Laserfiche WebLink
POST-INSTALLED ANCHORS REPORT rerracon <br /> Report Number: M7231375.0004 <br /> Service Date: 09/22/23 20225 Cedar Valley Rd Ste 110 <br /> Report Date: 09/27/23 Lynnwood,WA 98036-6365 <br /> 425-742-9360 <br /> Client Project <br /> The Boeing Company Boeing Everett Bldg 40-31 Prit Prat Relocation <br /> Attn: David Duffy 3003 W Casino Rd <br /> 3003 W Casino Rd Everett,WA <br /> Everett,WA 98204-1910 <br /> Project Number: M7231375 <br /> Permit No.: B2305-038 (Foundation-Relocation) <br /> General Information <br /> On site for anchor bolt installations at all (4) mat footings locations between grid lines 11.5 and 12.5 and between <br /> Ba and Bc. <br /> The construction documents referenced for this observation include structural drawings S563, 1 S563-1 R, 1 S563- <br /> 2 and 1 S563-3. <br /> Verified all (16) 1-1/2" diameter x 2'8" long galvanized anchor bolts to have 25-1/2" effective embedment depth <br /> and 6-1/2" projection depth above top of mat footing elevation prior to concrete placement scheduled for Saturday, <br /> 09/23/23. <br /> Compliance Statement <br /> Based on our observations and testing, the above noted items appear to be in general accordance with the <br /> project documents. <br /> Services: Special Inspections/Materials Testing <br /> Mayes/Terracon Rep.: Todd Wirtz <br /> Reported To: Washington Patriot Construction <br /> Contractor: Washington Patriot Construction <br /> Report Distribution: <br /> (1)The Boeing Company,David Duffy (1)Mayes Testing Engineers,Inc,Donna <br /> Pollard <br /> (1)Mayes Testing Engineers,Inc,Todd Wirtz Reviewed By: <br /> Barry Tuttle <br /> Project Field Manager <br /> The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be <br /> reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s)referenced and are not <br /> necessarily indicative of the properties of other apparently similar or identical materials. <br /> DM010,04-29-22 Rev.3 Page 1 of 1 <br />