Laserfiche WebLink
616 VMC G .O , D <br /> THE POWER OF TOGETHER CATERPILLAR <br /> CERTIFICATE OF COMPLIANCE <br /> SEISMIC DESIGN OF NONSTRUCTURAL COMPONENTS AND SYSTEMS <br /> Certified Product Table: <br /> Model Max Rating[kW] On/Off Tank Length[in.] Width[in.] Height[in.] Max Weight[Ibs] <br /> D250GC 250 I I 78 6,299 <br /> + { 156 I 57 F- <br /> D300GC I 300 I I I I 64 I 5,750 <br /> + I I- ----I- ----[- I- - <br /> D350GC I 350 I Off Tank I I I 1 8,781 <br /> D400GC+ 400 I i 182 i 64 I 8,856 <br /> + I I I I 88 4- <br /> D450 GC I 450 I I I I I 9,718 <br /> + I I I I I- - <br /> D500GC I 500 I I 1 I I 9,826 <br /> 4 I F- -I-- -I I- - <br /> D550GC I 550 I I I I 10,481 <br /> + 196 I 73 1 _ <br /> D600GC I 600 I I I 86 I 10,664 <br /> + }- I- -I- + I- - <br /> D250GC I 250 181 57 93 1 12,040 <br /> + I I I- - <br /> D300GC I 300 I I I 1 12,234 <br /> + I 4- ]- I <br /> D350GC 1 350 On tank 1 15,854 <br /> + 207 I I 101 <br /> D400GC I 400 I I I 64 I I 15,929 <br /> + I I- I- 1- - <br /> D450GC I 450 I I I I 18,774 <br /> + { 234 102 [.. - <br /> D500GC 1 500 I I I I 17,950 <br /> + I I- }-- + l- - <br /> D550GC I 550 I I 196 I 73 I 99 I 19,850 <br /> -I- [ F- + + t - <br /> D600GC I 600 1 261 74 I 103 I 22,077 <br /> I I I I <br /> Group Type SDS(z/h=0) SDS(Z/h=1) Arlex-H ARig-H AFlex-V ARig-V Fp/Wp <br /> Seismic AC156 1.70 0.57 1.70 0.68 1.13 0.45 0.77 <br /> This certification includes the diesel generator set and included factory supplied options.This certification only covers accessoriesand options <br /> directly mounted to the genset.The genset and applicable options shall be installed per the manufacturer supplied seismic <br /> installationinstructions.For a list of certified configurations and options please directly contact the manufacturer.This certification excludes all <br /> non-factory supplied accessories and options,including but not limited toisolation/restraint devices,other electrical/mechanical components <br /> and all connections for electrical,fuel,heating or cooling fluid,or otherpipe/conduit connections and configurations not detailed in the above <br /> charts.Flexibility in the connections must be maintained as to not transmitload into the equipment.Design specials are outside the scope of <br /> this certification. <br /> 0 <br /> l m c VMA 53383 01 C (Revision 0) <br /> Issue Date: Wednesday,July 22,2020 <br /> vMc' • Revision Date: Wednesday,July 22,2020 <br /> Expiration Date: Monday,July 31,2023 <br /> 102S-103387 Rev17 Page 2 of 3 <br /> 2 <br /> 3120 <br />