Laserfiche WebLink
40-55 Rail Yard <br /> Design Criteria and Loads KPFF Project No. 23000208 <br /> CODES AND REFERENCES <br /> • 2021 IBC with City of Everett Amendments <br /> • 2021 IBC Standards <br /> • Design Loads <br /> o ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures <br /> • Concrete Design <br /> o ACI 318-19 Building Code Requirements for Structural Concrete <br /> • Structural Steel Design <br /> o AISC 360-16 Specification for Structural Steel Buildings <br /> o AISC 341-16 Seismic Provisions for Structural Steel Buildings <br /> o AWS D1.4-18 Structural Welding Code - Steel <br /> COMPUTER PROGRAMS USED <br /> • General Analysis and Design <br /> o Enercalc <br /> o ShapeBuilder <br /> • Concrete Analysis and Design <br /> o Enercalc <br /> MATERIALS SPECIFICATIONS AND STRENGTHS <br /> Concrete (normal weight) <br /> Slab-on-Grade, Curbs and Pads = 4,000 psi <br /> Reinforcing Steel <br /> Unless Noted Otherwise ASTM A 615, Grade 60 <br /> Headed Deformed Bars ASTM A 970, Head Type HA <br /> Structural Steel <br /> Wide Flange Shapes ASTM A 992 <br /> Plates, Bars ASTM A 36, typical <br /> Angles, Channels ASTM A 36 <br /> Structural Tubes (HSS) ASTM A 500, Grade C <br /> Structural Bolts ASTM F 3125, Grade A 325 <br /> Anchor Rods ASTM F1554, Grade 36 (uno) <br /> Threaded Rods ASTM A 36 (uno) <br /> Welding Electrodes 70 ksi, low hydrogen, typical <br /> July 20, 2023 <br /> A004 <br />