Project Title: <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Beam on Elastic Foundation Project File:Boeing Rail.ec6 <br /> LIC# KW-06018139,Build:20.23.05.25 KPFF CONSULTING ENGINEERS SEA (c)ENERCALC INC 1983-2023 <br /> DESCRIPTION: Typical Slab with Rail Loads <br /> Load Combination Location(ft) ;ending Stress Results (k-ft <br /> Segment Length Span# in Span Mu:Max phi*Mnx Stress Ratic <br /> Span#1 1 10.029 183.61 214.54 0.86 <br /> +1.20D+0.50L <br /> Span#1 1 10.029 57.37 214.54 0.27 <br /> +1.20D <br /> Span#1 1 27.176 -0.00 214.54 0.00 <br /> +0.90D <br /> Span#1 1 27.176 -0.00 214.54 0.00 <br /> Overall Maximum Deflections-Unfactored Lo <br /> Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span <br /> Span 1 1 0.0754 13.750 0.0000 0.000 <br /> Detailed Shear Information <br /> Span Distance'd' Vu (k) Mu d*Vu/Mu Phi*Vc Phi*Vs Spacing(in) <br /> Load Combination Number (ft) (in) Actual Design (k-ft) (k) Comment (k) Req'd Suggest <br /> +0.90D 1 0.00 15.00 0.32 0.32 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +0.90D 1 0.32 15.00 0.32 0.32 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +0.90D 1 0.65 15.00 0.32 0.32 0.00 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 0.97 15.00 0.38 0.38 0.14 1.00 156.46 vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 1.29 15.00 0.71 0.71 0.12 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 1.62 15.00 1.18 1.18 0.01 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 1.94 15.00 1.78 1.78 0.29 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 2.26 15.00 2.52 2.52 0.76 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 2.59 15.00 3.40 3.40 1.47 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 2.91 15.00 4.42 4.42 2.47 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 3.24 15.00 5.57 5.57 3.80 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 3.56 15.00 6.85 6.85 5.50 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 3.88 15.00 8.28 8.28 7.61 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 4.21 15.00 9.84 9.84 10.19 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 4.53 15.00 11.53 11.53 13.27 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 4.85 15.00 13.36 13.36 16.90 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 5.18 15.00 15.33 15.33 21.12 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 5.50 15.00 17.42 17.42 25.98 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 5.82 15.00 19.65 19.65 31.51 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 6.15 15.00 22.01 22.01 37.77 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 6.47 15.00 24.50 24.50 44.79 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 6.79 15.00 27.11 27.11 52.61 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 7.12 15.00 29.85 29.85 61.28 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 7.44 15.00 32.71 32.71 70.84 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 7.76 15.00 35.69 35.69 81.32 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 8.09 15.00 38.78 38.78 92.76 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 8.41 15.00 41.98 41.98 105.20 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 8.74 15.00 45.29 45.29 118.68 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 9.06 15.00 48.69 48.69 133.23 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 9.38 15.00 52.19 52.19 148.88 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 9.71 15.00 55.78 55.78 165.67 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 10.03 15.00 59.44 59.44 183.61 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 10.35 15.00 -39.23 39.23 182.98 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 10.68 15.00 -35.43 35.43 170.18 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.00 15.00 -31.58 31.58 158.62 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.32 15.00 -27.69 27.69 148.30 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.65 15.00 -23.75 23.75 139.24 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 11.97 15.00 -19.78 19.78 131.45 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 12.29 15.00 -15.79 15.79 124.95 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 12.62 15.00 -11.77 11.77 119.74 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 12.94 15.00 -7.74 7.74 115.83 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 13.26 15.00 -3.69 3.69 113.23 0.59 152.14 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 13.59 15.00 0.36 0.36 111.93 0.06 146.60 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 13.91 15.00 4.41 4.41 111.94 0.71 153.41 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 14.24 15.00 8.45 8.45 113.27 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 14.56 15.00 12.48 12.48 115.90 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 14.88 15.00 16.50 16.50 119.83 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 15.21 15.00 20.49 20.49 125.07 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 15.53 15.00 24.46 24.46 131.60 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 15.85 15.00 28.40 28.40 139.41 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 16.18 15.00 32.29 32.29 148.49 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.200+1.60L 1 16.50 15.00 36.14 36.14 158.84601 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 16.82 15.00 39.94 39.94 170.43 .00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br /> +1.20D+1.60L 1 17.15 15.00 43.67 43.67 183.25 1.00 156.46 Vu<PhiVc/2 Not Reqd 0.00 0.00 <br />