My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-55 2025-05-28
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-55
>
3003 W CASINO RD BLDG 40-55 2025-05-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2025 11:47:50 AM
Creation date
2/21/2025 10:54:44 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-55
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
231
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Beam on Elastic Foundation Project File:Boeing Rail.ec6 <br /> LIC#:KW-06018139,Build:20.23.05.25 KPFF CONSULTING ENGINEERS SEA (c)ENERCALC INC 1983-2023 <br /> DESCRIPTION: Typical Slab with 250psf <br /> Load Combination Location(ft) ;ending Stress Results (k-ft <br /> Segment Length Span# in Span Mu:Max phi*Mnx Stress Ratic <br /> Span#1 1 27.176 -0.00 214.54 0.00 <br /> +1.20D+0.50L <br /> Span#1 1 27.176 -0.00 214.54 0.00 <br /> +1.20D <br /> Span#1 1 27.176 -0.00 214.54 0.00 <br /> +0.90D <br /> Span#1 1 27.176 -0.00 214.54 0.00 <br /> Overall Maximum Deflections-Unfactored Lo <br /> Load Combination Span Max."-"Defl Location in Span Load Combination Max."+"Defl Location in Span <br /> Span 1 1 0.0325 13.750 0.0000 0.000 <br /> Detailed Shear Information <br /> Span Distance'd' Vu (k) Mu d*Vu/Mu Phi*Vc Comment Phi*Vs Spacing(in) <br /> Load Combination Number (ft) (in) Actual Design (k-ft) (k) (k) Req'd Suggest <br /> +1.20D+1.60L 1 0.00 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 0.32 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 0.65 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 0.97 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 1.29 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 1.62 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 1.94 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 2.26 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 2.59 15.00 0.90 0.90 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 2.91 15.00 0.90 0.90 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 3.24 15.00 0.90 0.90 0.01 1.00 156.46 vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 3.56 15.00 0.90 0.90 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 3.88 15.00 0.89 0.89 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 4.21 15.00 0.89 0.89 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 4.53 15.00 0.89 0.89 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 4.85 15.00 0.89 0.89 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 5.18 15.00 0.89 0.89 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 5.50 15.00 0.89 0.89 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 5.82 15.00 0.89 0.89 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 6.15 15.00 0.89 0.89 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 6.47 15.00 0.89 0.89 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 6.79 15.00 0.89 0.89 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 7.12 15.00 0.90 0.90 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 7.44 15.00 0.90 0.90 0.02 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 7.76 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 8.09 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 8.41 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 8.74 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 9.06 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 9.38 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 9.71 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 10.03 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 10.35 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 10.68 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.00 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.32 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.65 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.97 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 12.29 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 12.62 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 12.94 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +120D+1.60L 1 13.26 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 13.59 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 13.91 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 14.24 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 14.56 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 14.88 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 15.21 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 15.53 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 15.85 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 16.18 15.00 0.90 0.90 0.04 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 16.50 15.00 0.90 0.90 0.04B00 .00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 16.82 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 17.15 15.00 0.90 0.90 0.03 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.