My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7400 HARDESON RD SUNBELT RENTALS 2025-03-24
>
Address Records
>
HARDESON RD
>
7400
>
SUNBELT RENTALS
>
7400 HARDESON RD SUNBELT RENTALS 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:38:27 PM
Creation date
2/14/2025 1:56:13 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7400
Tenant Name
SUNBELT RENTALS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONCRETE COMPRESSIVE STRENGTH TEST REPORT MAYES I lrerracon <br /> Report Number: M7221748.0002A <br /> Service Date: 11/10/22 20225 Cedar Valley Rd Ste 110 <br /> Report Date: 12/09/22 Revision 1 - 28-day results Lynnwood, WA 98036-6365 <br /> Task: 425-742-9360 <br /> Client Project - M7221748 <br /> Wilcox Construction Sunbelt Everett Wash Bay <br /> Attn: Sean Painter 7400 Hardeson Road <br /> 234 5th Ave S Everett, WA <br /> Edmonds, WA 98020-3425 <br /> Permit No.: B2107-004 <br /> Material Information Sample Information <br /> Specified Strength: 4,500 psi @ 28 days Sample Date: 11/10/22 Sample Time: 0910 <br /> Sampled By: Todd Wirtz <br /> Mix ID: 7 sack 5000 psi Weather Conditions: Partly cloudy <br /> Supplier: Quick&Easy Concrete Accumulative Yards: 7.5 Batch Size (cy): 7.5 <br /> Batch Time: 0900 Plant: Seattle Placement Method: Chute <br /> Truck No.: M9 Ticket No.: N/A Water Added Before (gal): 0 <br /> Water Added After(gal): 0 <br /> Field Test Data Sample Location: Perimeter walls <br /> Test Result Specification Placement Location: Perimeter walls <br /> Slump (in): 5 <br /> Air Content(a/o): <br /> Concrete Temp. (F): 60 50 - 90 <br /> Ambient Temp. (F): 38 <br /> Plastic Unit Wt. (pcf): <br /> Yield (Cu.Yds.): <br /> Laboratory Test Data <br /> Age at Max Comp <br /> Set Spec Cyl. Avg Diam. Area Date Date Test Load Strength Frac Tested <br /> No. ID Cond. (in) (sq in) Received Tested (days) (lbs) (psi) Type By <br /> 1 1 Good 4.00 12.57 11/11/22 11/17/22 7 57,130 4,550 2 AWD <br /> 1 2 Good 3.99 12.5 11/11/22 12/08/22 28 77,600 6,210 2 AWD <br /> 1 3 Good 3.99 12.5 11/11/22 12/08/22 28 74,130 5,930 2 AWD <br /> 1 4 Good 4.00 12.57 11/11/22 12/08/22 28 76,060 6,050 2 AWD <br /> Average (28 days) 6,060 <br /> Initial Cure: Inside Final Cure: Moist Room Sample Description: 4-inch diameter cylinders <br /> Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit <br /> weight. <br /> Note: Reported air content does not include Aggregate Correction Factor(ACF). <br /> Samples Made By: Mayes/Terracon <br /> Services: Special Inspections/ Materials Testing <br /> Mayes/Terracon Rep.: Todd Wirtz <br /> Reported To: <br /> Contractor: Wilcox Construction <br /> Report Distribution: <br /> (1)Wilcox Construction,Sean Painter (1)City of Everett WA,Permit Services Reviewed By: <br /> (1)Mayes Testing Engineers,Inc,Donna (1)Mayes Testing Engineers,Inc,Todd Wirtz rn <br /> Pollard Senior Project Field Manager <br /> Test Methods: ASTM C 31,ASTM C39,ASTM C138,ASTM C143,ASTM C172,ASTM C231,ASTM C1064,ASTM C1231 <br /> The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be <br /> reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and <br /> are not necessarily indicative of the properties of other apparently similar or identical materials. <br /> CRoo01,3-31-22,Rev.7 Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.