Laserfiche WebLink
SPF/RNVIL DUCTILE IRON THREADED FITTINGS (0)A ! <br /> FIG. 3205R <br /> Reducing Tee <br /> 2 <br /> Bt <br /> 3 <br /> Os <br /> A I 1 LISTED APPROVED <br /> For Listings/Approval Details and Limitations, <br /> 1 X 2 X 3 visit our website at vilintl.com or <br /> contact an Anvir Salesales Representative. <br /> FIGURE 3205R - REDUCING TEE MATERIAL SPECIFICATIONS <br /> Nominal Size Max. Dimensions Approx, Dimensions:ASME B16.3 <br /> Working Wt. Each <br /> 1 x 2 x 3 Pressure A B C Material: ASTM A536 Grade 65-45-12 <br /> In.(mm) PSI(k'a) In.(mm) In.(mm) In. (mm) Iii4sPf9) Black <br /> 1 x'/z x 1 500 1.50 1.36 1.50 0.64 <br /> Threads: NPT per ASME B1.20.1 V <br /> 1 max 1 500 1.50 1.45 1.50 0.73Agency Approvals: All ductile iron threaded fittings are <br /> '` "' 31 "Ut/U LC Listed and FM Approved. <br /> 1 x 1 X 500 1.26 1.26 1.36 0.71 <br /> J0 32 00 i; " <br /> 1 X 1 YL 500 1.37 1.37 1.45 0.76 NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe. <br /> 30 34.8 TJerefore,over tightening can cause damage to pipe threads which may cause <br /> leakage.Ductile iron fittings should be tightened approximately three turns beyond <br /> 1 X 1 )%1 500 1.67 1.67 1.58 0.98 hand tight,but no more than four turns. <br /> 3.5U 42 41 4!41 iU 13 , 11 <br /> 1 x 1 x'hT 500 1.80 1.80 1.65 1.16 <br /> ,r ,15 -,) 41,7: 1 <br /> 1'/ax 1 9h` 500 1.34 1.26 1.58 0.82 FIGURE 3205R - REDUCING TEE <br /> i 3.: J4 32.00 -'h ie r- 'Nominal Size Max. Dimensions <br /> 11/4x 1 9. 500 1.45 1.37 1.62 0.90 Working Approx <br /> S) 36 u 3a.80 11 15 ,.i 1 x 2 x 3 Pressure A B C Wt. Each <br /> 1%4 x 1 x 1 500 1.58 1.50 1,67 1.0 <br /> 5" 3t1 0 ; _i r In.(mm) PSI(k'a) In.(mm) tn.(mm) In.(mm) Lbs.(k <br /> 12 <br /> 11A x 1 x1A 500 1.75 1.67 1.75 1.08 1'/4 x Y4 XY4 500 1.45 1.45 1.62 0.92 <br /> 4 3 a 45 ,_,, <br /> 1%4 x 1 xA 500 1.88 1.80 1.82 1.42 1%4 x 1/4 x 1 500 1.58 1.50 1.67 0.95 <br /> 1'/4 x Y4 x%z 500 1.34 1.34 1.58 0.86 VA x 114 x Y2* 500 1.88 1.88 1.82 1.45 <br /> - :(_, . 5 ,,.Y2 <br /> ♦Working Pressure Ratings are for reference only and based on Sch.40 pipe.For the latest ULJULC,and FM pressure ratings p4relschedule,please visit anvilintl.com or contact <br /> your local Anvil Representative. <br /> * Part supplied as"Bull Head Tee". <br /> PROJECT INFORMATION APPROVAL STAMP <br /> Project: Approved <br /> Address: QApproved as noted <br /> Contractor: QNot approved <br /> Engineer: Remarks: <br /> Submittal Date: <br /> Notes 1: <br /> Notes 2: <br /> SPF/DI-1.15 <br />