Laserfiche WebLink
LATITUDEProduct Guide:Latitude'Series Metal Wall Panels <br /> Testing Summary <br /> ASTM E330 Static Air Pressure (FBC TAS 202) <br /> Allowable Negative Wind Pressure,psf <br /> Clip Spacing(inches) <br /> 12 16 18 24 30 32 36 <br /> 22 Gauge Steel 113.90 108.45 105.73 97.55 89.38 86.65 81.20 <br /> 0.040"Aluminum 106.10 97.30 92.90 79.70 66.50 62.10 53.30 <br /> 0.8mm Zinc 113.90 105.52 101.33 88.75 76.18 71.98 63.60 <br /> Notes: <br /> 1.Based on ASTM E330 testing. <br /> 2.A safety factor of 1.65 has been applied to the ultimate load at failure. <br /> 3.Intermediate values have been interpolated between tested clip spacing. <br /> ASTM E283 Air Infiltration <br /> 1.57 PSF 0.05 CFM/SF <br /> 22 Gauge Steel <br /> 6.24 PSF 0.42 CFM/SF <br /> ASTM E331 Water Infiltration <br /> 5 Gallons/Minute per Square Foot <br /> 2.86 PSF No Leakage <br /> 22 Gauge Steel 6.24 PSF No Leakage <br /> 12.0 PSF No Leakage <br /> ASTM E1886/E1996 Large Missile Impact and Cyclic Air Pressure (FBC TAS 201 &203) <br /> 9 lb.SYP 2x4 at 50 ft./sec. <br /> Impact:Panels over 16 GA studs @ 36"o.c.-No Rupture. <br /> 22 Gauge Steel <br /> Cyclic Air Pressure:77 PSF Negative Design Pressure <br /> Product Approvals <br /> FBC:Pending <br /> Miami-Dade:Pending <br /> www.imetco.com I (800)646-3826 Page i 1 / 4 L T CO <br />