My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1525 75TH ST SW CASCADE COFFEE 2025-04-23
>
Address Records
>
75TH ST SW
>
1525
>
CASCADE COFFEE
>
1525 75TH ST SW CASCADE COFFEE 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 10:54:20 AM
Creation date
2/14/2025 1:35:20 PM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1525
Tenant Name
CASCADE COFFEE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
% ECLIPSE ENGINEERING ECLIPSE-ENGINEERING.COM <br /> Project: Cascade Coffee Addition <br /> Project#: 22-10-138 MEZZANINE SEISMIC ANALYSIS <br /> Name: J.Teems <br /> Date: 03/20/23 <br /> Seismic Design Criteria <br /> 1)Occupancy Category D Importance Factor(Section 115) <br /> OC=II <br /> 1=1 <br /> 2.)Regional Spectral Accelerations(Section 114.1) <br /> S,=1.37 <br /> Si=0.486 <br /> 3.)Site Classification(Section 114.2) <br /> Site Class=D-default <br /> 4.)Site Coefficients&MCER Accelerations(Section 114.3) <br /> SMs=1.644 <br /> Sā1=0.882 <br /> 5.)Design Spectral Accelerations(Section 114.4) <br /> Scs=1.096 <br /> Sol=0.588 <br /> 6.)Seismic Design Category(Section 116)' Period Calculations <br /> SDc=D DL W= 15645 lbs (From Risa) <br /> Column= HSS5x5x114 <br /> X Direction <br /> Seismic Design Requirements for Building Structures fx=5180 lbs (From Risa) <br /> deflection x=1808 in (From Risa) <br /> Structural System&Limitations(Section 12.2) T=4.656 sec (Eqn 15.4-6) <br /> Seismic Force-Resisting System= Steel Ordinary Moment Frames(Ulimited Height) <br /> 7!Direction <br /> R=1 Reponse Modification Coefficient fz=5180 lbs (From Risa) <br /> 03,=1 Overstrength Factor deflection z=2.086 in (From Risa) <br /> Ce=1 Deflection Amplification Factor T=5.0011 sec (Eqn 15.4-6) <br /> h,=NL Structual System Height Limit <br /> Seismic Loads-Equivalent Lateral Force Procedure Seismic Force <br /> 1)Fundamental Period(Section 128.2.1) L)Loading <br /> CI=0.028 Floor Dead Load <br /> x=0.800 (Table 12.8-2) Floor Topping=1118"TnG Plywoc -> 3.7 psf <br /> h,=12.50 (Structural Height) Decking=logo steel -> 5.492 psf <br /> T,=0.21 (Approximate Period) Joists=W8x10 -> 3.57 psf <br />⢠T,=4.66 (Calculated Period-Section 15.4.4) Beam=W12x30 ⢠-> 2.22 psf <br /> Misc=HVAC,Electrical -> 5 psf <br /> 20 psf <br /> 2.)Short-Period and Long-Period Transition Periods Floor Live Load used for Seismic <br /> Ts=0.54 Occupancy=Light Storage -> 3126 pot <br /> Ti=6 (Fig 22-15 through 22-20) <br /> 2.)Base Shear <br /> 3.)Seismic Response Coefficient(Section 12.8.11) A=801 sq.ft. <br /> C,=L096 (Eqn 12.8-2) V=5.18 kip 6.47 psf <br /> ,,;,1=0.048 (Eqn 12.8-5) V,ā;,=0.16 kip 0.20 psf (Eqn 14-1) <br /> C:mn2=0.243 (Eqn 12.8-6) <br /> C,,,;,=0.048 H =2.90 kip 3.63 psf <br /> C,,,,,a=0.126 (Eqn 12.8-3) <br /> =0.163 (Eqn 12.8-4) V=A x[(Dead Load)+(Seismic Live Load)]x Cs <br /> 0.126 Hmin=MAX[0.025(D+L)A,Height to Depth Ratio x 2001bs x N] <br /> C,= <br /> Seismic Force of Hoppers(Treated as dead load for seismic) <br /> Hopper weight 1500 lb <br /> Total Hopper weight 6000 lb(4)hoppers <br /> Area Per Hopper 16 sq.ft. <br /> Hopper Area Load-Gravity 93.8 psf <br /> Hopper Area Load-Seismic 11.8 psf <br /> Total Seismic Shear 757.7 lb <br /> MISSOULA.MT WHITEFISH.MT SPOKANE.WE BEND.OR PORTLAND.OR <br /> PH:teem 721-6n3g PH.(408)652dM2 PH:(609)921-7731 PH.(6o1)$888869 PH1603) -1228 4/81 <br />
The URL can be used to link to this page
Your browser does not support the video tag.