 8 M INUACIMIIM All specifications are subject to change without notice. <br /> QUALITY SYSTEMS Country of Origin:USA <br /> For more information,contact Notifies Phone:(203)484-7161,FAX:(203)484-7118. <br /> www.notifier.com <br /> Page 6 of 6-DN-7112:N•3/24/17 <br />