Laserfiche WebLink
The comments below were generated from this project's City of Everett Civil Reviewers.All questions shall be routed through this project's Public Works <br /> Reviewer Thad Newport with City of Everett Permit Services (mailto:TNewport@everettwa.gov). <br /> # Document Sht/Pg Reviewer's Comment Designer's Response Initials <br /> 1 Site Plan — This project is within the combined sewer basin and must meet <br /> requirements in Volume I, Section 6-10 of the City's Design & <br /> Construction Standards and Specifications (DCSS). <br /> • Prepare a drainage report using the Small Project <br /> Stormwater Report Template for Combined Area (PDF). <br /> • Update site plan with BMP stormwater facilities selected <br /> from above template. <br /> 2 Site Plan - Show water and sewer connections from mains to house. Callout <br /> proposed meter size and size of service connections. Side sewer <br /> requires cleanout installed at property line per COE detail 601. <br /> 3 Site Plan - Site plan shows gravel driveway.Access to required parking area <br /> to be durable surfacing material. Gravel by itself is not <br /> considered a durable surface as it wears into the mud and tracks <br /> out to the street. Revise surfacing material accordingly. <br /> Page 2 of 2 <br />