My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1525 75TH ST SW CASCADE COFFEE 2025-04-23
>
Address Records
>
75TH ST SW
>
1525
>
CASCADE COFFEE
>
1525 75TH ST SW CASCADE COFFEE 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 10:54:20 AM
Creation date
2/14/2025 1:35:20 PM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1525
Tenant Name
CASCADE COFFEE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON Anchor Designer TM Company: Date: 10/31/2022 <br /> Engineer: Page: 5/5 <br /> Software Project: <br /> Strong-Tie Version 3.0.7947.0 Address: <br /> Phone: <br /> E-mail: <br /> 8.Steel Strength of Anchor in Shear(Sec.17.5.11 <br /> Vsa(lb) /grout 0 Iggrout0Vsa(Ib) <br /> 9930 1.0 0.65 6455 <br /> 10.Concrete Pryout Strength of Anchor in Shear(Sec.17.5.3) <br /> �Vcpg=l kopNcag=f kop(ANc/ANco)Weo,N ed,N Pc,N�cp,NNb(Sec. 17.3.1 &Eq. 17.5.3.1 b) <br /> kcp ANc(in2) ANco(in2) Wec,N Wed,N Wc,N Wcp,N Na(Ib) 0 0Vcpg(Ib) <br /> 2.0 272.25 68.06 0.892 1.000 1.000 1.000 3876 0.70 19359 <br /> 11.Results <br /> Interaction of Tensile and Shear Forces(Sec.17.6.1 <br /> Tension Factored Load,Nua(lb) Design Strength,eNn(lb) Ratio Status <br /> Steel 335 14303 0.02 Pass <br /> • <br /> Concrete breakout 1200 6734 0.18 Pass(Governs) <br /> Pullout 335 1890 0.18 Pass <br /> Shear Factored Load,Vua(Ib) Design Strength,eVn(Ib) Ratio Status <br /> Steel 227 6455 0.04 Pass <br /> Pryout 860 19359 0.04 Pass(Governs) <br /> Interaction check Nua/QNn Vua/q$Vn Combined Ratio Permissible Status <br /> Sec. 17.6..1 0.18 0.00 17.8% 1.0 Pass <br /> 5/8"f CS Strong-Bolt 2,hnom:3.375"(86mm)meets the selected design criteria. <br /> 12.Warnings <br /> -Per designer input,the tensile component of the strength-level earthquake force applied to anchors does not exceed 20 percent of the total <br /> factored anchor tensile force associated with the same load combination.Therefore the ductility requirements of ACI 318 17.2.3.4.2 for tension <br /> need not be satisfied—designer to verify. <br /> -Per designer input,the shear component of the strength-level earthquake force applied to anchors does not exceed 20 percent of the total <br /> factored anchor shear force associated with the same load combination.Therefore the ductility requirements of ACI 318 17.2.3.5.2 for shear <br /> need not be satisfied—designer to verify. <br /> -Designer must exercise own judgement to determine if this design is suitable. <br /> -Refer to manufacturer's product literature for hole cleaning and installation instructions. <br /> Input data and results must be checked for agreement with the existing circumstances,the standards and guidelines must be checked for plausibility. <br /> Simpson Strong-Tie Company Inc. 5956 W.Las Positas Boulevard Pleasanton,CA 94588 Phone:925.560.9000 Fax:925.847.3871 www.strongtie.com <br /> 36/81 <br />
The URL can be used to link to this page
Your browser does not support the video tag.